These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

290 related articles for article (PubMed ID: 26270750)

  • 21. A biomechanical study comparing polyaxial locking screw mechanisms.
    Hebert-Davies J; Laflamme GY; Rouleau D; Canet F; Sandman E; Li A; Petit Y
    Injury; 2013 Oct; 44(10):1358-62. PubMed ID: 23849980
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Locked plating of comminuted distal femur fractures: does unlocked screw placement affect stability and failure?
    Cui S; Bledsoe JG; Israel H; Watson JT; Cannada LK
    J Orthop Trauma; 2014 Feb; 28(2):90-6. PubMed ID: 23860132
    [TBL] [Abstract][Full Text] [Related]  

  • 23. How much do locked screws add to the fixation of "hybrid" plate constructs in osteoporotic bone?
    Freeman AL; Tornetta P; Schmidt A; Bechtold J; Ricci W; Fleming M
    J Orthop Trauma; 2010 Mar; 24(3):163-9. PubMed ID: 20182252
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Volar fixed-angle plating of distal radius fractures: screws versus pegs--a biomechanical study in a cadaveric model.
    Mehling I; Klitscher D; Mehling AP; Nowak TE; Sternstein W; Rommens PM; Müller LP
    J Orthop Trauma; 2012 Jul; 26(7):395-401. PubMed ID: 22011636
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Does a polyaxial-locking system confer benefits for osteosynthesis of the distal fibula: A cadaver study.
    Hallbauer J; Klos K; Gräfenstein A; Simons P; Rausch S; Mückley T; Hofmann GO
    Orthop Traumatol Surg Res; 2016 Sep; 102(5):645-9. PubMed ID: 27179630
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Development of polyaxial locking plate screw system of sacroiliac joint].
    Fan W; Xie X; Zhou S; Zhang Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1091-5. PubMed ID: 25509772
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical comparison of mono- and bicortical screws in an experimentally induced gap fracture.
    Demner D; Garcia TC; Serdy MG; Hayashi K; Nir BA; Stover SM
    Vet Comp Orthop Traumatol; 2014; 27(6):422-9. PubMed ID: 25327936
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.
    Dougherty PJ; Kim DG; Meisterling S; Wybo C; Yeni Y
    J Orthop Trauma; 2008 Jul; 22(6):399-403. PubMed ID: 18594304
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study.
    Looft JM; Corrêa L; Patel M; Rawlings M; Ackland DC
    ANZ J Surg; 2017 Nov; 87(11):915-920. PubMed ID: 28922701
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Long-term stability of angle-stable versus conventional locked intramedullary nails in distal tibia fractures.
    Wähnert D; Stolarczyk Y; Hoffmeier KL; Raschke MJ; Hofmann GO; Mückley T
    BMC Musculoskelet Disord; 2013 Feb; 14():66. PubMed ID: 23425016
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Antiglide plating of vertical medial malleolus fractures provides stiffer initial fixation than bicortical or unicortical screw fixation.
    Wegner AM; Wolinsky PR; Robbins MA; Garcia TC; Maitra S; Amanatullah DF
    Clin Biomech (Bristol, Avon); 2016 Jan; 31():29-32. PubMed ID: 26482240
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
    Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
    Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of fibular plate fixation on rotational stability of simulated distal tibial fractures treated with intramedullary nailing.
    Kumar A; Charlebois SJ; Cain EL; Smith RA; Daniels AU; Crates JM
    J Bone Joint Surg Am; 2003 Apr; 85(4):604-8. PubMed ID: 12672833
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Finite element analysis of the stability of AO/OTA 43-C1 type distal tibial fractures treated with distal tibia medial anatomic plate versus anterolateral anatomic plate.
    Oken OF; Yildirim AO; Asilturk M
    Acta Orthop Traumatol Turc; 2017 Oct; 51(5):404-408. PubMed ID: 28986074
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Complex distal humerus fractures-comparison of polyaxial locking and nonlocking screw configurations-a preliminary biomechanical study.
    Hungerer S; Wipf F; von Oldenburg G; Augat P; Penzkofer R
    J Orthop Trauma; 2014 Mar; 28(3):130-6. PubMed ID: 23736772
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanics of the Injured Fibula Following Plate Fixation of a Concomitant Tibia Fracture To Fix or Not to Fix?
    Onyekwelu I; Sinicrope BJ; Riehl JT; Roberts CS; Voor MJ
    Bull Hosp Jt Dis (2013); 2018 Sep; 76(3):176-182. PubMed ID: 31513521
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.
    Richter H; Plecko M; Andermatt D; Frigg R; Kronen PW; Klein K; Nuss K; Ferguson SJ; Stöckle U; von Rechenberg B
    J Bone Joint Surg Am; 2015 Feb; 97(3):208-15. PubMed ID: 25653321
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.
    Ockert B; Pedersen V; Geyer L; Wirth S; Mutschler W; Grote S
    Eur J Orthop Surg Traumatol; 2014 Jul; 24(5):747-52. PubMed ID: 24253956
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of augmentation methods for internal fixation of osteoporotic ankle fractures.
    Panchbhavi VK; Vallurupalli S; Morris R
    Foot Ankle Int; 2009 Jul; 30(7):696-703. PubMed ID: 19589319
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical comparison of distal femoral fracture fixation: Analysis of non-locked, locked, and far-cortical locked constructs.
    Riedel MD; Oppizzi G; O'Hara NN; Zhang C; Koh K; Slobogean GP; Zhang LQ; O'Toole RV
    J Orthop Res; 2020 Dec; 38(12):2573-2579. PubMed ID: 32470168
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.