BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 26292332)

  • 1. Acoustic Source Analysis of Magnetoacoustic Tomography With Magnetic Induction for Conductivity Gradual-Varying Tissues.
    Wang J; Zhou Y; Sun X; Ma Q; Zhang D
    IEEE Trans Biomed Eng; 2016 Apr; 63(4):758-64. PubMed ID: 26292332
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conductivity Anisotropy Influence on Acoustic Sources for Magnetoacoustic Tomography With Magnetic Induction.
    Yu Z; Dai S; Ma Q; Guo G; Tu J; Zhang D
    IEEE Trans Biomed Eng; 2018 Nov; 65(11):2512-2518. PubMed ID: 29993525
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Acoustic dipole radiation based electrical impedance contrast imaging approach of magnetoacoustic tomography with magnetic induction.
    Sun X; Fang D; Zhang D; Ma Q
    Med Phys; 2013 May; 40(5):052902. PubMed ID: 23635295
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Image reconstruction of conductivity on magnetoacoustic tomography with magnetic induction].
    Li J; Yin T; Liu Z; Xu G
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Apr; 27(2):416-20. PubMed ID: 20481330
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Numerical study of magnetoacoustic signal generation with magnetic induction based on inhomogeneous conductivity anisotropy.
    Li X; Hu S; Li L; Zhu S
    Comput Math Methods Med; 2013; 2013():161357. PubMed ID: 23606896
    [TBL] [Abstract][Full Text] [Related]  

  • 6. B-scan based acoustic source reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI).
    Mariappan L; Li X; He B
    IEEE Trans Biomed Eng; 2011 Mar; 58(3):713-20. PubMed ID: 21097372
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI).
    Li X; Xu Y; He B
    IEEE Trans Biomed Eng; 2007 Feb; 54(2):323-30. PubMed ID: 17278589
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnetoacoustic tomography with magnetic induction (MAT-MI) for electrical conductivity imaging.
    Li X; He B
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():3173-6. PubMed ID: 19964795
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet.
    Mariappan L; Hu G; He B
    Med Phys; 2014 Feb; 41(2):022902. PubMed ID: 24506649
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Magnetoacoustic tomography with magnetic induction (MAT-MI) for imaging electrical conductivity of biological tissue: a tutorial review.
    Li X; Yu K; He B
    Phys Med Biol; 2016 Sep; 61(18):R249-R270. PubMed ID: 27542088
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A study of acoustic source generation mechanism of Magnetoacoustic Tomography.
    Wang S; Zhang S; Ma R; Yin T; Liu Z
    Comput Med Imaging Graph; 2014 Jan; 38(1):42-8. PubMed ID: 24238804
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Solving the forward problem of magnetoacoustic tomography with magnetic induction by means of the finite element method.
    Li X; Li X; Zhu S; He B
    Phys Med Biol; 2009 May; 54(9):2667-82. PubMed ID: 19351978
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction.
    Ma Q; He B
    Phys Med Biol; 2007 Aug; 52(16):5085-99. PubMed ID: 17671355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Numerical simulation of endoscopic magnetoacoustic tomography with magnetic induction.
    Zheng S; Zhen M
    Comput Biol Med; 2017 Nov; 90():1-14. PubMed ID: 28910689
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Simulation research on magnetoacoustic effect and thermoacoustic effect of pulsed magnetic excitation].
    Yang Y; Liu G; Xia Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2017 Feb; 34(1):21-6. PubMed ID: 29717582
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence on acoustic frequency characteristics of conductivity gradual-varying tissue in magnetoacoustic tomography (MAT).
    Zhao X; Liu G; Yan X; Chen X; Chen S
    Comput Biol Med; 2019 Jan; 104():105-110. PubMed ID: 30468913
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of electrical anisotropy during magnetoacoustic tomography with magnetic induction.
    Brinker K; Roth BJ
    IEEE Trans Biomed Eng; 2008 May; 55(5):1637-9. PubMed ID: 18440910
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetoacoustic tomography with magnetic induction: bioimepedance reconstruction through vector source imaging.
    Mariappan L; He B
    IEEE Trans Med Imaging; 2013 Mar; 32(3):619-27. PubMed ID: 23322761
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison study of three different image reconstruction algorithms for MAT-MI.
    Xia R; Li X; He B
    IEEE Trans Biomed Eng; 2010 Mar; 57(3):708-13. PubMed ID: 19846363
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multi-excitation magnetoacoustic tomography with magnetic induction for bioimpedance imaging.
    Li X; He B
    IEEE Trans Med Imaging; 2010 Oct; 29(10):1759-67. PubMed ID: 20529729
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.