These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 26240626)

  • 1. Endoscopic metal enteral stent placement for malignant afferent loop syndrome after pancreaticoduodenectomy.
    Huang J; Hao S; Yang F; Di Y; Yao L; Li J; Jiang Y; Zhong L; Fu D; Jin C
    Wideochir Inne Tech Maloinwazyjne; 2015 Jul; 10(2):257-65. PubMed ID: 26240626
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Early and late effects of endoscopic interventions in patients with malignant afferent loop syndrome: A single-center experience and literature review.
    Yamamoto K; Itoi T; Matsunami Y; Sofuni A; Tsuchiya T; Mukai S; Kojima H; Minami H; Nakatsubo R; Tonozuka R
    J Hepatobiliary Pancreat Sci; 2024 Feb; 31(2):120-132. PubMed ID: 37907717
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endoscopic Self-Expandable Metal Stent Placement for Malignant Afferent Loop Obstruction After Pancreaticoduodenectomy: A Case Series and Review.
    Sakai A; Shiomi H; Iemoto T; Nakano R; Ikegawa T; Kobayashi T; Masuda A; Kodama Y
    Clin Endosc; 2020 Jul; 53(4):491-496. PubMed ID: 32124582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous Enteral Stent Placement Using a Transhepatic Access for Palliation of Malignant Bowel Obstruction after Surgery.
    Choi WS; Yoon CJ; Lee JH
    Korean J Radiol; 2021 May; 22(5):742-750. PubMed ID: 33569933
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous transhepatic metallic stent insertion for malignant afferent loop obstruction following pancreaticoduodenectomy: a case report.
    Hosokawa I; Kato A; Shimizu H; Furukawa K; Miyazaki M
    J Med Case Rep; 2012 Jul; 6():198. PubMed ID: 22800503
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endoscopic Ultrasound-Guided Gastroenterostomy for Afferent Loop Syndrome.
    Shiomi H; Sakai A; Nakano R; Ota S; Kobayashi T; Masuda A; Iijima H
    Clin Endosc; 2021 Nov; 54(6):810-817. PubMed ID: 34775697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endoscopic management of afferent loop syndrome after a pylorus preserving pancreatoduodenecotomy presenting with obstructive jaundice and ascending cholangitis.
    Kim JK; Park CH; Huh JH; Park JY; Park SW; Song SY; Chung J; Bang S
    Clin Endosc; 2011 Sep; 44(1):59-64. PubMed ID: 22741115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Enteral stenting for gastric outlet obstruction and afferent limb syndrome following pancreaticoduodenectomy.
    Kwong WT; Fehmi SM; Lowy AM; Savides TJ
    Ann Gastroenterol; 2014; 27(4):413-417. PubMed ID: 25332208
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Afferent-Loop Syndrome Treated with Endoscopic Ultrasound-Guided Drainage of the Afferent Loop with a Plastic Stent.
    Tanikawa T; Urata N; Ishii K; Katsumata R; Nishino K; Suehiro M; Kawanaka M; Haruma K; Kawamoto H
    Case Rep Gastroenterol; 2022; 16(1):122-128. PubMed ID: 35528775
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscopic ultrasound-guided drainage using lumen-apposing metal stent of malignant afferent limb syndrome in patients with previous Whipple surgery: Multicenter study (with video).
    Pérez-Cuadrado-Robles E; Bronswijk M; Prat F; Barthet M; Palazzo M; Arcidiacono P; Schaefer M; Devière J; van Wanrooij RLJ; Tarantino I; Donatelli G; Camus M; Sanchez-Yague A; Pham KD; Gonzalez JM; Anderloni A; Vila JJ; Jezequel J; Larghi A; Jaïs B; Vazquez-Sequeiros E; Deprez PH; Van der Merwe S; Cellier C; Rahmi G
    Dig Endosc; 2022 Nov; 34(7):1433-1439. PubMed ID: 35429360
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enteral stent placement for malignant afferent loop obstruction by the through-the-scope technique using a short-type single-balloon enteroscope.
