These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

66 related articles for article (PubMed ID: 26204389)

  • 1. Concurrent high-sensitivity conductometric detection of volatile weak acids in a suppressed anion chromatography system.
    Liao H; Kadjo AF; Dasgupta PK
    Anal Chem; 2015 Aug; 87(16):8342-6. PubMed ID: 26204389
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Permeative Amine Introduction for Very Weak Acid Detection in Ion Chromatography.
    Liao H; Dasgupta PK
    Anal Chem; 2016 Feb; 88(4):2198-204. PubMed ID: 26815767
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Conductometric Gradient Ion Exclusion Chromatography for Volatile Fatty Acids.
    Shelor CP; Dasgupta PK; Liao H
    Anal Chem; 2016 Dec; 88(24):12323-12329. PubMed ID: 28193054
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous flame ionization and absorbance detection of volatile and nonvolatile compounds by reversed-phase liquid chromatography with a water mobile phase.
    Bruckner CA; Ecker ST; Synovec RE
    Anal Chem; 1997 Sep; 69(17):3465-70. PubMed ID: 21639269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Water ICE: Ion Exclusion Chromatography of Very Weak Acids with a Pure Water Eluent.
    Liao H; Shelor CP; Dasgupta PK
    Anal Chem; 2016 May; 88(9):4965-70. PubMed ID: 27075932
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Two-Dimensional detection in ion chromatography: sequential conductometry after suppression and passive hydroxide introduction.
    Al-Horr R; Dasgupta PK; Adams RL
    Anal Chem; 2001 Oct; 73(19):4694-703. PubMed ID: 11605849
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Admittance detector for high impedance systems: design and applications.
    Zhang M; Stamos BN; Dasgupta PK
    Anal Chem; 2014 Dec; 86(23):11547-53. PubMed ID: 25354912
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Carbonic Acid Eluent Ion Chromatography.
    Sricharoen P; Limchoowong N; Shelor CP; Dasgupta PK
    Anal Chem; 2019 Mar; 91(5):3636-3644. PubMed ID: 30719920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Postcolumn concentration in liquid chromatography. On-line eluent evaporation and analyte postconcentration in ion chromatography.
    Takeuchi M; Dasgupta PK; Dyke JV; Srinivasan K
    Anal Chem; 2007 Aug; 79(15):5690-7. PubMed ID: 17608451
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Conductometric detection of anions of weak acids in chemically suppressed ion chromatography:  critical point concentrations.
    Caliamanis A; McCormick MJ; Carpenter PD
    Anal Chem; 1999 Feb; 71(3):741-6. PubMed ID: 21662725
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mixing characteristics of mixers in flow analysis. Application to two-dimensional detection in ion chromatography.
    Liao H; Dasgupta PK; Srinivasan K; Liu Y
    Anal Chem; 2015 Jan; 87(1):793-800. PubMed ID: 25426864
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of low-molecular-mass aliphatic carboxylic acids and inorganic anions from kraft black liquors by ion chromatography.
    Käkölä JM; Alén RJ; Isoaho JP; Matilainen RB
    J Chromatogr A; 2008 May; 1190(1-2):150-6. PubMed ID: 18374929
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Selective detection of volatile aromatic compounds using a compact laser ionization detector with fast gas chromatography.
    Meyer MJ; Schieffer GM; Moeker EK; Brodersen JJ; Swenson OF; Borgerding AJ
    Anal Chem; 2004 Mar; 76(6):1702-7. PubMed ID: 15018571
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous separation and detection of anions and thiophilic cations using capillary-size anion exchange chromatography with suppressed conductivity detection.
    Sötz VA; Kochmann S
    J Sep Sci; 2015 May; 38(8):1301-9. PubMed ID: 25676801
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Determination of blood cyanide using head-space gas chromatography with electron capture detection].
    Maseda C; Matsubara K; Hasegawa M; Akane A; Shiono H
    Nihon Hoigaku Zasshi; 1990 Apr; 44(2):131-6. PubMed ID: 2169555
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of amino acid isotope enrichment using liquid chromatography-mass spectrometry.
    van Eijk HM; Rooyakkers DR; Soeters PB; Deutz NE
    Anal Biochem; 1999 Jun; 271(1):8-17. PubMed ID: 10360999
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ion chromatographic determination of trace iodate, chlorite, chlorate, bromide, bromate and nitrite in drinking water using suppressed conductivity detection and visible detection.
    Binghui Z; Zhixiong Z; Jing Y
    J Chromatogr A; 2006 Jun; 1118(1):106-10. PubMed ID: 16597441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Dual Membrane Electrodialytic Phosphoric Acid Eluent Generator for Ion Exclusion Chromatography-A Gas-Free Electrodialytic Phosphoric Acid Generator.
    Sun X; Tang J; Chen W; Zhang F; Yang B
    J Sep Sci; 2024 Sep; 47(18):e202400536. PubMed ID: 39302689
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of a constant current charge detector.
    Mori M; Chen Y; Ohira S; Dasgupta PK
    Talanta; 2012 Dec; 102():44-52. PubMed ID: 23182573
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Latex-coated polymeric monolithic ion-exchange stationary phases. 2. Micro-ion chromatography.
    Zakaria P; Hutchinson JP; Avdalovic N; Liu Y; Haddad PR
    Anal Chem; 2005 Jan; 77(2):417-23. PubMed ID: 15649036
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]