These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 2627259)

  • 1. An explanation of the noncorrespondence between assessment methods of cyclosporin.
    Randleff-Rasmussen GM; Oosthuizen MM; Myburgh JA
    Transpl Int; 1989 Dec; 2(4):181-6. PubMed ID: 2627259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Overestimation of cyclosporin-A levels, using the polyclonal and monoclonal RIA, increased due to the accumulation of crossreactive metabolites.
    Oosthuizen MM; Lambrechts H; Randleff-Rasmussen GM; Myburgh JA
    Transplant Proc; 1989 Feb; 21(1 Pt 1):895-7. PubMed ID: 2650292
    [No Abstract]   [Full Text] [Related]  

  • 3. The determination of metabolite M17 and its meaning for immunosuppressive cyclosporin therapy.
    Khoschsorur G; Auer T; Lanzer G; Petritsch P; Holzer H; Tscheliessnigg KH
    Angiology; 1998 Apr; 49(4):307-14. PubMed ID: 9555934
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monoclonal antibodies for radioimmunoassay of cyclosporine: a multicenter comparison of their performance with the Sandoz polyclonal radioimmunoassay kit.
    Holt DW; Johnston A; Marsden JT; Vernillet L; Keown PA; Rosano TG; Shaw LM; Rosenthaler J
    Clin Chem; 1988 Jun; 34(6):1091-6. PubMed ID: 3288374
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A validation study of selected methods routinely used for measurement of cyclosporine.
    Blick KE; Melouk SH; Fry HD; Gillum RL
    Clin Chem; 1990 Apr; 36(4):670-4. PubMed ID: 1969776
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An optimized method for measuring cyclosporin A with 125I-labeled cyclosporin.
    Felder RA; Mifflin TE; Bastani B
    Clin Chem; 1986 Jul; 32(7):1378-82. PubMed ID: 3521944
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Slow accumulation of cyclosporin metabolites as measured by specific and nonspecific cyclosporin RIA.
    Keller F; Kunzendorf U; Walz G; Schwarz A; Offermann G
    Int J Clin Pharmacol Ther Toxicol; 1990 Apr; 28(4):167-75. PubMed ID: 2338370
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of cyclosporine in plasma from patients with various transplants: HPLC radioimmunoassay with a specific monoclonal antibody compared.
    McBride JH; Rodgerson DO; Park SS; Reyes AF
    Clin Chem; 1989 Aug; 35(8):1726-30. PubMed ID: 2667807
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative analyses of cyclosporine in whole blood and plasma by radioimmunoassay, fluorescence polarization immunoassay, and high-performance liquid chromatography.
    Lindholm A; Henricsson S
    Ther Drug Monit; 1990 Jul; 12(4):344-52. PubMed ID: 2396308
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation and comparison of therapeutic monitoring of whole-blood levels of cyclosporin A and its metabolites in renal transplantation by HPLC and RIA methods.
    Safarcík K; Brozmanová H; Bartos V; Jegorov A; Grundmann M
    Clin Chim Acta; 2001 Aug; 310(2):165-71. PubMed ID: 11498082
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cyclosporine determinations in heart and kidney transplant patients: comparison of high-performance liquid chromatography, polyclonal, and monoclonal methods.
    Subbarao MN; Swanson JR; Mueggler PA
    Ther Drug Monit; 1989; 11(1):53-6. PubMed ID: 2643203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of cyclosporin G (Nva2-cyclosporin) concentrations measured in whole blood by monoclonal fluorescence polarization immunoassay, monoclonal radioimmunoassay, and HPLC.
    Annesley TM; Coombs RC; Orsulak PJ
    Clin Chem; 1993 Jun; 39(6):1050-3. PubMed ID: 8504536
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cyclosporine kinetics in renal transplant patients as assessed by high-performance liquid chromatography and radioimmunoassay using monoclonal and polyclonal antibodies.
    Speck RF; Frey FJ; Frey BM
    Transplantation; 1989 May; 47(5):802-6. PubMed ID: 2655217
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of cyclosporin A (CsA) concentrations by fluorescence polarization immunoassay (FPIA): comparison with radio immunoassay (RIA) and liquid chromatography (HPLC).
    Mraz W; Müller C; Molnar B; Knedel M
    Transplant Proc; 1989 Feb; 21(1 Pt 1):885-7. PubMed ID: 2650289
    [No Abstract]   [Full Text] [Related]  

  • 15. Therapeutic cyclosporine monitoring: comparison of radioimmunoassay and high-performance liquid chromatography methods in organ transplant recipients.
    Hirvisalo EL; Kivistö KT; Neuvonen PJ
    Ther Drug Monit; 1990 Jul; 12(4):353-8. PubMed ID: 2396309
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of cyclosporin A measurement in whole blood by six different methods.
    Tjandra-Maga B; Verbesselt R; Scharpé S; Verkerk R; Lambert WE; Van Liedekerke B; De Leenheer A
    J Clin Chem Clin Biochem; 1990 Jan; 28(1):53-7. PubMed ID: 2313238
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation and comparison of radioimmunoassay methods using monoclonal or polyclonal antibodies for the assay of cyclosporine in blood samples.
    Zucchelli GC; Clerico A; Pilo A; Masini S; Zoppi F; Bovati ML; Gazzetti P; Giovannini L; Bertelli AA
    Int J Tissue React; 1989; 11(6):315-20. PubMed ID: 2699881
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of nonspecific radioimmunoassay, high-performance liquid chromatography, and fluorescence polarization immunoassay for cyclosporine monitoring in renal transplantation.
    Lee SF; Yang WC; Shann TY; Lui WY; Wang RB
    Ther Drug Monit; 1991 Mar; 13(2):152-6. PubMed ID: 2053123
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Therapeutic monitoring of cyclosporine: impact of a change in standards on 125I-monoclonal RIA performance in comparison with liquid chromatography.
    Keown PA; Glenn J; Denegri J; Maciejewska U; Seccombe D; Stawecki M; Freeman D; Stiller C; Shackleton C; Cameron E
    Clin Chem; 1990 May; 36(5):804-7. PubMed ID: 2337993
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reversed-phase high-performance liquid chromatography determination of cyclosporin in human blood.
    Sangalli L; Bonati M
    Ther Drug Monit; 1987 Sep; 9(3):353-7. PubMed ID: 3672581
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.