    Sasaki T; Yamada I; Matsuyama M; Sasahira N
    Endosc Int Open; 2018 Jul; 6(7):E806-E811. PubMed ID: 29977998
    [No Abstract]   [Full Text] [Related]  

  • 12. Effectiveness of endoscopic self-expandable metal stent placement for afferent loop obstruction caused by pancreatic cancer recurrence after pancreaticoduodenectomy.
    Sakai A; Shiomi H; Okabe Y; Yagi Y; Kobayashi T; Shiomi Y; Takenaka M; Hoshi N; Arisaka Y; Kutsumi H; Azuma T
    Clin J Gastroenterol; 2015 Apr; 8(2):103-7. PubMed ID: 25708451
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Palliation of malignant gastric outlet obstruction with simultaneous endoscopic insertion of afferent and efferent jejunal limb enteral stents in patients with recurrent malignancy.
    Soo I; Gerdes H; Markowitz AJ; Mendelsohn RB; Ludwig E; Shah P; Schattner MA
    Surg Endosc; 2016 Feb; 30(2):521-525. PubMed ID: 26091983
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enteral self-expandable metal stent placement for malignant afferent limb syndrome using single-balloon enteroscope: report of five cases.
    Yane K; Katanuma A; Hayashi T; Takahashi K; Kin T; Nagai K; Tanaka K; Komatsu N; Endo M; Kobayashi Y; Takigawa Y; Utsunomiya R
    Endosc Int Open; 2018 Nov; 6(11):E1330-E1335. PubMed ID: 30410953
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endoscopic Transluminal Stent Placement for Malignant Afferent Loop Obstruction.
    Yonekura C; Sasaki T; Mie T; Okamoto T; Takeda T; Furukawa T; Yamada Y; Kasuga A; Matsuyama M; Ozaka M; Sasahira N
    J Clin Med; 2022 Oct; 11(21):. PubMed ID: 36362585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Self-expanding metal stent procedure for afferent loop syndrome with ascending cholangitis caused by remnant gastric cancer: A case report.
    Cha RR; Cho SB; Kim WS; Kim JJ; Lee JM; Lee SS; Kim HJ; Cho JK
    Medicine (Baltimore); 2018 Dec; 97(50):e13072. PubMed ID: 30557964
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Usefulness of endoscopic metal stent placement for malignant afferent loop obstruction.
    Kida A; Kido H; Matsuo T; Mizukami A; Yano M; Arihara F; Matsuda K; Ogawa K; Matsuda M; Sakai A
    Surg Endosc; 2020 May; 34(5):2103-2112. PubMed ID: 31338663
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endoscopic self-expandable metal stent placement for malignant afferent loop obstruction caused by peritoneal recurrence after total gastrectomy.
    Takeuchi H; Abe N; Kondou E; Tsurumi M; Hashimoto Y; Ooki A; Nagao G; Masaki T; Mori T; Sugiyama M
    Int Cancer Conf J; 2018 Jul; 7(3):98-102. PubMed ID: 31149524
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Metallic stent insertion with double-balloon endoscopy for malignant afferent loop obstruction.
    Fujii M; Ishiyama S; Saito H; Ito M; Fujiwara A; Niguma T; Yoshioka M; Shiode J
    World J Gastrointest Endosc; 2015 Jun; 7(6):665-9. PubMed ID: 26078835
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Expanding endoscopic treatment strategies for pancreatic leaks following pancreato-duodenectomy: a single centre experience.
    Mutignani M; Bonato G; Dioscoridi L; Mazzola M; Cintolo M; Pugliese F; Rosa R; Italia A; Ferrari G; Forti E
    Surg Endosc; 2021 Apr; 35(4):1908-1914. PubMed ID: 33403464
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.