BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

285 related articles for article (PubMed ID: 26245456)

  • 1. Pyridoxal Based Fluorescent Chemosensor for Detection of Copper(II) in Solution With Moderate Selectivity and Live Cell Imaging.
    Mandal S; Mandal SK; Khuda-Bukhsh AR; Goswami S
    J Fluoresc; 2015 Sep; 25(5):1437-47. PubMed ID: 26245456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A pyrene-based highly selective turn-on fluorescent sensor for copper(II) ion and its application in live cell imaging.
    Wu SP; Huang ZM; Liu SR; Chung PK
    J Fluoresc; 2012 Jan; 22(1):253-9. PubMed ID: 21870075
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bis-benzimidazolyl diamide based fluorescent probe for copper(II): synthesis, structural and fluorescence studies.
    Mahiya K; Mathur P
    J Fluoresc; 2013 Jul; 23(4):767-76. PubMed ID: 23494165
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of an oxidative dehydrogenation-based fluorescent probe for Cu2+ and its biological imaging in living cells.
    Fan J; Liu X; Hu M; Zhu H; Song F; Peng X
    Anal Chim Acta; 2012 Jul; 735():107-13. PubMed ID: 22713923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Highly selective fluorescence turn-on chemosensor based on naphthalimide derivatives for detection of copper(II) ions.
    Chen Z; Wang L; Zou G; Tang J; Cai X; Teng M; Chen L
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 Mar; 105():57-61. PubMed ID: 23291230
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new Schiff base fluorescent probe for imaging Cu2+ in living cells.
    Ye H; Ge F; Zhou YM; Liu JT; Zhao BX
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 Aug; 112():132-8. PubMed ID: 23666347
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A fluorescein-based chemosensor for relay fluorescence recognition of Cu(ii) ions and biothiols in water and its applications to a molecular logic gate and living cell imaging.
    Fu ZH; Yan LB; Zhang X; Zhu FF; Han XL; Fang J; Wang YW; Peng Y
    Org Biomol Chem; 2017 May; 15(19):4115-4121. PubMed ID: 28379264
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Copper(II) and iron(II) ion sensing with semiconducting polymer dots.
    Chan YH; Jin Y; Wu C; Chiu DT
    Chem Commun (Camb); 2011 Mar; 47(10):2820-2. PubMed ID: 21240410
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metal ion-assisted ring-opening of a quinazoline-based chemosensor: detection of copper(II) in aqueous media.
    Cao W; Zheng XJ; Fang DC; Jin LP
    Dalton Trans; 2015 Mar; 44(11):5191-6. PubMed ID: 25686207
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-in-one type fluorescent sensor based on a pyrene pyridoxal cascade for the selective detection of Zn(ii), hydrogen phosphate and cysteine.
    Upadhyay Y; Anand T; Babu LT; Paira P; Crisponi G; Sk AK; Kumar R; Sahoo SK
    Dalton Trans; 2018 Jan; 47(3):742-749. PubMed ID: 29242864
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 1,8-naphthalimide modified [12]aneN₃ compounds as selective and sensitive probes for Cu²⁺ ions and ATP in aqueous solution and living cells.
    Gao YG; Tang Q; Shi YD; Zhang Y; Lu ZL
    Talanta; 2016 May; 152():438-46. PubMed ID: 26992540
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Label-free, Water-soluble Fluorescent Peptide Probe for a Sensitive and Selective Determination of Copper Ions.
    Yang T; Zhu F; Zhou T; Cao J; Xie Y; Zhang M; Wang Y; Cao DS; Lin Q; Zhang L
    Anal Sci; 2017; 33(2):191-196. PubMed ID: 28190839
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of copper (II) in foodstuffs based on its quenching effect on the fluorescence of N,N'-bis(pyridoxal phosphate)-o-phenylenediamine.
    Xu C; Liao L; He Y; Wu R; Li S; Yang Y
    Spectrochim Acta A Mol Biomol Spectrosc; 2015; 149():662-6. PubMed ID: 25985131
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A retrievable, water-soluble and biocompatible fluorescent probe for recognition of Cu(II) and sulfide based on a peptide receptor.
    Hao Y; Chen W; Wang L; Zhu X; Zhang Y; Qu P; Liu L; Zhou B; Liu YN; Xu M
    Talanta; 2015 Oct; 143():307-314. PubMed ID: 26078164
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A highly selective fluorescent 'turn-on' chemosensor for Zn(2+) based on a benzothiazole conjugate: their applicability in live cell imaging and use of the resultant complex as a secondary sensor of CN(-).
    Khairnar N; Tayade K; Sahoo SK; Bondhopadhyay B; Basu A; Singh J; Singh N; Gite V; Kuwar A
    Dalton Trans; 2015 Feb; 44(5):2097-102. PubMed ID: 25482915
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A highly selective and sensitive fluorescence "turn-on" probe for Ag+ in aqueous solution and live cells.
    Xu L; Xu Y; Zhu W; Yang C; Han L; Qian X
    Dalton Trans; 2012 Jun; 41(24):7212-7. PubMed ID: 22572837
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new fluorescent and colorimetric probe for Cu2+ in live cells.
    Liu WY; Li HY; Zhao BX; Miao JY
    Analyst; 2012 Aug; 137(15):3466-9. PubMed ID: 22701875
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro sensing of Cu(+) through a green fluorescence rise of pyranine.
    Saha T; Sengupta A; Hazra P; Talukdar P
    Photochem Photobiol Sci; 2014 Oct; 13(10):1427-33. PubMed ID: 25057967
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rhodamine-based Cu2+-selective fluorosensor: synthesis, mechanism, and application in living cells.
    Sikdar A; Roy S; Haldar K; Sarkar S; Panja SS
    J Fluoresc; 2013 May; 23(3):495-501. PubMed ID: 23397488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. H(+)-Assisted fluorescent differentiation of Cu(+) and Cu(2+): effect of Al(3+)-induced acidity on chemical sensing and generation of two novel and independent logic gating pathways.
    Ha Y; Murale DP; Yun C; Manjare ST; Kim H; Kwak J; Lee YS; Churchill DG
    Chem Commun (Camb); 2015 Apr; 51(29):6357-60. PubMed ID: 25763413
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.