These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
138 related articles for article (PubMed ID: 26301676)
1. Percutaneous coronary intervention with RACER renal stents in very large diameter coronary arteries. Harnett DT; Maze R; Pourdjabbar A; Ramirez FD; Simard T; Di Santo P; Gallagher S; Singh K; So D; Le May MR; Labinaz M; Hibbert B; Chong AY; Glover C; Int J Cardiol; 2015 Dec; 201():342-4. PubMed ID: 26301676 [No Abstract] [Full Text] [Related]
2. Drug-coated balloon without stent implantation for chronic total occlusion of coronary arteries: Description of a new strategy with an optical coherence tomography assistance. Cortese B; Buccheri D; Piraino D; Silva-Orrego P Int J Cardiol; 2015 Jul; 191():75-6. PubMed ID: 25965604 [No Abstract] [Full Text] [Related]
3. Guiding-catheter thrombectomy combined with distal protection during primary percutaneous coronary intervention of a saphenous vein graft. García-Tejada J; Jurado-Román A; Hernández F; Asenjo RM; de Nicolás JM; Albarrán A; Velázquez M; Tascón J Cardiovasc Revasc Med; 2013; 14(6):356-8. PubMed ID: 24267597 [TBL] [Abstract][Full Text] [Related]
5. A modified technique of balloon anchoring for tricky stent delivery. Aeby G; Surmely JF; Togni M; Cook S EuroIntervention; 2013 Jan; 8(9):1099-102. PubMed ID: 23339816 [No Abstract] [Full Text] [Related]
6. Provisional main branch stenting with drug-eluting stents after drug-eluting balloon treatment of the side branch: a simple and durable technique for treating bifurcation lesions. McCutcheon K; Garda R; Mkhwanazi L; Vachiat A; Ramjee R; Moosa J; Tsabedze N; Karolia S; Manga P Int J Cardiol; 2015 Mar; 182():294-6. PubMed ID: 25585366 [No Abstract] [Full Text] [Related]
7. RACER renal stents for large diameter left main coronary artery intervention. Pourdjabbar A; Hibbert B; Simard T; Ramirez D; Glover C; O'Brien E Int J Cardiol; 2012 May; 156(3):e68-70. PubMed ID: 21925748 [No Abstract] [Full Text] [Related]
8. The Mechanism of Balloon Impact in Percutaneous Transluminal Coronary Angioplasty in Eccentric Coronary Artery Narrowings. Saner H; Saner B; Meier B Am J Cardiol; 2021 May; 146():128-131. PubMed ID: 33548188 [TBL] [Abstract][Full Text] [Related]
9. Successful Stent Delivery Through a Slaloming Coronary Path. Aznaouridis K; Bonou M; Masoura K; Vaina S; Vlachopoulos C; Tousoulis D J Invasive Cardiol; 2019 Feb; 31(2):E43. PubMed ID: 30700632 [TBL] [Abstract][Full Text] [Related]
10. Stent Choice in Very Large Left Main Lesions in 3 Patients. Lozano I; Rondan J; Vegas JM; Segovia E Tex Heart Inst J; 2017 Oct; 44(5):353-356. PubMed ID: 29259510 [TBL] [Abstract][Full Text] [Related]
11. Trapped rotablation wire causing longitudinal stent deformation. Lempereur M; Bogale N; Fung A Can J Cardiol; 2014 Jan; 30(1):146.e5-7. PubMed ID: 24365197 [TBL] [Abstract][Full Text] [Related]
12. Early experience with a new approach for percutaneous intervention of totally occluded saphenous vein graft: is the flow the best thrombolytic? Fiorina C; Meliga E; Chizzola G; Curello S; Tayeh O; Vizzardi E; Dei Cas L; Ettori F EuroIntervention; 2010 Sep; 6(4):461-6. PubMed ID: 20884433 [TBL] [Abstract][Full Text] [Related]
13. Saphenous vein graft perforation during percutaneous coronary intervention: a case series. Marmagkiolis K; Brilakis ES; Hakeem A; Cilingiroglu M; Bilodeau L J Invasive Cardiol; 2013 Mar; 25(3):157-61. PubMed ID: 23468449 [TBL] [Abstract][Full Text] [Related]
14. Management of radial artery perforation during transradial catheterization using a polytetrafluoroethylene-covered coronary stent. Chatterjee A; White JS; Leesar MA Cardiovasc Revasc Med; 2017 Mar; 18(2):133-135. PubMed ID: 27591152 [TBL] [Abstract][Full Text] [Related]
15. Safety and effectiveness of drug-eluting versus bare-metal stents in saphenous vein bypass graft percutaneous coronary interventions: insights from the Veterans Affairs CART program. Aggarwal V; Stanislawski MA; Maddox TM; Nallamothu BK; Grunwald G; Adams JC; Ho PM; Rao SV; Casserly IP; Rumsfeld JS; Brilakis ES; Tsai TT J Am Coll Cardiol; 2014 Oct; 64(17):1825-36. PubMed ID: 25443706 [TBL] [Abstract][Full Text] [Related]
16. Late outcomes of drug eluting and bare metal stents in saphenous vein graft percutaneous coronary intervention. Nair S; Fath-Ordoubadi F; Clarke B; El-Omar M; Foley J; Fraser DG; Mahadevan VS; Neyses L; Khattar RS; Mamas MA EuroIntervention; 2011 Mar; 6(8):985-91. PubMed ID: 21330247 [TBL] [Abstract][Full Text] [Related]
17. Immediate stent recoil in an anastomotic vein graft lesion treated by cutting balloon angioplasty. Akkus NI; Budeepalli J; Cilingiroglu M Rev Port Cardiol; 2013 Nov; 32(11):935-9. PubMed ID: 24238890 [TBL] [Abstract][Full Text] [Related]
18. Transradial percutaneous coronary intervention with Stentys self-apposing stents and Stentys-Yew technique for angulated and ectatic coronary artery. Yew KL; Kang Z Int J Cardiol; 2015 Apr; 185():150-2. PubMed ID: 25795207 [No Abstract] [Full Text] [Related]
19. A case with successful retrograde stent delivery via AC branch for tortuous right coronary artery. Uehara Y; Shimizu M; Yoshimura M J Invasive Cardiol; 2013 Feb; 25(2):E39-41. PubMed ID: 23388238 [TBL] [Abstract][Full Text] [Related]
20. Successful transradial removal of an inflated coronary stent dislodged from the right coronary ostium. Porto I; Larosa C; Rosa I; Burzotta F; Trani C Cardiovasc Revasc Med; 2014; 15(8):432-5. PubMed ID: 24929473 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]