1. Comparison of a simple obstructive sleep apnea screening device with standard in-laboratory polysomnography. Assefa SZ; Diaz-Abad M; Korotinsky A; Tom SE; Scharf SM Sleep Breath; 2016 May; 20(2):537-41. PubMed ID: 26265559 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of a 2-channel portable device and a predictive model to screen for obstructive sleep apnea in a laboratory environment. Zou J; Meng L; Liu Y; Xu X; Liu S; Guan J; Yin S; Yi H Respir Care; 2015 Mar; 60(3):356-62. PubMed ID: 25406349 [TBL] [Abstract][Full Text] [Related]
3. Comparison of diagnostic reliability of out-of-center sleep tests for obstructive sleep apnea between adults and children. Suzuki M; Furukawa T; Sugimoto A; Kotani R; Hosogaya R Int J Pediatr Otorhinolaryngol; 2017 Mar; 94():54-58. PubMed ID: 28167012 [TBL] [Abstract][Full Text] [Related]
4. Combination of symptoms and oxygen desaturation index in predicting childhood obstructive sleep apnea. Chang L; Wu J; Cao L Int J Pediatr Otorhinolaryngol; 2013 Mar; 77(3):365-71. PubMed ID: 23246417 [TBL] [Abstract][Full Text] [Related]
6. The utility of perioperative polygraphy in the diagnosis of obstructive sleep apnea. Cundrle I; Belehrad M; Jelinek M; Olson LJ; Ludka O; Sramek V Sleep Med; 2016 Sep; 25():151-155. PubMed ID: 27823709 [TBL] [Abstract][Full Text] [Related]
7. Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Zou D; Grote L; Peker Y; Lindblad U; Hedner J Sleep; 2006 Mar; 29(3):367-74. PubMed ID: 16553023 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of a single-channel nasal pressure device to assess obstructive sleep apnea risk in laboratory and home environments. Crowley KE; Rajaratnam SM; Shea SA; Epstein LJ; Czeisler CA; Lockley SW; J Clin Sleep Med; 2013 Feb; 9(2):109-16. PubMed ID: 23372462 [TBL] [Abstract][Full Text] [Related]
9. Pediatric pulse oximetry-based OSA screening at different thresholds of the apnea-hypopnea index with an expression of uncertainty for inconclusive classifications. Garde A; Hoppenbrouwer X; Dehkordi P; Zhou G; Rollinson AU; Wensley D; Dumont GA; Ansermino JM Sleep Med; 2019 Aug; 60():45-52. PubMed ID: 31288931 [TBL] [Abstract][Full Text] [Related]
10. Validation of a photoplethysmography device for detection of obstructive sleep apnea in the perioperative setting. Faßbender P; Haddad A; Bürgener S; Peters J J Clin Monit Comput; 2019 Apr; 33(2):341-345. PubMed ID: 29749570 [TBL] [Abstract][Full Text] [Related]
11. Validation of the MediByte® type 3 portable monitor compared with polysomnography for screening of obstructive sleep apnea. Driver HS; Pereira EJ; Bjerring K; Toop F; Stewart SC; Munt PW; Fitzpatrick MF Can Respir J; 2011; 18(3):137-43. PubMed ID: 21766076 [TBL] [Abstract][Full Text] [Related]
12. Validation of Embletta portable diagnostic system for identifying patients with suspected obstructive sleep apnoea syndrome (OSAS). Ng SS; Chan TO; To KW; Ngai J; Tung A; Ko FW; Hui DS Respirology; 2010 Feb; 15(2):336-42. PubMed ID: 20199644 [TBL] [Abstract][Full Text] [Related]
13. An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea. Goodrich S; Orr WC Sleep Med; 2009 Jan; 10(1):118-22. PubMed ID: 18083629 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of the Arabic version of STOP-Bang questionnaire as a screening tool for obstructive sleep apnea. Alhouqani S; Al Manhali M; Al Essa A; Al-Houqani M Sleep Breath; 2015 Dec; 19(4):1235-40. PubMed ID: 25758298 [TBL] [Abstract][Full Text] [Related]
15. A comparison of polysomnography and the SleepStrip in the diagnosis of OSA. Pang KP; Dillard TA; Blanchard AR; Gourin CG; Podolsky R; Terris DJ Otolaryngol Head Neck Surg; 2006 Aug; 135(2):265-8. PubMed ID: 16890080 [TBL] [Abstract][Full Text] [Related]
16. Validation of the Nox-T3 Portable Monitor for Diagnosis of Obstructive Sleep Apnea in Chinese Adults. Xu L; Han F; Keenan BT; Kneeland-Szanto E; Yan H; Dong X; Chang Y; Zhao L; Zhang X; Li J; Pack AI; Kuna ST J Clin Sleep Med; 2017 May; 13(5):675-683. PubMed ID: 28356181 [TBL] [Abstract][Full Text] [Related]
17. Screening for obstructive sleep apnea using a contact-free system compared with polysomnography. Zhao R; Xue J; Dong XS; Zhi H; Chen J; Zhao L; Zhang X; Li J; Penzel T; Han F J Clin Sleep Med; 2021 May; 17(5):1075-1082. PubMed ID: 33576734 [TBL] [Abstract][Full Text] [Related]
18. Validation of a portable recording device (ApneaLink) for identifying patients with suspected obstructive sleep apnoea syndrome. Ng SS; Chan TO; To KW; Ngai J; Tung A; Ko FW; Hui DS Intern Med J; 2009 Nov; 39(11):757-62. PubMed ID: 19220528 [TBL] [Abstract][Full Text] [Related]
19. Screening for obstructive sleep apnea among hospital outpatients. Hug M; Uehli K; Solbach S; Brighenti-Zogg S; Dürr S; Maier S; Leuppi JD; Miedinger D PLoS One; 2018; 13(5):e0198315. PubMed ID: 29847582 [TBL] [Abstract][Full Text] [Related]