125 related articles for article (PubMed ID: 26216174)
1. Development of virtual patient models for permanent implant brachytherapy Monte Carlo dose calculations: interdependence of CT image artifact mitigation and tissue assignment.
Miksys N; Xu C; Beaulieu L; Thomson RM
Phys Med Biol; 2015 Aug; 60(15):6039-62. PubMed ID: 26216174
[TBL] [Abstract][Full Text] [Related]
2. Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy.
Sutherland JG; Miksys N; Furutani KM; Thomson RM
Med Phys; 2014 Jan; 41(1):011712. PubMed ID: 24387504
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for
Assam I; Vijande J; Ballester F; Pérez-Calatayud J; Poppe B; Siebert FA
Med Phys; 2022 Sep; 49(9):6195-6208. PubMed ID: 35925023
[TBL] [Abstract][Full Text] [Related]
4. Patient-specific Monte Carlo dose calculations for (103)Pd breast brachytherapy.
Miksys N; Cygler JE; Caudrelier JM; Thomson RM
Phys Med Biol; 2016 Apr; 61(7):2705-29. PubMed ID: 26976478
[TBL] [Abstract][Full Text] [Related]
5. Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.
Côté N; Bedwani S; Carrier JF
Med Phys; 2016 May; 43(5):2611. PubMed ID: 27147370
[TBL] [Abstract][Full Text] [Related]
6. Large-scale Retrospective Monte Carlo Dosimetric Study for Permanent Implant Prostate Brachytherapy.
Miksys N; Vigneault E; Martin AG; Beaulieu L; Thomson RM
Int J Radiat Oncol Biol Phys; 2017 Mar; 97(3):606-615. PubMed ID: 28126308
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric and radiobiological investigation of permanent implant prostate brachytherapy based on Monte Carlo calculations.
Haidari AM; Miksys N; Soubiran P; Cygler JE; Holmes O; Perry G; Thomson RM
Brachytherapy; 2019; 18(6):875-882. PubMed ID: 31400953
[TBL] [Abstract][Full Text] [Related]
8. Model-based dose calculations for (125)I lung brachytherapy.
Sutherland JG; Furutani KM; Garces YI; Thomson RM
Med Phys; 2012 Jul; 39(7):4365-77. PubMed ID: 22830769
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric impact of dual-energy CT tissue segmentation for low-energy prostate brachytherapy: a Monte Carlo study.
Remy C; Lalonde A; Béliveau-Nadeau D; Carrier JF; Bouchard H
Phys Med Biol; 2018 Jan; 63(2):025013. PubMed ID: 29260727
[TBL] [Abstract][Full Text] [Related]
10. An algorithm for efficient metal artifact reductions in permanent seed.
Xu C; Verhaegen F; Laurendeau D; Enger SA; Beaulieu L
Med Phys; 2011 Jan; 38(1):47-56. PubMed ID: 21361174
[TBL] [Abstract][Full Text] [Related]
11. Coupling I-125 permanent implant prostate brachytherapy Monte Carlo dose calculations with radiobiological models.
Miksys N; Haidari M; Vigneault E; Martin AG; Beaulieu L; Thomson RM
Med Phys; 2017 Aug; 44(8):4329-4340. PubMed ID: 28455849
[TBL] [Abstract][Full Text] [Related]
12. Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant.
Furstoss C; Reniers B; Bertrand MJ; Poon E; Carrier JF; Keller BM; Pignol JP; Beaulieu L; Verhaegen F
Med Phys; 2009 May; 36(5):1848-58. PubMed ID: 19544804
[TBL] [Abstract][Full Text] [Related]
13. Changes realized from extended bit-depth and metal artifact reduction in CT.
Glide-Hurst C; Chen D; Zhong H; Chetty IJ
Med Phys; 2013 Jun; 40(6):061711. PubMed ID: 23718590
[TBL] [Abstract][Full Text] [Related]
14. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition.
Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F
Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752
[TBL] [Abstract][Full Text] [Related]
15. Investigation of interseed attenuation and tissue composition effects in (125)I seed implant prostate brachytherapy.
Mason J; Al-Qaisieh B; Bownes P; Henry A; Thwaites D
Brachytherapy; 2014; 13(6):603-10. PubMed ID: 24913435
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of two commercial CT metal artifact reduction algorithms for use in proton radiotherapy treatment planning in the head and neck area.
Andersson KM; Dahlgren CV; Reizenstein J; Cao Y; Ahnesjö A; Thunberg P
Med Phys; 2018 Oct; 45(10):4329-4344. PubMed ID: 30076784
[TBL] [Abstract][Full Text] [Related]
17. Correction of CT artifacts and its influence on Monte Carlo dose calculations.
Bazalova M; Beaulieu L; Palefsky S; Verhaegena F
Med Phys; 2007 Jun; 34(6):2119-32. PubMed ID: 17654915
[TBL] [Abstract][Full Text] [Related]
18. Generation of hybrid sinograms for the recovery of kV-CT images with metal artifacts for helical tomotherapy.
Jeon H; Park D; Youn H; Nam J; Lee J; Kim W; Ki Y; Kim YH; Lee JH; Kim D; Kim HK
Med Phys; 2015 Aug; 42(8):4654-67. PubMed ID: 26233193
[TBL] [Abstract][Full Text] [Related]
19. Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm.
Abdoli M; Ay MR; Ahmadian A; Dierckx RA; Zaidi H
Med Phys; 2010 Dec; 37(12):6166-77. PubMed ID: 21302773
[TBL] [Abstract][Full Text] [Related]
20. A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy.
Ali I; Algan O; Thompson S; Sindhwani P; Herman T; Cheng CY; Ahmad S
Phys Med Biol; 2009 Sep; 54(18):5595-611. PubMed ID: 19717887
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]