These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Correcting heat-induced chemical shift distortions in proton resonance frequency-shift thermometry. Gaur P; Partanen A; Werner B; Ghanouni P; Bitton R; Butts Pauly K; Grissom WA Magn Reson Med; 2016 Jul; 76(1):172-82. PubMed ID: 26301458 [TBL] [Abstract][Full Text] [Related]
4. Improved MRI thermometry with multiple-echo spirals. Marx M; Butts Pauly K Magn Reson Med; 2016 Sep; 76(3):747-56. PubMed ID: 26332512 [TBL] [Abstract][Full Text] [Related]
5. Temperature-induced tissue susceptibility changes lead to significant temperature errors in PRFS-based MR thermometry during thermal interventions. Sprinkhuizen SM; Konings MK; van der Bom MJ; Viergever MA; Bakker CJ; Bartels LW Magn Reson Med; 2010 Nov; 64(5):1360-72. PubMed ID: 20648685 [TBL] [Abstract][Full Text] [Related]
6. Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: phantom and clinical feasibility studies. Cernicanu A; Lepetit-Coiffe M; Roland J; Becker CD; Terraz S NMR Biomed; 2008 Oct; 21(8):849-58. PubMed ID: 18574794 [TBL] [Abstract][Full Text] [Related]
8. 3D MR thermometry of frozen tissue: Feasibility and accuracy during cryoablation at 3T. Overduin CG; Fütterer JJ; Scheenen TW J Magn Reson Imaging; 2016 Dec; 44(6):1572-1579. PubMed ID: 27160336 [TBL] [Abstract][Full Text] [Related]
9. Crushed rephased orthogonal slice selection (CROSS) for simultaneous acquisition of two orthogonal proton resonance frequency temperature maps. Krafft AJ; Rauschenberg J; Maier F; Jenne JW; Bock M J Magn Reson Imaging; 2013 Dec; 38(6):1510-20. PubMed ID: 23677906 [TBL] [Abstract][Full Text] [Related]
10. Compensating for magnetic field inhomogeneity in multigradient-echo-based MR thermometry. Simonis FF; Petersen ET; Bartels LW; Lagendijk JJ; van den Berg CA Magn Reson Med; 2015 Mar; 73(3):1184-9. PubMed ID: 24664621 [TBL] [Abstract][Full Text] [Related]
11. A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and measured 3-D temperature data sets. Nadobny J; Wlodarczyk W; Westhoff L; Gellermann J; Felix R; Wust P IEEE Trans Biomed Eng; 2005 Mar; 52(3):505-19. PubMed ID: 15759581 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of a three-dimensional MR acoustic radiation force imaging pulse sequence using a novel unbalanced bipolar motion encoding gradient. de Bever JT; Odéen H; Todd N; Farrer AI; Parker DL Magn Reson Med; 2016 Sep; 76(3):803-13. PubMed ID: 26445135 [TBL] [Abstract][Full Text] [Related]
13. Dual-echo Z-shimmed proton resonance frequency-shift magnetic resonance thermometry near metallic ablation probes: Technique and temperature precision. Zhang Y; Poorman ME; Grissom WA Magn Reson Med; 2017 Dec; 78(6):2299-2306. PubMed ID: 28185304 [TBL] [Abstract][Full Text] [Related]
14. Dual-Pathway sequences for MR thermometry: When and where to use them. Ciris PA; Cheng CC; Mei CS; Panych LP; Madore B Magn Reson Med; 2017 Mar; 77(3):1193-1200. PubMed ID: 26968318 [TBL] [Abstract][Full Text] [Related]
15. Correction of proton resonance frequency shift MR-thermometry errors caused by heat-induced magnetic susceptibility changes during high intensity focused ultrasound ablations in tissues containing fat. Baron P; Deckers R; de Greef M; Merckel LG; Bakker CJ; Bouwman JG; Bleys RL; van den Bosch MA; Bartels LW Magn Reson Med; 2014 Dec; 72(6):1580-9. PubMed ID: 24347129 [TBL] [Abstract][Full Text] [Related]
16. Flexible proton 3D MR spectroscopic imaging of the prostate with low-power adiabatic pulses for volume selection and spiral readout. Steinseifer IK; Philips BW; Gagoski B; Weiland E; Scheenen TW; Heerschap A Magn Reson Med; 2017 Mar; 77(3):928-935. PubMed ID: 26968422 [TBL] [Abstract][Full Text] [Related]
17. Three-dimensional spatial and temporal temperature imaging in gel phantoms using backscattered ultrasound. Anand A; Savéry D; Hall C IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jan; 54(1):23-31. PubMed ID: 17225797 [TBL] [Abstract][Full Text] [Related]
18. Motion correction in MR thermometry of abdominal organs: a comparison of the referenceless vs. the multibaseline approach. de Senneville BD; Roujol S; Moonen C; Ries M Magn Reson Med; 2010 Nov; 64(5):1373-81. PubMed ID: 20677237 [TBL] [Abstract][Full Text] [Related]
19. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom. Gellermann J; Wlodarczyk W; Ganter H; Nadobny J; Fähling H; Seebass M; Felix R; Wust P Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):267-77. PubMed ID: 15629620 [TBL] [Abstract][Full Text] [Related]
20. Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound. Odéen H; Todd N; Diakite M; Minalga E; Payne A; Parker DL Med Phys; 2014 Sep; 41(9):092301. PubMed ID: 25186406 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]