BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

408 related articles for article (PubMed ID: 26219014)

  • 1. Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal metastases.
    Zhen H; Hrycushko B; Lee H; Timmerman R; Pompoš A; Stojadinovic S; Foster R; Jiang SB; Solberg T; Gu X
    J Appl Clin Med Phys; 2015 Jul; 16(4):181–192. PubMed ID: 26219014
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer.
    Han T; Followill D; Mikell J; Repchak R; Molineu A; Howell R; Salehpour M; Mourtada F
    Med Phys; 2013 May; 40(5):051710. PubMed ID: 23635258
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Benchmarking techniques for stereotactic body radiotherapy for early-stage glottic laryngeal cancer: LINAC-based non-coplanar VMAT vs. Cyberknife planning.
    Zhang Y; Chiu T; Dubas J; Tian Z; Lee P; Gu X; Yan Y; Sher D; Timmerman R; Zhao B
    Radiat Oncol; 2019 Nov; 14(1):193. PubMed ID: 31684993
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric comparison of analytical anisotropic algorithm and the two dose reporting modes of Acuros XB dose calculation algorithm in volumetric modulated arc therapy of carcinoma lung and carcinoma prostate.
    Gopalakrishnan Z; Bhasi S; P R; Menon SV; B S; Thayil AG; Nair RK
    Med Dosim; 2022 Autumn; 47(3):280-287. PubMed ID: 35690544
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans.
    Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V
    Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom.
    Han T; Mourtada F; Kisling K; Mikell J; Followill D; Howell R
    Med Phys; 2012 Apr; 39(4):2193-202. PubMed ID: 22482641
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans.
    Kroon PS; Hol S; Essers M
    Radiat Oncol; 2013 Jun; 8():149. PubMed ID: 23800024
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Difference in target dose distributions between Acuros XB and collapsed cone convolution/superposition and the impact of the tumor locations in clinical cases of stereotactic ablative body radiotherapy for lung cancer.
    Inoue K; Matsukawa H; Kasai Y; Edamitsu K; Matsumoto K; Suetsugu Y; Hirose TA; Fukunaga JI; Shioyama Y; Sasaki T
    J Cancer Res Ther; 2023; 19(5):1261-1266. PubMed ID: 37787293
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric effects of the acuros XB and anisotropic analytical algorithm on volumetric modulated arc therapy planning for prostate cancer using an endorectal balloon.
    Koo T; Chung JB; Eom KY; Seok JY; Kim IA; Kim JS
    Radiat Oncol; 2015 Feb; 10():48. PubMed ID: 25890071
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric comparison of analytic anisotropic algorithm and Acuros XB algorithm in VMAT plans for high-grade glioma.
    Takizawa T; Tanabe S; Utsunomiya S; Nakano H; Yamada T; Sakai H; Ohta A; Saito H; Nakano T; Abe E; Kaidu M; Aoyama H
    Phys Med; 2020 May; 73():73-82. PubMed ID: 32330814
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy.
    Hirata K; Nakamura M; Yoshimura M; Mukumoto N; Nakata M; Ito H; Inokuchi H; Matsuo Y; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2015 Jul; 16(4):52–64. PubMed ID: 26218997
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms.
    Ong CCH; Ang KW; Soh RCX; Tin KM; Yap JHH; Lee JCL; Bragg CM
    Med Dosim; 2017 Autumn; 42(3):216-222. PubMed ID: 28711478
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Difference in dose-volumetric data between the analytical anisotropic algorithm, the dose-to-medium, and the dose-to-water reporting modes of the Acuros XB for lung stereotactic body radiation therapy.
    Mampuya WA; Nakamura M; Hirose Y; Kitsuda K; Ishigaki T; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2016 Sep; 17(5):341-347. PubMed ID: 27685138
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media.
    Han T; Mikell JK; Salehpour M; Mourtada F
    Med Phys; 2011 May; 38(5):2651-64. PubMed ID: 21776802
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for dose calculation in treatment of oesophageal cancer: effects on modelling tumour control probability.
    Padmanaban S; Warren S; Walsh A; Partridge M; Hawkins MA
    Radiat Oncol; 2014 Dec; 9():286. PubMed ID: 25533761
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Verification and dosimetric impact of Acuros XB algorithm on intensity modulated stereotactic radiotherapy for locally persistent nasopharyngeal carcinoma.
    Kan MW; Leung LH; Yu PK
    Med Phys; 2012 Aug; 39(8):4705-14. PubMed ID: 22894395
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of Acuros XB algorithm based on RTOG 0813 dosimetric criteria for SBRT lung treatment with RapidArc.
    Rana S; Rogers K; Pokharel S; Cheng C
    J Appl Clin Med Phys; 2014 Jan; 15(1):4474. PubMed ID: 24423844
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma.
    Kan MW; Leung LH; So RW; Yu PK
    Med Phys; 2013 Mar; 40(3):031714. PubMed ID: 23464309
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.
    Tsuruta Y; Nakata M; Nakamura M; Matsuo Y; Higashimura K; Monzen H; Mizowaki T; Hiraoka M
    Med Phys; 2014 Aug; 41(8):081715. PubMed ID: 25086525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric comparison and validation of Eclipse Anisotropic Analytical Algorithm (AAA) and AcurosXB (AXB) algorithms in RapidArc-based radiosurgery plans of patients with solitary brain metastasis.
    Menon SV; P R; Bhasi S; Gopalakrishnan Z; B S; K S; Nair RK
    Med Dosim; 2022 Spring; 47(1):e7-e12. PubMed ID: 34740518
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.