These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

304 related articles for article (PubMed ID: 26204135)

  • 1. Adjustment of Open-Loop Settings to Improve Closed-Loop Results in Type 1 Diabetes: A Multicenter Randomized Trial.
    Dassau E; Brown SA; Basu A; Pinsker JE; Kudva YC; Gondhalekar R; Patek S; Lv D; Schiavon M; Lee JB; Dalla Man C; Hinshaw L; Castorino K; Mallad A; Dadlani V; McCrady-Spitzer SK; McElwee-Malloy M; Wakeman CA; Bevier WC; Bradley PK; Kovatchev B; Cobelli C; Zisser HC; Doyle FJ
    J Clin Endocrinol Metab; 2015 Oct; 100(10):3878-86. PubMed ID: 26204135
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Overnight Closed-Loop Control Improves Glycemic Control in a Multicenter Study of Adults With Type 1 Diabetes.
    Brown SA; Breton MD; Anderson SM; Kollar L; Keith-Hynes P; Levy CJ; Lam DW; Levister C; Baysal N; Kudva YC; Basu A; Dadlani V; Hinshaw L; McCrady-Spitzer S; Bruttomesso D; Visentin R; Galasso S; Del Favero S; Leal Y; Boscari F; Avogaro A; Cobelli C; Kovatchev BP
    J Clin Endocrinol Metab; 2017 Oct; 102(10):3674-3682. PubMed ID: 28666360
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multinight "bedside" closed-loop control for patients with type 1 diabetes.
    Brown SA; Kovatchev BP; Breton MD; Anderson SM; Keith-Hynes P; Patek SD; Jiang B; Ben Brahim N; Vereshchetin P; Bruttomesso D; Avogaro A; Del Favero S; Boscari F; Galasso S; Visentin R; Monaro M; Cobelli C
    Diabetes Technol Ther; 2015 Mar; 17(3):203-9. PubMed ID: 25594434
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multinational Home Use of Closed-Loop Control Is Safe and Effective.
    Anderson SM; Raghinaru D; Pinsker JE; Boscari F; Renard E; Buckingham BA; Nimri R; Doyle FJ; Brown SA; Keith-Hynes P; Breton MD; Chernavvsky D; Bevier WC; Bradley PK; Bruttomesso D; Del Favero S; Calore R; Cobelli C; Avogaro A; Farret A; Place J; Ly TT; Shanmugham S; Phillip M; Dassau E; Dasanayake IS; Kollman C; Lum JW; Beck RW; Kovatchev B;
    Diabetes Care; 2016 Jul; 39(7):1143-50. PubMed ID: 27208316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Safety of outpatient closed-loop control: first randomized crossover trials of a wearable artificial pancreas.
    Kovatchev BP; Renard E; Cobelli C; Zisser HC; Keith-Hynes P; Anderson SM; Brown SA; Chernavvsky DR; Breton MD; Mize LB; Farret A; Place J; Bruttomesso D; Del Favero S; Boscari F; Galasso S; Avogaro A; Magni L; Di Palma F; Toffanin C; Messori M; Dassau E; Doyle FJ
    Diabetes Care; 2014 Jul; 37(7):1789-96. PubMed ID: 24929429
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fully artificial pancreas versus a hybrid artificial pancreas for type 1 diabetes: a single-centre, open-label, randomised controlled, crossover, non-inferiority trial.
    Tsoukas MA; Majdpour D; Yale JF; Fathi AE; Garfield N; Rutkowski J; Rene J; Legault L; Haidar A
    Lancet Digit Health; 2021 Nov; 3(11):e723-e732. PubMed ID: 34580055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Randomized Outpatient Trial of Single- and Dual-Hormone Closed-Loop Systems That Adapt to Exercise Using Wearable Sensors.
    Castle JR; El Youssef J; Wilson LM; Reddy R; Resalat N; Branigan D; Ramsey K; Leitschuh J; Rajhbeharrysingh U; Senf B; Sugerman SM; Gabo V; Jacobs PG
    Diabetes Care; 2018 Jul; 41(7):1471-1477. PubMed ID: 29752345
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Manual Closed-Loop Insulin Delivery Using a Saddle Point Model Predictive Control Algorithm: Results of a Crossover Randomized Overnight Study.
    Guilhem I; Penet M; Paillard A; Carpentier M; Esvant A; Lefebvre MA; Poirier JY
    J Diabetes Sci Technol; 2017 Sep; 11(5):1007-1014. PubMed ID: 28677416
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MD-Logic overnight type 1 diabetes control in home settings: A multicentre, multinational, single blind randomized trial.
    Nimri R; Bratina N; Kordonouri O; Avbelj Stefanija M; Fath M; Biester T; Muller I; Atlas E; Miller S; Fogel A; Phillip M; Danne T; Battelino T
    Diabetes Obes Metab; 2017 Apr; 19(4):553-561. PubMed ID: 27981804
    [TBL] [Abstract][Full Text] [Related]  

