These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 26224910)

  • 1. The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron.
    Fantidis JG; Nicolaou GE; Potolias C; Vordos N; Bandekas DV
    J Radioanal Nucl Chem; 2011; 290(2):289-295. PubMed ID: 26224910
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A compact neutron beam generator system designed for prompt gamma nuclear activation analysis.
    Ghassoun J; Mostacci D
    Appl Radiat Isot; 2011 Aug; 69(8):1138-42. PubMed ID: 21129990
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design of a DT neutron source based PGNAA facility for element determination in aqueous solution.
    Cai P; Hei D; Chen J; Jia W; Cheng C; Sun A; Zhao D
    Appl Radiat Isot; 2022 Oct; 188():110394. PubMed ID: 35988527
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prompt gamma ray detection and imaging for boron neutron capture therapy using CdTe detector and novel detector shield - Monte Carlo study.
    Moktan H; Lee CL; Cho SH
    Med Phys; 2023 Mar; 50(3):1736-1745. PubMed ID: 36625477
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of thermal neutron distribution of an Am-Be neutron source setup by CdZnTe detector.
    Liang X; Zhao D; Jia W; Hei D; Cheng C
    Appl Radiat Isot; 2023 Jun; 196():110778. PubMed ID: 36996536
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MCNP benchmark of a
    Cheng C; Wei Z; Hei D; Jia W; Li J; Cai P; Gao Y; Shan Q; Ling Y
    Appl Radiat Isot; 2020 Apr; 158():109045. PubMed ID: 31989932
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MCNP simulation and experimental study in situ low-grade copper analysis based on PGNAA.
    Jie C; Reng-Bo W; Yan Z; Wen-Bao J; Chong-Gui Z; Rui C; Jin-Hui Q; Yang-Yang F; Jun H
    Appl Radiat Isot; 2024 Apr; 206():111224. PubMed ID: 38324935
    [TBL] [Abstract][Full Text] [Related]  

  • 8. PGNAA system preliminary design and measurement of In-Hospital Neutron Irradiator for boron concentration measurement.
    Zhang Z; Chong Y; Chen X; Jin C; Yang L; Liu T
    Appl Radiat Isot; 2015 Dec; 106():161-5. PubMed ID: 26242556
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simulation of the cement measurement based on the pulse DT neutron generator: A Monte Carlo study.
    Gao Y; Li J; Li J; Liu L
    PLoS One; 2021; 16(6):e0252078. PubMed ID: 34125857
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prompt gamma ray evaluation for chlorine analysis in blended cement concrete.
    Naqvi AA; Maslehuddin M; Kalakada Z; Al-Amoudi OSB
    Appl Radiat Isot; 2014 Dec; 94():8-13. PubMed ID: 25063940
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In situ experimental measurement of mercury by combining PGNAA and characteristic X-ray fluorescence.
    Zhang Y; Yao Z; Tang B; Liu Z; Gong R; Li B; Cheng Z; Hu B
    Appl Radiat Isot; 2021 Feb; 168():109488. PubMed ID: 33239195
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of 7Li(p,n) reaction as a neutron source in a PGNAA setup.
    Naqvi AA; Nagadi MM
    Appl Radiat Isot; 2005 Mar; 62(3):411-8. PubMed ID: 15607917
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a new deuterium-deuterium (D-D) neutron generator for prompt gamma-ray neutron activation analysis.
    Bergaoui K; Reguigui N; Gary CK; Brown C; Cremer JT; Vainionpaa JH; Piestrup MA
    Appl Radiat Isot; 2014 Dec; 94():319-327. PubMed ID: 25305524
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improving the safety of a body composition analyser based on the PGNAA method.
    Miri-Hakimabad H; Izadi-Najafabadi R; Vejdani-Noghreiyan A; Panjeh H
    J Radiol Prot; 2007 Dec; 27(4):457-64. PubMed ID: 18268376
    [TBL] [Abstract][Full Text] [Related]  

  • 15. NaI detector neutron activation spectra for PGNAA applications.
    Gardner RP; El Sayyed; Zheng Y; Hayden S; Mayo CW
    Appl Radiat Isot; 2000 Oct; 53(4-5):483-97. PubMed ID: 11003483
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance tests of external moderators of a PGNAA setup.
    Naqvi AA; Fazal-ur-Rehman ; Al-Jarallah MI; Abu-Jarad F; Maslehuddin M
    Appl Radiat Isot; 2003 Jan; 58(1):27-38. PubMed ID: 12485660
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Study on the PGNAA measurement of heavy metals in aqueous solution by the Monte Carlo-Library Least-Squares (MCLLS) approach.
    Zhang Y; Jia W; Gardner R; Shan Q; Hei D
    Appl Radiat Isot; 2018 Feb; 132():13-17. PubMed ID: 29128851
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volume fraction detection in multiphase systems using neutron activation analysis and artificial neural network.
    Dam RSF; Salgado WL; Conti CC; Schirru R; Salgado CM
    Appl Radiat Isot; 2024 Dec; 214():111504. PubMed ID: 39276638
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source.
    Paaren KM; Kilby S; Lee HK
    Appl Radiat Isot; 2020 Jun; 160():109107. PubMed ID: 32351216
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo simulation of moderator and reflector in coal analyzer based on a D-T neutron generator.
    Shan Q; Chu S; Jia W
    Appl Radiat Isot; 2015 Nov; 105():204-208. PubMed ID: 26325583
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.