These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 26233701)

  • 21. The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty (TKA).
    Drexler M; Backstein D; Studler U; Lakstein D; Haviv B; Schwarzkopf R; Rutenberg TF; Warschawski Y; Rath E; Kosashvili Y
    Knee Surg Sports Traumatol Arthrosc; 2017 Jun; 25(6):1736-1742. PubMed ID: 27017213
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty.
    Yang SH; Liu TK
    J Formos Med Assoc; 1998 Aug; 97(8):564-8. PubMed ID: 9747068
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The dorsal pedis artery as a new distal landmark for extramedullary tibial alignment in total knee arthroplasty.
    Sugimura N; Ikeuchi M; Izumi M; Aso K; Ushida T; Tani T
    Knee Surg Sports Traumatol Arthrosc; 2014 Nov; 22(11):2618-22. PubMed ID: 23455389
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Rotational alignment of the tibial component affects the kinematic rotation of a weight-bearing knee after total knee arthroplasty.
    Nakahara H; Okazaki K; Hamai S; Kawahara S; Higaki H; Mizu-uchi H; Iwamoto Y
    Knee; 2015 Jun; 22(3):201-5. PubMed ID: 25800285
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anatomical references for tibial sagittal alignment in total knee arthroplasty: a comparison of three anatomical axes based on 3D reconstructed CT images.
    Shao JJ; Parker Vail T; Wang QJ; Shen H; Chen YS; Wang Q; Jiang Y; Zhang XL
    Chin Med J (Engl); 2013 Oct; 126(20):3840-4. PubMed ID: 24157142
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty.
    Inui H; Taketomi S; Yamagami R; Sanada T; Tanaka S
    Knee; 2016 Jan; 23(1):173-6. PubMed ID: 25982299
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanically aligned total knee arthroplasty carries a risk of bony gap changes and flexion-extension axis displacement.
    Niki Y; Sassa T; Nagai K; Harato K; Kobayashi S; Yamashita T
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3452-3458. PubMed ID: 28224199
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Anatomical landmarks of the distal femoral condyles are not always parallel to the tibial bone cut surface in flexion during total knee arthroplasty.
    Itokazu M; Minoda Y; Ikebuchi M; Mizokawa S; Ohta Y; Nakamura H
    Knee; 2016 Aug; 23(4):725-9. PubMed ID: 27117168
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of tibial torsion on distal alignment of extramedullary instrumentation in total knee arthroplasty.
    Cinotti G; Sessa P; Rocca AD; Ripani FR; Giannicola G
    Acta Orthop; 2013 Jun; 84(3):275-9. PubMed ID: 23594222
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Tibial shaft axis does not always serve as a correct coronal landmark in total knee arthroplasty for varus knees.
    Matsuda S; Mizu-uchi H; Miura H; Nagamine R; Urabe K; Iwamoto Y
    J Arthroplasty; 2003 Jan; 18(1):56-62. PubMed ID: 12555184
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Research on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty].
    Yu HC; Wen H; Zhang Y; Hu YZ; Wu JB; Kong JZ
    Zhongguo Gu Shang; 2015 Oct; 28(10):884-7. PubMed ID: 26727777
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mapping of the anterior tibial profile to identify accurate reference points for sagittal alignment of tibial component in total knee arthroplasty.
    Cinotti G; Caruso E; Orsina L; La Torre G; Ripani FR
    Orthop Traumatol Surg Res; 2017 Oct; 103(6):959-963. PubMed ID: 28645703
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Radiographic analysis of a hand-held surgical navigation system for tibial resection in total knee arthroplasty.
    Nam D; Jerabek SA; Haughom B; Cross MB; Reinhardt KR; Mayman DJ
    J Arthroplasty; 2011 Dec; 26(8):1527-33. PubMed ID: 21397455
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The landmarks of centers of the distal femur and the proximal tibia in sagittal plane for application in computer assisted total knee arthroplasty.
    Hangsaphuk N; Tanavalee A
    J Med Assoc Thai; 2009 Dec; 92 Suppl 6():S69-74. PubMed ID: 20128072
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The tibial lateral axis is a novel extraarticular landmark for detection of the tibial anteroposterior axis.
    Hiranaka T; Tanaka T; Fujishiro T; Anjiki K; Nagata N; Kitazawa D; Kotoura K; Okamoto K
    Surg Radiol Anat; 2020 Oct; 42(10):1195-1202. PubMed ID: 32514589
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Rotational positioning of the tibial tray in total knee arthroplasty: a CT evaluation.
    Berhouet J; Beaufils P; Boisrenoult P; Frasca D; Pujol N
    Orthop Traumatol Surg Res; 2011 Nov; 97(7):699-704. PubMed ID: 21993150
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial.
    Blakeney WG; Khan RJ; Wall SJ
    J Bone Joint Surg Am; 2011 Aug; 93(15):1377-84. PubMed ID: 21915542
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Location of the ankle center for total knee arthroplasty.
    Asada S; Mori S; Inoue S; Tsukamoto I; Akagi M
    Knee; 2017 Jan; 24(1):121-127. PubMed ID: 27825939
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Technical Considerations and Accuracy Improvement of Accelerometer-Based Portable Computer Navigation for Performing Distal Femoral Resection in Total Knee Arthroplasty.
    Fujimoto E; Sasashige Y; Nakata K; Yokota G; Omoto T; Ochi M
    J Arthroplasty; 2017 Jan; 32(1):53-60. PubMed ID: 27365295
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of the rotational alignment of the tibial component in total knee arthroplasty: position prioritizing maximum coverage.
    Hirakawa M; Miyazaki M; Ikeda S; Matsumoto Y; Kondo M; Tsumura H
    Eur J Orthop Surg Traumatol; 2017 Jan; 27(1):119-124. PubMed ID: 27614951
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.