  • 1. The Effect of a Combination of Implant Controller and Handpiece from Different Manufacturers on the Torque Value.
    Lee DH; Kim YG; Lee JH; Hong SP; Lim YJ; Lee KB
    Int J Oral Maxillofac Implants; 2015; 30(4):761-6. PubMed ID: 26252027
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The overuse of the implant motor: effect on the output torque in overloading condition.
    Lee DH; Cho SA; Lee CH; Lee KB
    Clin Implant Dent Relat Res; 2015 Jun; 17(3):435-41. PubMed ID: 24393515
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of torque measurements and clinical handling of various surgical motors.
    Neugebauer J; Scheer M; Mischkowski RA; An SH; Karapetian VE; Toutenburg H; Zoeller JE
    Int J Oral Maxillofac Implants; 2009; 24(3):469-76. PubMed ID: 19587869
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of repeated use of an implant handpiece on an output torque: An
    Son K; Son YT; Kim JY; Lee JM; Yu WJ; Kim JW; Lee KB
    J Adv Prosthodont; 2021 Jun; 13(3):136-143. PubMed ID: 34234923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of different electronic torque drivers: A comparative evaluation.
    Ko BD; Son K; Kang SH; Lee KB
    J Adv Prosthodont; 2019 Dec; 11(6):350-357. PubMed ID: 31897274
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
    Xia D; Lin H; Yuan S; Bai W; Zheng G
    Biomed Mater Eng; 2014; 24(6):2143-9. PubMed ID: 25226912
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants.
    Goheen KL; Vermilyea SG; Vossoughi J; Agar JR
    Int J Oral Maxillofac Implants; 1994; 9(2):149-55. PubMed ID: 8206549
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of the implant torque wrench following time in clinical service.
    Gutierrez J; Nicholls JI; Libman WJ; Butson TJ
    Int J Prosthodont; 1997; 10(6):562-7. PubMed ID: 9495178
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of a manual torque application device for morse-taper implants: a technical note.
    Cehreli MC; Akça K; Tönük E
    Int J Oral Maxillofac Implants; 2004; 19(5):743-8. PubMed ID: 15508992
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of mechanical torque devices for implants used in Brazilian dental offices.
    Santos GC; Passos SP; Coelho Santos MJ
    Int J Prosthodont; 2011; 24(1):38-9. PubMed ID: 21210000
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of clinicians' ability to hand torque dental implant components.
    Kanawati A; Richards MW; Becker JJ; Monaco NE
    J Oral Implantol; 2009; 35(4):185-8. PubMed ID: 19813423
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative analysis of deformation of two implant/abutment connection systems during implant insertion. An in vitro study.
    Bambini F; Memè L; Pellecchia M; Sabatucci A; Selvaggio R
    Minerva Stomatol; 2005 Mar; 54(3):129-38. PubMed ID: 15920445
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.
    Pauls A; Nienkemper M; Drescher D
    J Orofac Orthop; 2013 Mar; 74(2):124-36. PubMed ID: 23467731
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Variability of mechanical torque-limiting devices in clinical service at a US dental school.
    McCracken MS; Mitchell L; Hegde R; Mavalli MD
    J Prosthodont; 2010 Jan; 19(1):20-4. PubMed ID: 19765196
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Critical bending moment of four implant-abutment interface designs.
    Lee FK; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2010; 25(4):744-51. PubMed ID: 20657869
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An In Vitro Evaluation of the Loosening of Different Interchangeable Abutments in Internal-Connection-Type Implants.
    Park JM; Baek CH; Heo SJ; Kim SK; Koak JY; Kim SK; Belser UC
    Int J Oral Maxillofac Implants; 2017; 32(2):350-355. PubMed ID: 28291853
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.
    Dailey B; Jordan L; Blind O; Tavernier B
    Int J Oral Maxillofac Implants; 2009; 24(2):251-6. PubMed ID: 19492640
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm).
    Khayat PG; Arnal HM; Tourbah BI; Sennerby L
    Clin Implant Dent Relat Res; 2013 Apr; 15(2):227-33. PubMed ID: 21599832
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study.
    Norton MR
    Int J Oral Maxillofac Implants; 2017; 32(4):849-857. PubMed ID: 28708918
    [TBL] [Abstract][Full Text] [Related]  