These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 26199494)

  • 21. Effect of die spacer thickness on shear bond strength of porcelain laminate veneers.
    Cho SH; Chang WG; Lim BS; Lee YK
    J Prosthet Dent; 2006 Mar; 95(3):201-8. PubMed ID: 16543017
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of die-spacing on crown retention.
    Carter SM; Wilson PR
    Int J Prosthodont; 1996; 9(1):21-9. PubMed ID: 8630174
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of preparation relief and flow channels on seating full coverage castings during cementation.
    Webb EL; Murray HV; Holland GA; Taylor DF
    J Prosthet Dent; 1983 Jun; 49(6):777-80. PubMed ID: 6348259
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of the amount of excess cement around the margins of cement-retained dental implant restorations: the effect of the cement application method.
    Chee WW; Duncan J; Afshar M; Moshaverinia A
    J Prosthet Dent; 2013 Apr; 109(4):216-21. PubMed ID: 23566601
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations.
    Bernal G; Okamura M; Muñoz CA
    J Prosthodont; 2003 Jun; 12(2):111-5. PubMed ID: 12964683
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An In-vitro Comparative Stereomicroscopic Analysis and Evaluation of Marginal Accuracy in Porcelain Fused to Metal Copings Fabricated in Two Different Finish Lines Using Variant Die Materials.
    Vaswani PL; Sanyal PK; Gosavi SY; Kore AR
    J Clin Diagn Res; 2017 Jan; 11(1):ZC01-ZC05. PubMed ID: 28274033
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation.
    Wang CJ; Millstein PL; Nathanson D
    J Prosthet Dent; 1992 Jun; 67(6):786-90. PubMed ID: 1403860
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: Milling, stereolithography, and 3D wax printer.
    Khaledi AA; Farzin M; Akhlaghian M; Pardis S; Mir N
    J Prosthet Dent; 2020 Jul; 124(1):81-86. PubMed ID: 31672421
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of the Use of Die Lubricant on the Marginal Fit of Wax Patterns.
    Wagh A; Gandhewar M; Pawar P; Chavan A; Kharwade S; Mendhe A; Singh D
    J Pharm Bioallied Sci; 2021 Nov; 13(Suppl 2):S1115-S1118. PubMed ID: 35017941
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Influence of finish-line form on crown cementation.
    Byrne G
    Int J Prosthodont; 1992; 5(2):137-44. PubMed ID: 1524634
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of finish line on marginal fit of sintered gold copings.
    Gwinner FP; Bottino MA; Nogueira-Junior L; Della Bona A
    Braz Dent J; 2013; 24(4):322-5. PubMed ID: 24173248
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of die relief on the seating, fit and retention of cast gold crowns cemented on human teeth.
    Lee HH; Ibbetson RJ
    Singapore Dent J; 2000 Feb; 23(1):6-11. PubMed ID: 11602954
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of Film Thickness of Crown Disclosing Agents and Their Comparison with Cement Film Thickness after Final Cementation.
    Habib SR; Ansari AS; Bajunaid SO; Alshahrani A; Javed MQ
    Eur J Dent; 2020 Mar; 14(2):224-232. PubMed ID: 32375183
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A mathematical treatise on the fit of crown castings.
    Grajower R; Lewinstein I
    J Prosthet Dent; 1983 May; 49(5):663-74. PubMed ID: 6574235
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The effect of endodontic access preparation on the failure load of lithium disilicate glass-ceramic restorations.
    Qeblawi D; Hill T; Chlosta K
    J Prosthet Dent; 2011 Nov; 106(5):328-36. PubMed ID: 22024183
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The influence of auxiliary features on the resistance form of short molars prepared for complete cast crowns.
    Roudsari RV; Satterthwaite JD
    J Prosthet Dent; 2011 Nov; 106(5):305-9. PubMed ID: 22024180
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Factors affecting the retention and fit of gold castings.
    Marker VA; Miller AW; Miller BH; Swepston JH
    J Prosthet Dent; 1987 Apr; 57(4):425-30. PubMed ID: 3553565
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of porcelain firing and cementation on the marginal adaptation of metal-ceramic restorations prepared by different methods.
    Kaleli N; Saraç D
    J Prosthet Dent; 2017 May; 117(5):656-661. PubMed ID: 27881325
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Low force cementation.
    Wilson PR
    J Dent; 1996 Jul; 24(4):269-73. PubMed ID: 8783532
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of the fit of zirconia copings fabricated by direct and indirect digital scanning procedures.
    Lee B; Oh KC; Haam D; Lee JH; Moon HS
    J Prosthet Dent; 2018 Aug; 120(2):225-231. PubMed ID: 29428522
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.