BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 26265065)

  • 21. Multi-modality 3D mandibular resection planning in head and neck cancer using CT and MRI data fusion: A clinical series.
    Kraeima J; Dorgelo B; Gulbitti HA; Steenbakkers RJHM; Schepman KP; Roodenburg JLN; Spijkervet FKL; Schepers RH; Witjes MJH
    Oral Oncol; 2018 Jun; 81():22-28. PubMed ID: 29884410
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible.
    Bettschart C; Kruse A; Matthews F; Zemann W; Obwegeser JA; Grätz KW; Lübbers HT
    J Craniomaxillofac Surg; 2012 Oct; 40(7):592-8. PubMed ID: 22079336
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Navigation-guided resection of maxillary tumors: Can a new volumetric virtual planning method improve outcomes in terms of control of resection margins?
    Ricotta F; Cercenelli L; Battaglia S; Bortolani B; Savastio G; Marcelli E; Marchetti C; Tarsitano A
    J Craniomaxillofac Surg; 2018 Dec; 46(12):2240-2247. PubMed ID: 30482714
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Image-guided radiotherapy using surgical clips as fiducial markers after prostatectomy: a report of total setup error, required PTV expansion, and dosimetric implications.
    Song S; Yenice KM; Kopec M; Liauw SL
    Radiother Oncol; 2012 May; 103(2):270-4. PubMed ID: 21890224
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips.
    Goldberg H; Prosnitz RG; Olson JA; Marks LB
    Int J Radiat Oncol Biol Phys; 2005 Sep; 63(1):209-13. PubMed ID: 16111591
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Percutaneous radiofrequency ablation of virtual tumours in canine kidney using Global Positioning System-like technology.
    Hung AJ; Ma Y; Zehnder P; Nakamoto M; Gill IS; Ukimura O
    BJU Int; 2012 May; 109(9):1398-403. PubMed ID: 21992738
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Three-dimensional Navigation for Thoracoscopic Sublobar Resection Using a Novel Wireless Marking System.
    Yutaka Y; Sato T; Matsushita K; Aiba H; Muranishi Y; Sakaguchi Y; Sugiura T; Okada M; Nakamura T; Date H
    Semin Thorac Cardiovasc Surg; 2018; 30(2):230-237. PubMed ID: 29530629
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Radiotherapy confined to the tumor bed following breast conserving surgery current status, controversies, and future projects.
    Polgár C; Fodor J; Major T; Takácsi-Nagy Z; Kásler M; Hammer J; Van Limbergen E; Németh G
    Strahlenther Onkol; 2002 Nov; 178(11):597-606. PubMed ID: 12426670
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Intraoperative loss of core biopsy clips: clinical implications.
    Calhoun K; Giuliano A; Brenner RJ
    AJR Am J Roentgenol; 2008 Mar; 190(3):W196-200. PubMed ID: 18287412
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effectiveness and safety of tumor site marking with near-infrared fluorescent clips in colorectal laparoscopic surgery: A case series study.
    Narihiro S; Yoshida M; Ohdaira H; Sato T; Suto D; Hoshimoto S; Suzuki N; Marukuchi R; Kamada T; Takeuchi H; Suzuki Y
    Int J Surg; 2020 Aug; 80():74-78. PubMed ID: 32603784
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Computerized navigation for surgery of the lower jaw: comparison of 2 navigation systems.
    Casap N; Wexler A; Eliashar R
    J Oral Maxillofac Surg; 2008 Jul; 66(7):1467-75. PubMed ID: 18571032
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Development and clinical application of MR simulation system for radiotherapy planning: with reference to intracranial and head and neck regions].
    Okamoto Y; Kodama A; Kono M
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Mar; 57(4):203-10. PubMed ID: 9125877
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Can computer navigation-assisted surgery reduce the risk of an intralesional margin and reduce the rate of local recurrence in patients with a tumour of the pelvis or sacrum?
    Jeys L; Matharu GS; Nandra RS; Grimer RJ
    Bone Joint J; 2013 Oct; 95-B(10):1417-24. PubMed ID: 24078543
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An integrated orthognathic surgery system for virtual planning and image-guided transfer without intermediate splint.
    Kim DS; Woo SY; Yang HJ; Huh KH; Lee SS; Heo MS; Choi SC; Hwang SJ; Yi WJ
    J Craniomaxillofac Surg; 2014 Dec; 42(8):2010-7. PubMed ID: 25458350
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Surgical Clips in Breast-conserving Surgery: Do they Represent the Tumour Bed Accurately?
    Demircioglu O; Aribal E; Uluer M; Ozgen Z; Demircioglu F
    Curr Med Imaging Rev; 2019; 15(6):573-577. PubMed ID: 32008565
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.
    Polley JW; Figueroa AA
    J Oral Maxillofac Surg; 2013 May; 71(5):911-20. PubMed ID: 23312847
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Use of PET/CT examination in head and neck cancer radiotherapy planning].
    Kolárová I; Vanásek J; Odrázka K; Petruzelka L; Dolezel M; Nechvíl J
    Klin Onkol; 2009; 22(3):98-103. PubMed ID: 19708543
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Virtual surgical planning for orthognathic surgery using digital data transfer and an intraoral fiducial marker: the charlotte method.
    Bobek S; Farrell B; Choi C; Farrell B; Weimer K; Tucker M
    J Oral Maxillofac Surg; 2015 Jun; 73(6):1143-58. PubMed ID: 25795181
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Radio-guided seed localization for breast cancer excision: an ex-vivo specimen-based study to establish the accuracy of a freehand-SPECT device in predicting resection margins.
    Pouw B; de Wit-van der Veen LJ; van der Hage JA; Vrancken Peeters MJ; Wesseling J; Stokkel MP; Valdés Olmos RA
    Nucl Med Commun; 2014 Sep; 35(9):961-6. PubMed ID: 24977476
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Image-guided radiotherapy for breast cancer patients: surgical clips as surrogate for breast excision cavity.
    Topolnjak R; de Ruiter P; Remeijer P; van Vliet-Vroegindeweij C; Rasch C; Sonke JJ
    Int J Radiat Oncol Biol Phys; 2011 Nov; 81(3):e187-95. PubMed ID: 21345615
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.