These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Lag screw fixation of medial malleolar fractures: a biomechanical, radiographic, and clinical comparison of unicortical partially threaded lag screws and bicortical fully threaded lag screws. Ricci WM; Tornetta P; Borrelli J J Orthop Trauma; 2012 Oct; 26(10):602-6. PubMed ID: 22437423 [TBL] [Abstract][Full Text] [Related]
3. Comparison of pullout strength between 3.5-mm fully threaded, bicortical screws and 4.0-mm partially threaded, cancellous screws in the fixation of medial malleolar fractures. Pollard JD; Deyhim A; Rigby RB; Dau N; King C; Fallat LM; Bir C J Foot Ankle Surg; 2010; 49(3):248-52. PubMed ID: 20362467 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fractures. Schaefer TK; Spross C; Stoffel KK; Yates PJ Injury; 2015 Nov; 46(11):2130-3. PubMed ID: 26342555 [TBL] [Abstract][Full Text] [Related]
5. Biomechanical Comparison of Fully Threaded Solid Cortical Versus Partially Threaded Cannulated Cancellous Screw Fixation for Lisfranc Injuries. Rozell JC; Chin M; Donegan DJ; Hast MW Orthopedics; 2018 Mar; 41(2):e222-e227. PubMed ID: 29309714 [TBL] [Abstract][Full Text] [Related]
6. The effect of screw thread length on initial stability of Schatzker type 1 tibial plateau fracture fixation: a biomechanical study. Salduz A; Birisik F; Polat G; Bekler B; Bozdag E; Kilicoglu O J Orthop Surg Res; 2016 Nov; 11(1):146. PubMed ID: 27876042 [TBL] [Abstract][Full Text] [Related]
7. Is just one screw really enough? Single- versus double-screw in the medial malleolus in supination-external rotation ankle fractures: A comparative biomechanical study using partially threaded cancellous screws. Giordano V; Rodrigues A; Voelcker L; Alves G; Pires RE; Freitas A; Mariolani JR; Belangero WD Injury; 2024 Feb; 55(2):111175. PubMed ID: 37926664 [TBL] [Abstract][Full Text] [Related]
8. Biomechanical comparison of a fully threaded, variable pitch screw and a partially threaded lag screw for internal fixation of Type II dens fractures. Magee W; Hettwer W; Badra M; Bay B; Hart R Spine (Phila Pa 1976); 2007 Aug; 32(17):E475-9. PubMed ID: 17762280 [TBL] [Abstract][Full Text] [Related]
9. Biomechanical Evaluation of Plate Versus Lag Screw Only Fixation of Distal Fibula Fractures. Misaghi A; Doan J; Bastrom T; Pennock AT J Foot Ankle Surg; 2015; 54(5):896-9. PubMed ID: 25990534 [TBL] [Abstract][Full Text] [Related]
10. Jones fracture fixation: a biomechanical comparison of partially threaded screws versus tapered variable pitch screws. Orr JD; Glisson RR; Nunley JA Am J Sports Med; 2012 Mar; 40(3):691-8. PubMed ID: 22227846 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of a new method of small fragment fixation in a medial malleolus fracture model. Rovinsky D; Haskell A; Liu Q; Paiement GD; Robinovitch S J Orthop Trauma; 2000 Aug; 14(6):420-5. PubMed ID: 11001416 [TBL] [Abstract][Full Text] [Related]
12. Comparison of plate and screw fixation and screw fixation alone in a comminuted talar neck fracture model. Charlson MD; Parks BG; Weber TG; Guyton GP Foot Ankle Int; 2006 May; 27(5):340-3. PubMed ID: 16701054 [TBL] [Abstract][Full Text] [Related]