  • 10. DREAM5: An open-label, randomized, cross-over study to evaluate the safety and efficacy of day and night closed-loop control by comparing the MD-Logic automated insulin delivery system to sensor augmented pump therapy in patients with type 1 diabetes at home.
    Biester T; Nir J; Remus K; Farfel A; Muller I; Biester S; Atlas E; Dovc K; Bratina N; Kordonouri O; Battelino T; Philip M; Danne T; Nimri R
    Diabetes Obes Metab; 2019 Apr; 21(4):822-828. PubMed ID: 30478937
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study.
    Leelarathna L; Dellweg S; Mader JK; Allen JM; Benesch C; Doll W; Ellmerer M; Hartnell S; Heinemann L; Kojzar H; Michalewski L; Nodale M; Thabit H; Wilinska ME; Pieber TR; Arnolds S; Evans ML; Hovorka R;
    Diabetes Care; 2014 Jul; 37(7):1931-7. PubMed ID: 24963110
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies.
    Hovorka R; Kumareswaran K; Harris J; Allen JM; Elleri D; Xing D; Kollman C; Nodale M; Murphy HR; Dunger DB; Amiel SA; Heller SR; Wilinska ME; Evans ML
    BMJ; 2011 Apr; 342():d1855. PubMed ID: 21493665
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery.
    Kovatchev B; Cheng P; Anderson SM; Pinsker JE; Boscari F; Buckingham BA; Doyle FJ; Hood KK; Brown SA; Breton MD; Chernavvsky D; Bevier WC; Bradley PK; Bruttomesso D; Del Favero S; Calore R; Cobelli C; Avogaro A; Ly TT; Shanmugham S; Dassau E; Kollman C; Lum JW; Beck RW
    Diabetes Technol Ther; 2017 Jan; 19(1):18-24. PubMed ID: 27982707
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Home Use of Day-and-Night Hybrid Closed-Loop Insulin Delivery in Very Young Children: A Multicenter, 3-Week, Randomized Trial.
    Tauschmann M; Allen JM; Nagl K; Fritsch M; Yong J; Metcalfe E; Schaeffer D; Fichelle M; Schierloh U; Thiele AG; Abt D; Kojzar H; Mader JK; Slegtenhorst S; Barber N; Wilinska ME; Boughton C; Musolino G; Sibayan J; Cohen N; Kollman C; Hofer SE; Fröhlich-Reiterer E; Kapellen TM; Acerini CL; de Beaufort C; Campbell F; Rami-Merhar B; Hovorka R;
    Diabetes Care; 2019 Apr; 42(4):594-600. PubMed ID: 30692242
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Day-and-Night Closed-Loop Insulin Delivery in a Broad Population of Pregnant Women With Type 1 Diabetes: A Randomized Controlled Crossover Trial.
    Stewart ZA; Wilinska ME; Hartnell S; O'Neil LK; Rayman G; Scott EM; Barnard K; Farrington C; Hovorka R; Murphy HR
    Diabetes Care; 2018 Jul; 41(7):1391-1399. PubMed ID: 29535135
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial.
    Nimri R; Muller I; Atlas E; Miller S; Fogel A; Bratina N; Kordonouri O; Battelino T; Danne T; Phillip M
    Diabetes Care; 2014 Nov; 37(11):3025-32. PubMed ID: 25078901
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fully Closed-Loop Multiple Model Probabilistic Predictive Controller Artificial Pancreas Performance in Adolescents and Adults in a Supervised Hotel Setting.
    Forlenza GP; Cameron FM; Ly TT; Lam D; Howsmon DP; Baysal N; Kulina G; Messer L; Clinton P; Levister C; Patek SD; Levy CJ; Wadwa RP; Maahs DM; Bequette BW; Buckingham BA
    Diabetes Technol Ther; 2018 May; 20(5):335-343. PubMed ID: 29658779
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated hybrid closed-loop control with a proportional-integral-derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance.
    Ly TT; Weinzimer SA; Maahs DM; Sherr JL; Roy A; Grosman B; Cantwell M; Kurtz N; Carria L; Messer L; von Eyben R; Buckingham BA
    Pediatr Diabetes; 2017 Aug; 18(5):348-355. PubMed ID: 27191182
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Psychosocial aspects of closed- and open-loop insulin delivery: closing the loop in adults with Type 1 diabetes in the home setting.
    Barnard KD; Wysocki T; Thabit H; Evans ML; Amiel S; Heller S; Young A; Hovorka R;
    Diabet Med; 2015 May; 32(5):601-8. PubMed ID: 25615888
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Day and night glycaemic control with a bionic pancreas versus conventional insulin pump therapy in preadolescent children with type 1 diabetes: a randomised crossover trial.
    Russell SJ; Hillard MA; Balliro C; Magyar KL; Selagamsetty R; Sinha M; Grennan K; Mondesir D; Ekhlaspour L; Zheng H; Damiano ER; El-Khatib FH
    Lancet Diabetes Endocrinol; 2016 Mar; 4(3):233-243. PubMed ID: 26850709
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.