BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 26283555)

  • 21. The effect of the buttonhole method vs. the traditional method of AV fistula cannulation on hemostasis, needle stick pain, pre-needle stick anxiety, and presence of aneurysms in ambulatory patients on hemodialysis.
    Pergolotti A; Rich E; Lock K
    Nephrol Nurs J; 2011; 38(4):333-6. PubMed ID: 21928609
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The buttonhole technique for fistula cannulation: pros and cons.
    Atkar RK; MacRae JM
    Curr Opin Nephrol Hypertens; 2013 Nov; 22(6):629-36. PubMed ID: 24076555
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Buttonhole technique better than area puncture technique on hemostasis and pain associated with needle cannulation.
    Sukthinthai N; Sittipraneet A; Tummanittayangkoon B; Vasuvattakul S; Chanchairujira T
    J Med Assoc Thai; 2012 Feb; 95 Suppl 2():S208-12. PubMed ID: 22574551
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Buttonhole versus Stepladder Cannulation for Home Hemodialysis: A Multicenter, Randomized, Pilot Trial.
    Huang SS; MacRae J; Ross D; Imtiaz R; Hollingsworth B; Nesrallah GE; Copland MA; McFarlane PA; Chan CT; Zimmerman D
    Clin J Am Soc Nephrol; 2019 Mar; 14(3):403-410. PubMed ID: 30659057
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Infectious complications following conversion to buttonhole cannulation of native arteriovenous fistulas: a quality improvement report.
    Labriola L; Crott R; Desmet C; André G; Jadoul M
    Am J Kidney Dis; 2011 Mar; 57(3):442-8. PubMed ID: 21216513
    [TBL] [Abstract][Full Text] [Related]  

  • 26. "Everyone should buttonhole": a novel technique for a regional Australian renal service.
    Hartig V; Smyth W
    J Ren Care; 2009 Sep; 35(3):114-9. PubMed ID: 19689692
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Buttonhole cannulation technique in a patient with keloid scarred skin on home hemodialysis: a case study.
    Donato-Moore S
    Nephrol Nurs J; 2011; 38(1):60-3; quiz 64. PubMed ID: 21469555
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pro: Buttonhole cannulation of arteriovenous fistulae.
    Nesrallah GE
    Nephrol Dial Transplant; 2016 Apr; 31(4):520-3. PubMed ID: 26994293
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cannulating in haemodialysis: rope-ladder or buttonhole technique?
    Verhallen AM; Kooistra MP; van Jaarsveld BC
    Nephrol Dial Transplant; 2007 Sep; 22(9):2601-4. PubMed ID: 17557776
    [TBL] [Abstract][Full Text] [Related]  

  • 30. SHARP VERSUS BLUNT DIALYSIS NEEDLE USE WITH BUTTONHOLE METHOD: OPEN RANDOMISED TRIAL.
    Morselli C; Chiari P; Aliberti T; Celli G; Catalani S; Miale I; Melandri V; Bianchi L
    J Ren Care; 2015 Dec; 41(4):213-21. PubMed ID: 25819209
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Infectious complications following conversion to buttonhole cannulation.
    Labriola L; Jadoul M
    Clin Nephrol; 2011 Nov; 76(5):423; author reply 424. PubMed ID: 22000566
    [No Abstract]   [Full Text] [Related]  

  • 32. Believing in the buttonhole technique.
    Kregness A
    Nephrol News Issues; 2008 Nov; 22(12):36, 40, 42. PubMed ID: 19105515
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The salvage of aneurysmal fistulae utilizing a modified buttonhole cannulation technique and multiple cannulators.
    Marticorena RM; Hunter J; Macleod S; Petershofer E; Dacouris N; Donnelly S; Goldstein MB
    Hemodial Int; 2006 Apr; 10(2):193-200. PubMed ID: 16623674
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Initial experience with the buttonhole technique in a Brazilian hemodialysis center.
    Silva Gdos S; Silva RA; Nicolino AM; Pavanetti LC; Alasmar VL; Guzzardi R; Zanolli MB; Guilhen JC; Araújo Ide M
    J Bras Nefrol; 2010; 32(3):257-62. PubMed ID: 21103688
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Buttonhole cannulation--an unexpected outcome.
    Doss S; Schiller B; Moran J
    Nephrol Nurs J; 2008; 35(4):417-9. PubMed ID: 18783005
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Assessment of blood flow in hemodialysis patients using buttonhole technique for arteriovenous fistula by ultrasound dilution.
    Krairittichai U; Leetrakulpanich B
    J Med Assoc Thai; 2012 Mar; 95 Suppl 3():S62-8. PubMed ID: 22619889
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.
    van Loon MM; Goovaerts T; Kessels AG; van der Sande FM; Tordoir JH
    Nephrol Dial Transplant; 2010 Jan; 25(1):225-30. PubMed ID: 19717827
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A randomised controlled trial of buttonhole cannulation for the prevention of fistula access complications.
    Chow J; Rayment G; San Miguel S; Gilbert M
    J Ren Care; 2011 Jun; 37(2):85-93. PubMed ID: 21561544
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The role of buttonhole cannulation.
    Nephrol News Issues; 2015 Jan; 29(1):20-1. PubMed ID: 26473248
    [No Abstract]   [Full Text] [Related]  

  • 40. Buttonhole cannulation in hemodialysis: improved outcomes and increased expense--is it worth it?
    Ludlow V
    CANNT J; 2010; 20(1):29-37. PubMed ID: 20426358
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.