149 related articles for article (PubMed ID: 26233701)
1. Accuracy of Proximal Tibial Bone Cut Using Anterior Border of Tibia as Bony Landmark in Total Knee Arthroplasty.
Nishikawa K; Mizu-uchi H; Okazaki K; Matsuda S; Tashiro Y; Iwamoto Y
J Arthroplasty; 2015 Dec; 30(12):2121-4. PubMed ID: 26233701
[TBL] [Abstract][Full Text] [Related]
2. The effect of ankle rotation on cutting of the tibia in total knee arthroplasty.
Mizu-uchi H; Matsuda S; Miura H; Higaki H; Okazaki K; Iwamoto Y
J Bone Joint Surg Am; 2006 Dec; 88(12):2632-6. PubMed ID: 17142413
[TBL] [Abstract][Full Text] [Related]
3. The Adjustment of the Rotational Alignment of the Distal End of the Extramedullary Guide to the Anteroposterior Axis of the Proximal Tibia in Total Knee Arthroplasty.
Mizu-Uchi H; Kido H; Chikama T; Kamo K; Kido S; Nakashima Y
J Knee Surg; 2022 Oct; 35(12):1273-1279. PubMed ID: 33511586
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of a proximal tibial cutting method using the anterior tibial border in TKA.
Sasanuma H; Sekiya H; Takatoku K; Ajiki T; Hagiwara H
Eur J Orthop Surg Traumatol; 2014 Dec; 24(8):1525-30. PubMed ID: 24449002
[TBL] [Abstract][Full Text] [Related]
5. Anterior border of the tibia as a landmark for extramedullary alignment guide in total knee arthroplasty for varus knees.
Fukagawa S; Matsuda S; Mitsuyasu H; Miura H; Okazaki K; Tashiro Y; Iwamoto Y
J Orthop Res; 2011 Jun; 29(6):919-24. PubMed ID: 21259337
[TBL] [Abstract][Full Text] [Related]
6. Bony landmarks with tibial cutting surface are useful to avoid rotational mismatch in total knee arthroplasty.
Ma Y; Mizu-Uchi H; Ushio T; Hamai S; Akasaki Y; Murakami K; Nakashima Y
Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1570-1579. PubMed ID: 29995165
[TBL] [Abstract][Full Text] [Related]
7. Improving tibial component alignment in total knee arthroplasty.
Cinotti G; Sessa P; D'Arino A; Ripani FR; Giannicola G
Knee Surg Sports Traumatol Arthrosc; 2015 Dec; 23(12):3563-70. PubMed ID: 25218573
[TBL] [Abstract][Full Text] [Related]
8. The distance from the extramedullary cutting guide rod to the skin surface as a reference guide for the tibial slope in total knee arthroplasty.
Tsukeoka T; Tsuneizumi Y
Knee; 2016 Mar; 23(2):314-7. PubMed ID: 26791680
[TBL] [Abstract][Full Text] [Related]
9. Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty.
Kim JI; Jang J; Lee KW; Han HS; Lee S; Lee MC
BMC Musculoskelet Disord; 2017 Jun; 18(1):252. PubMed ID: 28606122
[TBL] [Abstract][Full Text] [Related]
10. The "midsulcus line" as a landmark for tibial resection during total knee arthroplasty.
Dalury DF; Aram LJ
Knee; 2016 Jun; 23(3):529-31. PubMed ID: 26919760
[TBL] [Abstract][Full Text] [Related]
11. The anteroposterior axis of the tibia in Korean patients undergoing total knee replacement.
Kim CW; Seo SS; Kim JH; Roh SM; Lee CR
Bone Joint J; 2014 Nov; 96-B(11):1485-90. PubMed ID: 25371461
[TBL] [Abstract][Full Text] [Related]
12. Extensor hallucis longus tendon is a new distal landmark for coronal tibial component alignment in total knee arthroplasty: A study of magnetic resonance imaging.
Hino M; Nakagawa S; Arai Y; Inoue H; Kan H; Fujii Y; Ikoma K; Kubo T
J Orthop Surg (Hong Kong); 2020; 28(1):2309499020912340. PubMed ID: 32223512
[TBL] [Abstract][Full Text] [Related]
13. The effect of rotational fixation error of the tibial cutting guide and the distance between the guide and the bone on the tibial osteotomy in total knee arthroplasty.
Tsukeoka T; Tsuneizumi Y; Lee TH
J Arthroplasty; 2013 Aug; 28(7):1094-8. PubMed ID: 23528550
[TBL] [Abstract][Full Text] [Related]
14. Efficacy Analysis of Selection of Distal Reference Point for Tibial Coronal Plane Osteotomy during Total Knee Arthroplasty: A Literature Review.
Men J; Liang HG; Wang ZW; Sun P; Feng W
Orthop Surg; 2021 Jul; 13(5):1682-1693. PubMed ID: 34142453
[TBL] [Abstract][Full Text] [Related]
15. [Reliability of tibial anterior crest as the anatomical reference of rotating alignment for tibial component in total knee arthroplasty].
Lu YF; Ren XY; Hao YQ; Xu P; Liu BY
Zhongguo Gu Shang; 2021 May; 34(5):417-24. PubMed ID: 34032042
[TBL] [Abstract][Full Text] [Related]
16. Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.
Miyatake N; Sugita T; Aizawa T; Sasaki A; Maeda I; Kamimura M; Fujisawa H; Takahashi A
J Orthop Sci; 2016 Sep; 21(5):635-9. PubMed ID: 27380729
[TBL] [Abstract][Full Text] [Related]
17. Lateralization of Tibial Plateau Reference Point Improves Accuracy of Tibial Resection in Total Knee Arthroplasty in Patients with Proximal Tibia Vara.
Thippana RK; Kumar MN
Clin Orthop Surg; 2017 Dec; 9(4):458-464. PubMed ID: 29201298
[TBL] [Abstract][Full Text] [Related]
18. Anteroposterior Rotational References of the Tibia for Medial Unicompartmental Knee Arthroplasty in Japanese Patients.
Tsukamoto I; Akagi M; Mori S; Inoue S; Asada S; Matsumura F
J Arthroplasty; 2017 Oct; 32(10):3169-3175. PubMed ID: 28559197
[TBL] [Abstract][Full Text] [Related]
19. The distal tibiofibular syndesmosis is a reliable landmark for 3° varus tibial resection in total knee arthroplasty: a radiological evaluation on 1296 cases.
Perelli S; Costa GG; Russo A; Hinarejos P; Torres-Claramunt R; Sanchez-Soler J; Morales-Avalos R; Monllau JC
Arch Orthop Trauma Surg; 2024 Feb; 144(2):879-885. PubMed ID: 37864591
[TBL] [Abstract][Full Text] [Related]
20. Do modern total knee replacements improve tibial coverage?
Meier M; Webb J; Collins JE; Beckmann J; Fitz W
Knee Surg Sports Traumatol Arthrosc; 2018 Nov; 26(11):3219-3229. PubMed ID: 29372284
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]