BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 26218439)

  • 1. Robust algorithm to locate heart beats from multiple physiological waveforms by individual signal detector voting.
    Galeotti L; Scully CG; Vicente J; Johannesen L; Strauss DG
    Physiol Meas; 2015 Aug; 36(8):1705-16. PubMed ID: 26218439
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach.
    Antink CH; Brüser C; Leonhardt S
    Physiol Meas; 2015 Aug; 36(8):1679-90. PubMed ID: 26218172
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust detection of heart beats in multimodal records using slope- and peak-sensitive band-pass filters.
    Pangerc U; Jager F
    Physiol Meas; 2015 Aug; 36(8):1645-64. PubMed ID: 26217963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Robust detection of heart beats in multimodal data.
    Silva I; Moody B; Behar J; Johnson A; Oster J; Clifford GD; Moody GB
    Physiol Meas; 2015 Aug; 36(8):1629-44. PubMed ID: 26217894
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heart beat detection in multimodal physiological data using a hidden semi-Markov model and signal quality indices.
    A F Pimentel M; Santos MD; Springer DB; Clifford GD
    Physiol Meas; 2015 Aug; 36(8):1717-27. PubMed ID: 26218536
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heart beat detection using a multimodal data coupling method.
    Mollakazemi MJ; Atyabi SA; Ghaffari A
    Physiol Meas; 2015 Aug; 36(8):1729-42. PubMed ID: 26218667
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multimodal heart beat detection using signal quality indices.
    Johnson AE; Behar J; Andreotti F; Clifford GD; Oster J
    Physiol Meas; 2015 Aug; 36(8):1665-77. PubMed ID: 26218060
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel algorithm for reducing false arrhythmia alarms in intensive care units.
    Srivastava C; Sharma S; Jalali A
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():2525-2528. PubMed ID: 28268837
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction of false arrhythmia alarms using signal selection and machine learning.
    Eerikäinen LM; Vanschoren J; Rooijakkers MJ; Vullings R; Aarts RM
    Physiol Meas; 2016 Aug; 37(8):1204-16. PubMed ID: 27454128
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Heart beat detection in multimodal data using automatic relevant signal detection.
    De Cooman T; Goovaerts G; Varon C; Widjaja D; Willemen T; Van Huffel S
    Physiol Meas; 2015 Aug; 36(8):1691-704. PubMed ID: 26218307
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Robust heartbeat detection using multimodal recordings and ECG quality assessment with signal amplitudes dispersion.
    Khavas ZR; Asl BM
    Comput Methods Programs Biomed; 2018 Sep; 163():169-182. PubMed ID: 30119851
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A practical algorithm to reduce false critical ECG alarms using arterial blood pressure and/or photoplethysmogram waveforms.
    Zong W; Nielsen L; Gross B; Brea J; Frassica J
    Physiol Meas; 2016 Aug; 37(8):1355-69. PubMed ID: 27455375
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Extracting fetal heart beats from maternal abdominal recordings: selection of the optimal principal components.
    Di Maria C; Liu C; Zheng D; Murray A; Langley P
    Physiol Meas; 2014 Aug; 35(8):1649-64. PubMed ID: 25069769
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detection of false arrhythmia alarms with emphasis on ventricular tachycardia.
    Rodrigues R; Couto P
    Physiol Meas; 2016 Aug; 37(8):1326-39. PubMed ID: 27454934
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reducing false arrhythmia alarms in the ICU using multimodal signals and robust QRS detection.
    Sadr N; Huvanandana J; Nguyen DT; Kalra C; McEwan A; de Chazal P
    Physiol Meas; 2016 Aug; 37(8):1340-54. PubMed ID: 27455121
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reducing false asystole alarms in intensive care.
    Dekimpe R; Heldt T
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():2292-2295. PubMed ID: 29060355
    [TBL] [Abstract][Full Text] [Related]  

  • 17. False alarm reduction in critical care.
    Clifford GD; Silva I; Moody B; Li Q; Kella D; Chahin A; Kooistra T; Perry D; Mark RG
    Physiol Meas; 2016 Aug; 37(8):E5-E23. PubMed ID: 27454172
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Heartbeat detection in multimodal physiological signals using signal quality assessment based on sample entropy.
    Singh O; Sunkaria RK
    Australas Phys Eng Sci Med; 2017 Dec; 40(4):917-923. PubMed ID: 28887765
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensor fusion methods for reducing false alarms in heart rate monitoring.
    Borges G; Brusamarello V
    J Clin Monit Comput; 2016 Dec; 30(6):859-867. PubMed ID: 26439831
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reducing false arrhythmia alarm rates using robust heart rate estimation and cost-sensitive support vector machines.
    Zhang Q; Chen X; Fang Z; Zhan Q; Yang T; Xia S
    Physiol Meas; 2017 Feb; 38(2):259-271. PubMed ID: 28099159
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.