BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 2625557)

  • 1. [Operative results of tricuspid valve replacement with St. Jude Medical prosthesis].
    Aoyagi S; Tanaka K; Nishi Y; Hara H; Kosuga K; Oishi K
    Nihon Kyobu Geka Gakkai Zasshi; 1989 Dec; 37(12):2463-7. PubMed ID: 2625557
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
    Horstkotte D; Körfer R; Budde T; Haerten K; Schulte HD; Bircks W; Loogen F
    Z Kardiol; 1983 May; 72(5):251-61. PubMed ID: 6880335
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical evaluation of the Björk-Shiley tilting disc valve in the tricuspid position. Early and late results in 10 isolated and 51 combined cases.
    Péterffy A; Henze A; Jonasson R; Björk VO
    Scand J Thorac Cardiovasc Surg; 1978; 12(3):179-87. PubMed ID: 725559
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term survival after tricuspid valve replacement. Results with seven different prostheses.
    Jugdutt BI; Fraser RS; Lee SJ; Rossall RE; Callaghan JC
    J Thorac Cardiovasc Surg; 1977 Jul; 74(1):20-7. PubMed ID: 141548
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Double valve replacement with mechanical prostheses--an operative results].
    Saigenji H; Toyohira H; Shimokawa S; Moriyama Y; Yamaoka A; Taira A
    Nihon Kyobu Geka Gakkai Zasshi; 1995 Sep; 43(9):1600-4. PubMed ID: 8530844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Long-term results in patients with tricuspid prosthesis].
    Martí V; Borrás X; Carreras F; Pons Lladó G; Padró JM; Arís A; Caralps JM
    Rev Esp Cardiol; 1990 Feb; 43(2):67-71. PubMed ID: 2326535
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
    Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E
    G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Tricuspid replacement and short-term follow-up: summary of 42 cases].
    Dong C; Sun LZ; Xu JP; Wu X; Hu SS
    Zhonghua Wai Ke Za Zhi; 2005 Nov; 43(22):1433-6. PubMed ID: 16318807
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tricuspid valve replacement: bioprostheses are preferable.
    Dalrymple-Hay MJ; Leung Y; Ohri SK; Haw MP; Ross JK; Livesey SA; Monro JL
    J Heart Valve Dis; 1999 Nov; 8(6):644-8. PubMed ID: 10616242
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Tricuspid valve replacement by Hancock's prosthesis].
    Delahaye JP; Rondepierre D; Gaspard P; Mikaeloff P; Chassignolle JF; Bourdillon MC; Milon H
    Arch Mal Coeur Vaiss; 1981 Mar; 74(3):281-8. PubMed ID: 6782988
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Mitral valve replacement with the Björk-Shiley monostrut prosthesis: a 4-year clinical experience].
    Alajmo F; Perna AM; Calamai G; Nigro R; Cassai M; Montesi G; Braconi L; Borgioli A; Preziuso M; Palminiello A
    G Ital Cardiol; 1990 Jan; 20(1):44-9. PubMed ID: 2328857
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is a bioprosthesis preferable in tricuspid valve replacement?
    Hayashi J; Saito A; Yamamoto K; Watanabe H; Ohzeki H; Eguchi S
    Thorac Cardiovasc Surg; 1996 Oct; 44(5):230-3. PubMed ID: 8948549
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical and hemodynamic results of cardiac valve replacement with the Monostrut Björk-Shiley prosthesis.
    Aris A; Padró JM; Cámara ML; Crexells C; Augé JM; Caralps JM
    J Thorac Cardiovasc Surg; 1988 Mar; 95(3):423-31. PubMed ID: 3343851
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The St. Jude Medical bileaflet valve prosthesis. A 5 year experience.
    Chaux A; Czer LS; Matloff JM; DeRobertis MA; Stewart ME; Bateman TM; Kass RM; Lee ME; Gray RJ
    J Thorac Cardiovasc Surg; 1984 Nov; 88(5 Pt 1):706-17. PubMed ID: 6492839
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Early and late term results of triple valve replacements. Use of a tricuspid bioprosthesis].
    Mikaeloff P; Delahaye JP; Convert G; Van Haecke P; Amouroux C; Boivin J
    Arch Mal Coeur Vaiss; 1981 Jun; 74(6):719-25. PubMed ID: 6457576
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term follow up of patients undergoing reoperative surgery with aortic or mitral valve replacement using a St. Jude Medical prosthesis.
    Emery RW; Krogh CC; McAdams S; Emery AM; Holter AR
    J Heart Valve Dis; 2010 Jul; 19(4):473-84. PubMed ID: 20845896
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Unexpected findings concerning thromboembolic complications and anticoagulation after complete 10 year follow up of patients with St. Jude Medical prostheses.
    Horstkotte D; Schulte H; Bircks W; Strauer B
    J Heart Valve Dis; 1993 May; 2(3):291-301. PubMed ID: 8269122
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Six-and-half years' experience with the St. Jude BioImplant porcine prosthesis.
    Triggiani M; D'Ancona G; Nascimbene S; Benussi S; Donatelli F; Paolini G; Galli L; Grossi A
    J Heart Valve Dis; 1997 Mar; 6(2):138-44. PubMed ID: 9130121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Long-term results of prosthetic mitral valve replacement with home-made tilting disc valve: a report of 125 cases].
    Zhang BR; Xu ZY; Zou LJ; Mei J; Wang ZN; Hao JH
    Zhonghua Wai Ke Za Zhi; 2003 Apr; 41(4):253-6. PubMed ID: 12882665
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of porcine valve xenografts with mechanical prostheses. A 7 1/2 year experience.
    Joyce LD; Nelson RM
    J Thorac Cardiovasc Surg; 1984 Jul; 88(1):102-13. PubMed ID: 6738092
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.