These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

239 related articles for article (PubMed ID: 26287445)

  • 21. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength.
    Bottlang M; Doornink J; Fitzpatrick DC; Madey SM
    J Bone Joint Surg Am; 2009 Aug; 91(8):1985-94. PubMed ID: 19651958
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Locked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough?
    Hak DJ; Althausen P; Hazelwood SJ
    J Orthop Trauma; 2010 Apr; 24(4):207-11. PubMed ID: 20335752
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical properties of plate constructs for feline ilial fracture gap stabilization.
    Schmierer PA; Smolders LA; Zderic I; Gueorguiev B; Pozzi A; Knell SC
    Vet Surg; 2019 Jan; 48(1):88-95. PubMed ID: 30422336
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical evaluation of locking plate radial shaft fixation: unicortical locking fixation versus mixed bicortical and unicortical fixation in a sawbone model.
    Roberts JW; Grindel SI; Rebholz B; Wang M
    J Hand Surg Am; 2007 Sep; 32(7):971-5. PubMed ID: 17826548
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ex Vivo Biomechanical Comparison of Titanium Locking Plate, Stainless Steel Nonlocking Plate, and Tie-in External Fixator Applied by a Dorsal Approach on Ostectomized Humeri of Pigeons (
    Darrow BG; Weigel JP; Greenacre CB; Xie X; Liaw PK; Biskup JJ
    J Avian Med Surg; 2019 Mar; 33(1):29-37. PubMed ID: 31124609
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study.
    Looft JM; Corrêa L; Patel M; Rawlings M; Ackland DC
    ANZ J Surg; 2017 Nov; 87(11):915-920. PubMed ID: 28922701
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical Comparison of Two Locking Plate Constructs Under Cyclic Loading in Four-Point Bending in a Fracture Gap Model: Two Screws versus Three Screws Per Fragment.
    Palierne S; Froidefond B; Swider P; Autefage A
    Vet Comp Orthop Traumatol; 2019 Jan; 32(1):59-66. PubMed ID: 30646412
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
    Cullen AB; Curtiss S; Lee MA
    J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Complex distal humerus fractures-comparison of polyaxial locking and nonlocking screw configurations-a preliminary biomechanical study.
    Hungerer S; Wipf F; von Oldenburg G; Augat P; Penzkofer R
    J Orthop Trauma; 2014 Mar; 28(3):130-6. PubMed ID: 23736772
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical evaluation of periprosthetic femoral fracture fixation.
    Zdero R; Walker R; Waddell JP; Schemitsch EH
    J Bone Joint Surg Am; 2008 May; 90(5):1068-77. PubMed ID: 18451400
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Proximal Screw Configuration Alters Peak Plate Strain Without Changing Construct Stiffness in Comminuted Supracondylar Femur Fractures.
    McLachlin S; Kreder H; Ng M; Jenkinson R; Whyne C; Larouche J
    J Orthop Trauma; 2017 Dec; 31(12):e418-e424. PubMed ID: 28902085
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture.
    Shanmugam R; Jian CYCCS; Haseeb A; Aik S
    J Orthop Surg (Hong Kong); 2018; 26(3):2309499018802511. PubMed ID: 30270746
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Hybrid locked plating of osteoporotic fractures of the humerus.
    Gardner MJ; Griffith MH; Demetrakopoulos D; Brophy RH; Grose A; Helfet DL; Lorich DG
    J Bone Joint Surg Am; 2006 Sep; 88(9):1962-7. PubMed ID: 16951112
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimizing Hybrid Plate Fixation with a Locked, Oblique End Screw in Osteoporotic Fractures.
    Wynkoop A; Ndubaku O; Charpentier PM; Peck JB; Walter NE; Atkinson P
    Iowa Orthop J; 2017; 37():11-17. PubMed ID: 28852328
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures.
    Worhacz K; Nayak AN; Boudreaux RL; Pavan B; Wipf Dipl-Ing F; Jacofsky MC; Araghi A
    J Orthop Trauma; 2018 Dec; 32(12):e462-e468. PubMed ID: 30252778
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical comparison of bicortical locking versus unicortical far-cortex-abutting locking screw-plate fixation for comminuted radial shaft fractures.
    Overturf SJ; Morris RP; Gugala Z; Lindsey RW
    J Hand Surg Am; 2014 Oct; 39(10):1907-13. PubMed ID: 25149898
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical evaluation of locking plate fixation with hybrid screw constructs in analogue humeri.
    Dunlap JT; Lucas GL; Chong AC; Cooke FW; Tiruvadi V
    Am J Orthop (Belle Mead NJ); 2011 Feb; 40(2):E20-5. PubMed ID: 21720590
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.
    Windolf M; Klos K; Wähnert D; van der Pol B; Radtke R; Schwieger K; Jakob RP
    BMC Musculoskelet Disord; 2010 May; 11():95. PubMed ID: 20492707
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
    Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion.
    Henschel J; Tsai S; Fitzpatrick DC; Marsh JL; Madey SM; Bottlang M
    J Orthop Trauma; 2017 Oct; 31(10):531-537. PubMed ID: 28657927
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.