BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 2622649)

  • 1. Human tear film pre-rupture phase time (TP-RPT)--a non-invasive technique for evaluating the pre-corneal tear film using a novel keratometer mire.
    Hirji N; Patel S; Callander M
    Ophthalmic Physiol Opt; 1989 Apr; 9(2):139-42. PubMed ID: 2622649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.
    Llorens-Quintana C; Mousavi M; Szczesna-Iskander D; Iskander DR
    Cont Lens Anterior Eye; 2018 Feb; 41(1):18-22. PubMed ID: 28863982
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pre-contact lens and pre-corneal tear film kinetics.
    Guillon M; Dumbleton K; Theodoratos P; Patel K; Gupta R; Patel T
    Cont Lens Anterior Eye; 2019 Jun; 42(3):246-252. PubMed ID: 30819629
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.
    Wang J; Fonn D; Simpson TL; Jones L
    Invest Ophthalmol Vis Sci; 2003 Jun; 44(6):2524-8. PubMed ID: 12766052
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics.
    Guillon M; Dumbleton KA; Theodoratos P; Wong S; Patel K; Banks G; Patel T
    Optom Vis Sci; 2016 Aug; 93(8):881-91. PubMed ID: 27092926
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of short term contact lens wear on the tear film and ocular surface characteristics of tolerant and intolerant wearers.
    Glasson MJ; Stapleton F; Keay L; Willcox MD
    Cont Lens Anterior Eye; 2006 Mar; 29(1):41-7; quiz 49. PubMed ID: 16497539
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tear film dynamics with blinking and contact lens motion.
    Anderson DM; Corsaro M; Horton J; Reid T; Seshaiyer P
    Math Med Biol; 2021 Aug; 38(3):355-395. PubMed ID: 34286343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Estimating tear film spread and stability through tear hydrodynamics.
    Varikooty J; Keir N; Simpson T
    Optom Vis Sci; 2012 Aug; 89(8):E1119-24. PubMed ID: 22820473
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tear film surface quality with soft contact lenses using dynamic-area high-speed videokeratoscopy.
    Alonso-Caneiro D; Iskander DR; Collins MJ
    Eye Contact Lens; 2009 Sep; 35(5):227-31. PubMed ID: 19657279
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanism of tear film rupture and its implications for contact lens tolerance.
    Sharma A; Ruckenstein E
    Am J Optom Physiol Opt; 1985 Apr; 62(4):246-53. PubMed ID: 3993732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An interferometric method for the dynamic evaluation of the tear film.
    Szczesna DH; Kasprzak HT; Jaronski J; Rydz A; Stenevi U
    Acta Ophthalmol Scand; 2007 Mar; 85(2):202-8. PubMed ID: 17305735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of Tear Film Lipid Layer Thickness and Blinking Pattern on Tear Film Instability After Corneal Refractive Surgery.
    Chen Q; Li M; Yuan Y; Me R; Yu Y; Shi G; Wang X; Ke B
    Cornea; 2017 Jul; 36(7):810-815. PubMed ID: 28410354
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Post-lens tear film thinning in rigid gas permeable lenses.
    Taylor AJ; Wilson SD
    Optom Vis Sci; 1995 Dec; 72(12):849-56. PubMed ID: 8749331
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thinning rate of the precorneal and prelens tear films.
    Nichols JJ; Mitchell GL; King-Smith PE
    Invest Ophthalmol Vis Sci; 2005 Jul; 46(7):2353-61. PubMed ID: 15980222
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of rigid contact lens overall and optic zone diameters on tear pump efficiency.
    Fink BA; Hill RM; Carney LG
    Optom Vis Sci; 1990 Aug; 67(8):641-4. PubMed ID: 2216334
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contact lens interactions with the tear film.
    Mann A; Tighe B
    Exp Eye Res; 2013 Dec; 117():88-98. PubMed ID: 23886658
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rigid contact lens design: effects of overall diameter changes on tear pump efficiency.
    Fink BA; Carney LG; Hill RM
    Optom Vis Sci; 1991 Mar; 68(3):198-203. PubMed ID: 2047082
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Objective Analysis of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.
    Marx S; Eckstein J; Sickenberger W
    Clin Optom (Auckl); 2020; 12():203-211. PubMed ID: 33244285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tear film-contact lens interactions.
    Korb DR
    Adv Exp Med Biol; 1994; 350():403-10. PubMed ID: 8030509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Using corneal oxygen demand to optimize rigid contact lens design.
    Fink BA; Hill RM; Carney LG
    Optom Vis Sci; 1993 Oct; 70(10):781-4. PubMed ID: 8247478
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.