These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

75 related articles for article (PubMed ID: 2628536)

  • 1. .5 per cent plain bupivacaine for spinal anaesthesia effects of posture.
    Vichitvejpaisal P; Svastdi-Xuto O
    J Med Assoc Thai; 1989 Dec; 72(12):687-91. PubMed ID: 2628536
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Plain or hyperbaric bupivacaine for spinal anesthesia.
    Stienstra R; van Poorten JF
    Anesth Analg; 1987 Feb; 66(2):171-6. PubMed ID: 3813061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of hemodynamic and anesthetic effects of hyperbaric bupivacaine and tetracaine in spinal anesthesia.
    Nishiyama T; Komatsu K; Hanaoka K
    J Anesth; 2003; 17(4):218-22. PubMed ID: 14625707
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prospective study on reproducibility of the spread of spinal anesthesia using plain 0.5% bupivacaine.
    Taivainen TR; Tuominen MK; Kuulasmaa KA; Rosenberg PH
    Reg Anesth; 1990; 15(1):12-4. PubMed ID: 2275905
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of patient posture during puncture on successful unilateral spinal anaesthesia in outpatient lower abdominal surgery.
    Al Malyan M; Becchi C; Falsini S; Lorenzi P; Boddi V; Marsili M; Boncinelli S
    Eur J Anaesthesiol; 2006 Jun; 23(6):491-5. PubMed ID: 16507180
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Epidural volume extension and intrathecal dose requirement: plain versus hyperbaric bupivacaine.
    Tyagi A; Kumar A; Sethi AK; Mohta M
    Anesth Analg; 2008 Jul; 107(1):333-8. PubMed ID: 18635505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Clinical research of hyperbaric, isobaric, and hypobaric solutions of bupivacaine in continuous spinal anesthesia].
    Yang HW; Bai NY; Guo QL
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2005 Feb; 30(1):84-7. PubMed ID: 15871196
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spread of spinal anaesthesia with 0.5% bupivacaine: influence of the vertebral interspace and speed of injection.
    Chin KW; Chin NM; Chin MK
    Med J Malaysia; 1994 Jun; 49(2):142-8. PubMed ID: 8090093
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Spinal anesthesia with isobaric bupivacaine for percutaneous nephro-ureterolithotomy].
    Terachi T; Terai A; Machida S
    Hinyokika Kiyo; 1987 Dec; 33(12):2016-9. PubMed ID: 3448927
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spinal anaesthesia with hypobaric 0.19% or plain 0.5% bupivacaine.
    Taivainen T; Tuominen M; Rosenberg PH
    Br J Anaesth; 1990 Aug; 65(2):234-6. PubMed ID: 2223342
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bupivacaine in spinal anaesthesia.
    Pentti OM; Kähönen T; Stenvall P
    Ann Chir Gynaecol; 1978; 67(5):185-9. PubMed ID: 369449
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of baricity and mass of bupivacaine solutions in spinal anesthesia.
    Siaens A; De Rood M
    Acta Anaesthesiol Belg; 1987; 38(1):89-95. PubMed ID: 3591271
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hyperbaric bupivacaine for spinal anesthesia in cesarean section.
    Santos A; Pedersen H; Finster M; Edström H
    Anesth Analg; 1984 Nov; 63(11):1009-13. PubMed ID: 6496970
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Prolongation of Bupivacaine spinal anaesthesia by oral and intramuscular Clonidine].
    Dziubdziela W; Jałowiecki P; Kawecki P
    Wiad Lek; 2003; 56(11-12):520-6. PubMed ID: 15058157
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Bupivacaine in spinal anesthesia. The spread of analgesia--dependence on baricity, positioning, dosage, technique of injection and patient characteristics].
    Thage B; Callesen T
    Ugeskr Laeger; 1993 Sep; 155(39):3104-8. PubMed ID: 8212398
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Body mass and spread of spinal anesthesia with bupivacaine.
    Pitkänen MT
    Anesth Analg; 1987 Feb; 66(2):127-31. PubMed ID: 3813056
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of baricity on the outcome of spinal anesthesia with bupivacaine for lumbar spine surgery.
    Tetzlaff JE; O'Hara J; Bell G; Grimm K; Yoon HJ
    Reg Anesth; 1995; 20(6):533-7. PubMed ID: 8608073
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of epidural volume extension on spinal block with hyperbaric or plain bupivacaine for Caesarean delivery.
    Kucukguclu S; Unlugenc H; Gunenc F; Kuvaki B; Gokmen N; Gunasti S; Guclu S; Yilmaz F; Isik G
    Eur J Anaesthesiol; 2008 Apr; 25(4):307-13. PubMed ID: 17888192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Barbotage and spinal anaesthesia. The effect of barbotage on the spread of analgesia during isobaric spinal anaesthesia.
    Nightingale PJ
    Anaesthesia; 1983 Jan; 38(1):7-9. PubMed ID: 6824158
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Spread of spinal anesthesia with 0.5% isobaric bupivacaine].
    Hirabayashi Y; Shimizu R; Saitoh K; Fukuda H; Nakaigawa Y; Saitoh J; Ikeno S; Horiguchi Y; Togashi H; Mitsuhata H
    Masui; 1993 Nov; 42(11):1628-34. PubMed ID: 8254872
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.