153 related articles for article (PubMed ID: 26191348)
1. Accuracy of endoscopists' estimate of polyp size: A continuous dilemma.
Izzy M; Virk MA; Saund A; Tejada J; Kargoli F; Anand S
World J Gastrointest Endosc; 2015 Jul; 7(8):824-9. PubMed ID: 26191348
[TBL] [Abstract][Full Text] [Related]
2. The pathologic measurement of polyp size is preferable to the endoscopic estimate.
Schoen RE; Gerber LD; Margulies C
Gastrointest Endosc; 1997 Dec; 46(6):492-6. PubMed ID: 9434214
[TBL] [Abstract][Full Text] [Related]
3. Variation in Pathologist Classification of Colorectal Adenomas and Serrated Polyps.
Gourevitch RA; Rose S; Crockett SD; Morris M; Carrell DS; Greer JB; Pai RK; Schoen RE; Mehrotra A
Am J Gastroenterol; 2018 Mar; 113(3):431-439. PubMed ID: 29380819
[TBL] [Abstract][Full Text] [Related]
4. Use of disposable graduated biopsy forceps improves accuracy of polyp size measurements during endoscopy.
Jin HY; Leng Q
World J Gastroenterol; 2015 Jan; 21(2):623-8. PubMed ID: 25605986
[TBL] [Abstract][Full Text] [Related]
5. Diminutive colorectal polyp resection comparing hot and cold snare and cold biopsy forceps polypectomy. Results of a pilot randomized, single-center study (with videos).
Gómez V; Badillo RJ; Crook JE; Krishna M; Diehl NN; Wallace MB
Endosc Int Open; 2015 Feb; 3(1):E76-80. PubMed ID: 26134778
[TBL] [Abstract][Full Text] [Related]
6. Expert endoscopist assessment of colorectal polyp size using virtual scale endoscopy, visual or snare-based estimation: a prospective video-based study.
Popescu Crainic I; Djinbachian R; Rex DK; Barkun A; Shaukat A; East J; Hassan C; Mori Y; Pohl H; Rastogi A; Sharma P; Anderson JC; Taghiakbari M; Medawar E; von Renteln D
Scand J Gastroenterol; 2024 May; 59(5):608-614. PubMed ID: 38333956
[TBL] [Abstract][Full Text] [Related]
7. Usefulness of a novel calibrated hood to determine indications for colon polypectomy: visual estimation of polyp size is not accurate.
Watanabe T; Kume K; Yoshikawa I; Harada M
Int J Colorectal Dis; 2015 Jul; 30(7):933-8. PubMed ID: 25868514
[TBL] [Abstract][Full Text] [Related]
8. Use of a novel polyp "ruler snare" improves estimation of colon polyp size.
Kaz AM; Anwar A; O'Neill DR; Dominitz JA
Gastrointest Endosc; 2016 Apr; 83(4):812-6. PubMed ID: 26382052
[TBL] [Abstract][Full Text] [Related]
9. Sizing of Polyp Illustrations Differs by Endoscopists' Gender and Improves With a Measurement Reference.
Shamsi N; Shaukat A; Halperin-Goldstein S; Colton J
Eval Health Prof; 2020 Dec; 43(4):270-273. PubMed ID: 30929453
[TBL] [Abstract][Full Text] [Related]
10. [Study on accuracy of endoscopic polyp size measurement by disposable graduated biopsy forceps].
Liu P; Zhang X; Lin HP; Jin HJ; Leng Q; Zhang JH; Zhang Y; Yao H; Wu KL
Zhonghua Wei Chang Wai Ke Za Zhi; 2013 Dec; 16(12):1142-5. PubMed ID: 24369393
[TBL] [Abstract][Full Text] [Related]
11. Accuracy in Polyp Size Measurement Among Surgeons, Gastroenterologists, Trainees, and Experts: A Prospective Video-Based Study.
Djinbachian R; Popescu Crainic I; Pioche M; Saito Y; Sethi A; Chiu P; Marks J; Sebajang H; Pawlak K; Chennouf A; Benard F; Ide Y; Dang F; von Renteln D
Am J Gastroenterol; 2024 Mar; 119(3):532-538. PubMed ID: 37713525
[TBL] [Abstract][Full Text] [Related]
12. Measurement system that improves the accuracy of polyp size determined at colonoscopy.
Leng Q; Jin HY
World J Gastroenterol; 2015 Feb; 21(7):2178-82. PubMed ID: 25717254
[TBL] [Abstract][Full Text] [Related]
13. Endoscopic mis-sizing of polyps changes colorectal cancer surveillance recommendations.
Eichenseer PJ; Dhanekula R; Jakate S; Mobarhan S; Melson JE
Dis Colon Rectum; 2013 Mar; 56(3):315-21. PubMed ID: 23392145
[TBL] [Abstract][Full Text] [Related]
14. Cold snare piecemeal resection of colonic and duodenal polyps ≥1 cm.
Choksi N; Elmunzer BJ; Stidham RW; Shuster D; Piraka C
Endosc Int Open; 2015 Oct; 3(5):E508-13. PubMed ID: 26528509
[TBL] [Abstract][Full Text] [Related]
15. The difference in colon polyp size before and after removal.
Morales TG; Sampliner RE; Garewal HS; Fennerty MB; Aickin M
Gastrointest Endosc; 1996 Jan; 43(1):25-8. PubMed ID: 8903813
[TBL] [Abstract][Full Text] [Related]
16. Is in vivo measurement of size of polyps during colonoscopy accurate?
Gopalswamy N; Shenoy VN; Choudhry U; Markert RJ; Peace N; Bhutani MS; Barde CJ
Gastrointest Endosc; 1997 Dec; 46(6):497-502. PubMed ID: 9434215
[TBL] [Abstract][Full Text] [Related]
17. Is forceps more useful than visualization for measurement of colon polyp size?
Kim JH; Park SJ; Lee JH; Kim TO; Kim HJ; Kim HW; Lee SH; Baek DH; Bigs BU
World J Gastroenterol; 2016 Mar; 22(11):3220-6. PubMed ID: 27003999
[TBL] [Abstract][Full Text] [Related]
18. Linked color imaging improves the visibility of various featured colorectal polyps in an endoscopist's visibility and color difference value.
Yoshida N; Naito Y; Yasuda R; Murakami T; Hirose R; Ogiso K; Inada Y; Dohi O; Kamada K; Uchiyama K; Handa O; Konishi H; Rani RA; Kishimoto M; Konishi E; Itoh Y
Int J Colorectal Dis; 2017 Sep; 32(9):1253-1260. PubMed ID: 28725959
[TBL] [Abstract][Full Text] [Related]
19. Endoscopic measurement of polyp size using a novel calibrated hood.
Kume K; Watanabe T; Yoshikawa I; Harada M
Gastroenterol Res Pract; 2014; 2014():714294. PubMed ID: 25093021
[TBL] [Abstract][Full Text] [Related]
20. Can endoscopic submucosal dissection technique be an alternative treatment option for a difficult giant (≥ 30 mm) pedunculated colorectal polyp?
Choi YS; Lee JB; Lee EJ; Lee SH; Suh JP; Lee DH; Kim DS; Youk EG
Dis Colon Rectum; 2013 May; 56(5):660-6. PubMed ID: 23575407
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]