These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 2619023)

  • 1. Ventilator disconnexion alarm failures. The role of ventilator and breathing system accessories.
    Pryn SJ; Crosse MM
    Anaesthesia; 1989 Dec; 44(12):978-81. PubMed ID: 2619023
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A study of the incorrect use of ventilator disconnection alarms.
    Campbell RM; Sheikh A; Crosse MM
    Anaesthesia; 1996 Apr; 51(4):369-70. PubMed ID: 8686828
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Home ventilator low-pressure alarms fail to detect accidental decannulation with pediatric tracheostomy tubes.
    Kun SS; Nakamura CT; Ripka JF; Davidson Ward SL; Keens TG
    Chest; 2001 Feb; 119(2):562-4. PubMed ID: 11171738
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ventilator Settings to Avoid Nuisance Alarms During Mouthpiece Ventilation.
    Carlucci A; Mattei A; Rossi V; Paracchini E; Raineri SM; Gregoretti C
    Respir Care; 2016 Apr; 61(4):462-7. PubMed ID: 26670472
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Medishield AGS system and servo 900 ventilators. Investigation and remedy of hazard caused by defeat of 'low expired minute volume' alarm.
    Gray WM; Hall RC; Carter KB; Shaw A; Thomson WJ
    Anaesthesia; 1984 Aug; 39(8):790-4. PubMed ID: 6591842
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Temperature variations of respiratory gases during episodes of anesthetic circuit disconnection in controlled ventilation].
    Valero Castell R; Castillo Monsegur J; Bogdanovich Díaz A; Plaza Moral A
    Rev Esp Anestesiol Reanim; 1991; 38(1):55-7. PubMed ID: 2057630
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
    Uchiyama A; Yoshida T; Yamanaka H; Fujino Y
    Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
    Hentschel R; Buntzel J; Guttmann J; Schumann S
    Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vitro evaluation of the influence of neonatal endotracheal tube diameter and length on the work of breathing.
    Miyake F; Suga R; Akiyama T; Namba F
    Paediatr Anaesth; 2018 May; 28(5):458-462. PubMed ID: 29633434
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modified interface between pediatric ventilator and Ayre's T-piece for use in neonates.
    el-Attar AM
    Middle East J Anaesthesiol; 1996 Feb; 13(4):395-403. PubMed ID: 8713634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Battery duration of portable ventilators: effects of control variable, positive end-expiratory pressure, and inspired oxygen concentration.
    Campbell RS; Johannigman JA; Branson RD; Austin PN; Matacia G; Banks GR
    Respir Care; 2002 Oct; 47(10):1173-83. PubMed ID: 12354337
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Frequency, duration and cause of ventilator alarms on a neonatal intensive care unit.
    Belteki G; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2018 Jul; 103(4):F307-F311. PubMed ID: 29079651
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion.
    Kirton OC; DeHaven B; Morgan J; Morejon O; Civetta J
    Chest; 1997 Oct; 112(4):1055-9. PubMed ID: 9377917
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Work of breathing for cuffed and uncuffed pediatric endotracheal tubes in an in vitro lung model setting.
    Thomas J; Weiss M; Cannizzaro V; Both CP; Schmidt AR
    Paediatr Anaesth; 2018 Sep; 28(9):780-787. PubMed ID: 30004614
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of pressure support in compensating for apparatus work.
    Bersten AD; Rutten AJ; Vedig AE
    Anaesth Intensive Care; 1993 Feb; 21(1):67-71. PubMed ID: 8447610
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.
    Ivanov VA
    Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
    El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
    Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model.
    Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
    BMC Anesthesiol; 2016 Jun; 16(1):30. PubMed ID: 27350249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.
    Aerts JG; van den Berg B; Bogaard JM
    Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.