These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 2627384)
1. Intraoperative cortical somatosensory evoked potentials for detection of sciatic neuropathy during total hip arthroplasty. Porter SS; Black DL; Reckling FW; Mason J J Clin Anesth; 1989; 1(3):170-6. PubMed ID: 2627384 [TBL] [Abstract][Full Text] [Related]
2. Somatosensory-evoked potential monitored during total hip arthroplasty. Black DL; Reckling FW; Porter SS Clin Orthop Relat Res; 1991 Jan; (262):170-7. PubMed ID: 1984914 [TBL] [Abstract][Full Text] [Related]
3. Surgical maneuvers placing the sciatic nerve at risk during total hip arthroplasty as assessed by somatosensory evoked potential monitoring. Pereles TR; Stuchin SA; Kastenbaum DM; Beric A; Lacagnino G; Kabir H J Arthroplasty; 1996 Jun; 11(4):438-44. PubMed ID: 8792251 [TBL] [Abstract][Full Text] [Related]
4. Upper-limb somatosensory evoked potential monitoring in lumbosacral spine surgery: a prognostic marker for position-related ulnar nerve injury. Chung I; Glow JA; Dimopoulos V; Walid MS; Smisson HF; Johnston KW; Robinson JS; Grigorian AA Spine J; 2009 Apr; 9(4):287-95. PubMed ID: 18684675 [TBL] [Abstract][Full Text] [Related]
5. Risk of sciatic nerve traction injury during hip arthroscopy—is it the amount or duration? An intraoperative nerve monitoring study. Telleria JJ; Safran MR; Harris AH; Gardi JN; Glick JM J Bone Joint Surg Am; 2012 Nov; 94(22):2025-32. PubMed ID: 23052834 [TBL] [Abstract][Full Text] [Related]
6. The use of somatosensory evoked potential during revision or reoperation for total hip arthroplasty. Nercessian OA; Gonzalez EG; Stinchfield FE Clin Orthop Relat Res; 1989 Jun; (243):138-42. PubMed ID: 2721053 [TBL] [Abstract][Full Text] [Related]
8. Intraoperative neurophysiological monitoring of somatosensory evoked potentials during hip arthroscopy surgery. Ochs BC; Herzka A; Yaylali I Neurodiagn J; 2012 Dec; 52(4):312-9. PubMed ID: 23301281 [TBL] [Abstract][Full Text] [Related]
9. The monitoring of somatosensory evoked potentials and neurologic complications in aneurysm surgery. Min KT; Kim JH; Shin YS; Kwon SY; Nam YT Yonsei Med J; 2001 Apr; 42(2):227-32. PubMed ID: 11371112 [TBL] [Abstract][Full Text] [Related]
10. A Pilot Study of a Novel Automated Somatosensory Evoked Potential (SSEP) Monitoring Device for Detection and Prevention of Intraoperative Peripheral Nerve Injury in Total Shoulder Arthroplasty Surgery. Chui J; Murkin JM; Drosdowech D J Neurosurg Anesthesiol; 2019 Jul; 31(3):291-298. PubMed ID: 29787402 [TBL] [Abstract][Full Text] [Related]
11. "Threshold-level" multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring. Calancie B; Harris W; Broton JG; Alexeeva N; Green BA J Neurosurg; 1998 Mar; 88(3):457-70. PubMed ID: 9488299 [TBL] [Abstract][Full Text] [Related]
12. Somatosensory evoked potentials help prevent positioning-related brachial plexus injury during skull base surgery. Jellish WS; Sherazee G; Patel J; Cunanan R; Steele J; Garibashvilli K; Baldwin M; Anderson D; Leonetti JP Otolaryngol Head Neck Surg; 2013 Jul; 149(1):168-73. PubMed ID: 23520073 [TBL] [Abstract][Full Text] [Related]
13. The effects from lumbar nerve root transection in rats on spinal somatosensory and motor-evoked potentials. Jou IM Spine (Phila Pa 1976); 2004 Jan; 29(2):147-55. PubMed ID: 14722405 [TBL] [Abstract][Full Text] [Related]
14. Sciatic neuropathy secondary to migration of trochanteric wire following total hip arthroplasty. Asnis SE; Hanley S; Shelton PD Clin Orthop Relat Res; 1985 Jun; (196):226-8. PubMed ID: 3888469 [TBL] [Abstract][Full Text] [Related]
15. Delayed sciatic nerve palsy following total hip arthroplasty. Cohen B; Bhamra M; Ferris BD Br J Clin Pract; 1991; 45(4):292-3. PubMed ID: 1667266 [TBL] [Abstract][Full Text] [Related]
17. A Novel Automated Somatosensory Evoked Potential (SSEP) Monitoring Device for Detection of Intraoperative Peripheral Nerve Injury in Cardiac Surgery: A Clinical Feasibility Study. Chui J; Murkin JM; Turkstra T; McKenzie N; Guo L; Quantz M J Cardiothorac Vasc Anesth; 2017 Aug; 31(4):1174-1182. PubMed ID: 28159523 [TBL] [Abstract][Full Text] [Related]
18. Somatosensory evoked potential monitoring in the surgical management of acute acetabular fractures. Helfet DL; Hissa EA; Sergay S; Mast JW J Orthop Trauma; 1991; 5(2):161-6. PubMed ID: 1861191 [TBL] [Abstract][Full Text] [Related]
19. Monitoring electrophysiologic function during carotid endarterectomy: a comparison of somatosensory evoked potentials and conventional electroencephalogram. Lam AM; Manninen PH; Ferguson GG; Nantau W Anesthesiology; 1991 Jul; 75(1):15-21. PubMed ID: 2064043 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of sciatic nerve compromise during total hip arthroplasty. Stone RG; Weeks LE; Hajdu M; Stinchfield FE Clin Orthop Relat Res; 1985 Dec; (201):26-31. PubMed ID: 4064413 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]