These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
172 related articles for article (PubMed ID: 26229219)
1. Analytical method for total chromium and nickel in urine using an inductively coupled plasma-universal cell technology-mass spectrometer (ICP-UCT-MS) in kinetic energy discrimination (KED) mode. Quarles CD; Jones DR; Jarrett JM; Shakirova G; Pan Y; Caldwell KL; Jones RL J Anal At Spectrom; 2014; 2014(2):297-303. PubMed ID: 26229219 [TBL] [Abstract][Full Text] [Related]
2. Development and validation of a biomonitoring method to measure As, Cr, and Ni in human urine samples by ICP-UCT-MS. Jones DR; Jarrett JM; Stukes D; Baer A; McMichael M; Wallon K; Xiao G; Jones RL Int J Hyg Environ Health; 2021 May; 234():113713. PubMed ID: 33621861 [TBL] [Abstract][Full Text] [Related]
3. Validation of a simple inductively coupled plasma mass spectrometry method for detecting urine and serum iodine and evaluation of iodine status of pregnant women in Beijing. Yu S; Yin Y; Cheng Q; Han J; Cheng X; Guo Y; Sun D; Xie S; Qiu L Scand J Clin Lab Invest; 2018 Oct; 78(6):501-507. PubMed ID: 30261754 [TBL] [Abstract][Full Text] [Related]
4. Method validation for a multi-element panel in serum by inductively coupled plasma mass spectrometry (ICP-MS). Johnson-Davis KL; Farnsworth C; Law C; Parker R Clin Biochem; 2020 Aug; 82():90-98. PubMed ID: 32407718 [TBL] [Abstract][Full Text] [Related]
5. Comparing the precision of selenium isotope ratio measurements using collision cell and sector field inductively coupled plasma mass spectrometry. Elwaer N; Hintelmann H Talanta; 2008 Mar; 75(1):205-14. PubMed ID: 18371869 [TBL] [Abstract][Full Text] [Related]
6. Biomonitoring method for the analysis of chromium and cobalt in human whole blood using inductively coupled plasma - kinetic energy discrimination - mass spectrometry (ICP-KED-MS). Georgi JC; Sommer YL; Ward CD; Cheng PY; Jones RL; Caldwell KL Anal Methods; 2017; 9(23):3464-3476. PubMed ID: 29201158 [TBL] [Abstract][Full Text] [Related]
7. Studies on Isotope Ratio Measurement of Cl by Inductively Coupled Plasma Triple-quad Mass Spectrometry. Ohata M; Zhu Y; Nonose N Anal Sci; 2017; 33(3):375-380. PubMed ID: 28302981 [TBL] [Abstract][Full Text] [Related]
8. Multi-element analysis of urine using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS) - a practical application. Brodzka R; Trzcinka-Ochocka M; Janasik B Int J Occup Med Environ Health; 2013 Apr; 26(2):302-12. PubMed ID: 23771860 [TBL] [Abstract][Full Text] [Related]
9. Rapid determination of thorium in urine by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS). Liu Y; Xiao G; Jones RL J Radioanal Nucl Chem; 2022 Sep; 331(9):3957-3964. PubMed ID: 36744001 [TBL] [Abstract][Full Text] [Related]
10. Highly sensitive measurement of whole blood chromium by inductively coupled plasma mass spectrometry. Cieslak W; Pap K; Bunch DR; Reineks E; Jackson R; Steinle R; Wang S Clin Biochem; 2013 Feb; 46(3):266-70. PubMed ID: 23127384 [TBL] [Abstract][Full Text] [Related]
11. High-Throughput Determination of Ultratrace Actinides in Urine by In-Line Extraction Chromatography Combined with Quadrupole Inductively Coupled Plasma Mass Spectrometry (EC-ICP-MS). Liu Y; Xiao G; Jones RL Anal Chem; 2022 Dec; 94(51):18042-18049. PubMed ID: 36519576 [TBL] [Abstract][Full Text] [Related]
12. Simple and robust ICP-MS method for simultaneous determination of serum Co and Cr in routine clinical practice. Choi HJ; Lim SJ; Park YS; Lee SY Clin Chim Acta; 2015 Jan; 439():91-6. PubMed ID: 25278349 [TBL] [Abstract][Full Text] [Related]
13. [Determination of Total Sulfur Dioxide in Chinese Herbal Medicines via Triple Quadrupole Inductively Coupled Plasma Mass Spectrometry]. Wang XW; Liu JF; Guan H; Wang XY; Shag B; Zhang J; Liu LP; Zhang NN Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Feb; 36(2):527-31. PubMed ID: 27209762 [TBL] [Abstract][Full Text] [Related]
14. Development of analytical procedures for determination of total chromium by quadrupole ICP-MS and high-resolution ICP-MS, and hexavalent chromium by HPLC-ICP-MS, in different materials used in the automotive industry. Séby F; Gagean M; Garraud H; Castetbon A; Donard OF Anal Bioanal Chem; 2003 Oct; 377(4):685-94. PubMed ID: 12904954 [TBL] [Abstract][Full Text] [Related]
15. Comparison of high-resolution and dynamic reaction cell ICP-MS capabilities for forensic analysis of iron in glass. Castro W; Trejos T; Naes B; Almirall JR Anal Bioanal Chem; 2008 Oct; 392(4):663-72. PubMed ID: 18679661 [TBL] [Abstract][Full Text] [Related]
16. Chromium speciation by anion-exchange high-performance liquid chromatography with both inductively coupled plasma atomic emission spectroscopic and inductively coupled plasma mass spectrometric detection. Byrdy FA; Olson LK; Vela NP; Caruso JA J Chromatogr A; 1995 Oct; 712(2):311-20. PubMed ID: 7581851 [TBL] [Abstract][Full Text] [Related]
18. Strategies to overcome interferences in elemental and isotopic geochemical analysis by quadrupole inductively coupled plasma mass spectrometry: A critical evaluation of the recent developments. Balaram V Rapid Commun Mass Spectrom; 2021 May; 35(10):e9065. PubMed ID: 33587758 [TBL] [Abstract][Full Text] [Related]
19. Complementary molecular and elemental detection of speciated thioarsenicals using ESI-MS in combination with a xenon-based collision-cell ICP-MS with application to fortified NIST freeze-dried urine. Ellis JL; Conklin SD; Gallawa CM; Kubachka KM; Young AR; Creed PA; Caruso JA; Creed JT Anal Bioanal Chem; 2008 Apr; 390(7):1731-7. PubMed ID: 18157667 [TBL] [Abstract][Full Text] [Related]
20. Biomonitoring of boron: Development and characterization of a simple, reliable and quality controlled biomonitoring method. Michalke B J Trace Elem Med Biol; 2017 Mar; 40():24-29. PubMed ID: 28159218 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]