212 related articles for article (PubMed ID: 26172531)
1. Radiofrequency Ablation with an Internally Cooled Monopolar Directional Electrode: Ex Vivo and in Vivo Experimental Studies in the Liver.
Yu MH; Lee JY; Jun SR; Kim KW; Kim SH; Han JK; Choi BI
Radiology; 2016 Feb; 278(2):395-404. PubMed ID: 26172531
[TBL] [Abstract][Full Text] [Related]
2. Switching monopolar radiofrequency ablation technique using multiple, internally cooled electrodes and a multichannel generator: ex vivo and in vivo pilot study.
Lee JM; Han JK; Kim HC; Choi YH; Kim SH; Choi JY; Choi BI
Invest Radiol; 2007 Mar; 42(3):163-71. PubMed ID: 17287646
[TBL] [Abstract][Full Text] [Related]
3. Hepatic radiofrequency ablation: in vivo and ex vivo comparisons of 15-gauge (G) and 17-G internally cooled electrodes.
Song KD; Lee MW; Park HJ; Cha DI; Kang TW; Lee J; Moon JY; Rhim H
Br J Radiol; 2015 Jun; 88(1050):20140497. PubMed ID: 25882688
[TBL] [Abstract][Full Text] [Related]
4. Switching bipolar hepatic radiofrequency ablation using internally cooled wet electrodes: comparison with consecutive monopolar and switching monopolar modes.
Yoon JH; Lee JM; Woo S; Hwang EJ; Hwang I; Choi W; Han JK; Choi BI
Br J Radiol; 2015 Jun; 88(1050):20140468. PubMed ID: 25873479
[TBL] [Abstract][Full Text] [Related]
5. Radiofrequency renal ablation: in vivo comparison of internally cooled, multitined expandable and internally cooled perfusion electrodes.
Lee JM; Han JK; Chang JM; Chung SY; Son KR; Kim SH; Lee JY; Choi BI
J Vasc Interv Radiol; 2006 Mar; 17(3):549-56. PubMed ID: 16567680
[TBL] [Abstract][Full Text] [Related]
6. Optimization of wet radiofrequency ablation using a perfused-cooled electrode: a comparative study in ex vivo bovine livers.
Lee JM; Han JK; Kim SH; Lee JY; Shin KS; Han CJ; Lee MW; Choi JI; Choi BI
Korean J Radiol; 2004; 5(4):250-7. PubMed ID: 15637475
[TBL] [Abstract][Full Text] [Related]
7. Ex vivo experiment of saline-enhanced hepatic bipolar radiofrequency ablation with a perfused needle electrode: comparison with conventional monopolar and simultaneous monopolar modes.
Lee JM; Kim SH; Han JK; Sohn KL; Choi BI
Cardiovasc Intervent Radiol; 2005; 28(3):338-45. PubMed ID: 15789259
[TBL] [Abstract][Full Text] [Related]
8. Hepatic radiofrequency ablation using multiple probes: ex vivo and in vivo comparative studies of monopolar versus multipolar modes.
Lee JM; Han JK; Lee JY; Kim SH; Choi JY; Lee MW; Choi SH; Eo H; Choi BI
Korean J Radiol; 2006; 7(2):106-17. PubMed ID: 16799271
[TBL] [Abstract][Full Text] [Related]
9. Porcine liver: morphologic characteristics and cell viability at experimental radiofrequency ablation with internally cooled electrodes.
Ng KK; Lam CM; Poon RT; Shek TW; Yu WC; To JY; Wo YH; Lau CP; Tang TC; Ho DW; Fan ST
Radiology; 2005 May; 235(2):478-86. PubMed ID: 15798156
[TBL] [Abstract][Full Text] [Related]
10. A comparison of internally water-perfused and cryogenically cooled monopolar and bipolar radiofrequency applicators in ex vivo liver samples.
Rempp H; Mezger D; Voigtlaender M; Scharpf M; Hoffmann R; Pereira PL; Enderle MD; Claussen CD; Clasen S
Acad Radiol; 2014 May; 21(5):661-6. PubMed ID: 24703480
[TBL] [Abstract][Full Text] [Related]
11. Radiofrequency ablation zones in ex vivo bovine and in vivo porcine livers: comparison of the use of internally cooled electrodes and internally cooled wet electrodes.
Cha J; Choi D; Lee MW; Rhim H; Kim YS; Lim HK; Yoon JH; Park CK
Cardiovasc Intervent Radiol; 2009 Nov; 32(6):1235-40. PubMed ID: 19488818
[TBL] [Abstract][Full Text] [Related]
12. Radiofrequency ablation: simultaneous application of multiple electrodes via switching creates larger, more confluent ablations than sequential application in a large animal model.
Brace CL; Sampson LA; Hinshaw JL; Sandhu N; Lee FT
J Vasc Interv Radiol; 2009 Jan; 20(1):118-24. PubMed ID: 19019701
[TBL] [Abstract][Full Text] [Related]
13. An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes.
Lee JM; Han JK; Kim SH; Lee JY; Shin KS; Choi BI
Acta Radiol; 2005 Aug; 46(5):443-51. PubMed ID: 16224916
[TBL] [Abstract][Full Text] [Related]
14. Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.
Clasen S; Schmidt D; Boss A; Dietz K; Kröber SM; Claussen CD; Pereira PL
Radiology; 2006 Mar; 238(3):881-90. PubMed ID: 16424244
[TBL] [Abstract][Full Text] [Related]
15. No-Touch Radiofrequency Ablation: A Comparison of Switching Bipolar and Switching Monopolar Ablation in
Chang W; Lee JM; Lee SM; Han JK
Korean J Radiol; 2017; 18(2):279-288. PubMed ID: 28246508
[TBL] [Abstract][Full Text] [Related]
16. Radiofrequency ablation using a new type of internally cooled electrode with an adjustable active tip: an experimental study in ex vivo bovine and in vivo porcine livers.
Cha J; Kim YS; Rhim H; Lim HK; Choi D; Lee MW
Eur J Radiol; 2011 Mar; 77(3):516-21. PubMed ID: 19800188
[TBL] [Abstract][Full Text] [Related]
17. Radiofrequency ablation with a new perfused-cooled electrode using a single pump: an experimental study in ex vivo bovine liver.
Kim SK; Seo JW
Cardiovasc Intervent Radiol; 2005; 28(6):779-88. PubMed ID: 16187149
[TBL] [Abstract][Full Text] [Related]
18. A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: results in ex vivo and in vivo porcine livers.
Yu J; Liang P; Yu X; Liu F; Chen L; Wang Y
Eur J Radiol; 2011 Jul; 79(1):124-30. PubMed ID: 20047812
[TBL] [Abstract][Full Text] [Related]
19. Dual switching monopolar radiofrequency ablation using a separable clustered electrode: comparison with consecutive and switching monopolar modes in ex vivo bovine livers.
Yoon JH; Lee JM; Han JK; Choi BI
Korean J Radiol; 2013; 14(3):403-11. PubMed ID: 23690705
[TBL] [Abstract][Full Text] [Related]
20. Radiofrequency ablation with a high-power generator: device efficacy in an in vivo porcine liver model.
Brace CL; Laeseke PF; Sampson LA; Frey TM; Mukherjee R; Lee FT
Int J Hyperthermia; 2007 Jun; 23(4):387-94. PubMed ID: 17558738
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]