These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
739 related articles for article (PubMed ID: 26302945)
21. Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants. Hu H; Dietz M Trends Hear; 2015 Dec; 19():. PubMed ID: 26631108 [TBL] [Abstract][Full Text] [Related]
22. Localization and interaural time difference (ITD) thresholds for cochlear implant recipients with preserved acoustic hearing in the implanted ear. Gifford RH; Grantham DW; Sheffield SW; Davis TJ; Dwyer R; Dorman MF Hear Res; 2014 Jun; 312():28-37. PubMed ID: 24607490 [TBL] [Abstract][Full Text] [Related]
23. Cortical representation of interaural time difference in congenital deafness. Tillein J; Hubka P; Syed E; Hartmann R; Engel AK; Kral A Cereb Cortex; 2010 Feb; 20(2):492-506. PubMed ID: 19906808 [TBL] [Abstract][Full Text] [Related]
24. Restoration of cortical symmetry and binaural function: Cortical auditory evoked responses in adult cochlear implant users with single sided deafness. Wedekind A; Rajan G; Van Dun B; Távora-Vieira D PLoS One; 2020; 15(1):e0227371. PubMed ID: 31935234 [TBL] [Abstract][Full Text] [Related]
25. Neural ITD Sensitivity and Temporal Coding with Cochlear Implants in an Animal Model of Early-Onset Deafness. Chung Y; Buechel BD; Sunwoo W; Wagner JD; Delgutte B J Assoc Res Otolaryngol; 2019 Feb; 20(1):37-56. PubMed ID: 30623319 [TBL] [Abstract][Full Text] [Related]
26. Sound Source Localization by Cochlear Implant Recipients with Normal Hearing in the Contralateral Ear: Effects of Spectral Content and Duration of Listening Experience. Dillon MT; Rooth MA; Canfarotta MW; Richter ME; Thompson NJ; Brown KD Audiol Neurootol; 2022; 27(6):437-448. PubMed ID: 35439753 [TBL] [Abstract][Full Text] [Related]
27. The effect of interaural differences in envelope shape on the perceived location of sounds (L). Francart T; Lenssen A; Wouters J J Acoust Soc Am; 2012 Aug; 132(2):611-4. PubMed ID: 22894182 [TBL] [Abstract][Full Text] [Related]
28. Effects of stimulation level and electrode pairing on the binaural interaction component of the electrically evoked auditory brain stem response. He S; Brown CJ; Abbas PJ Ear Hear; 2010 Aug; 31(4):457-70. PubMed ID: 20418771 [TBL] [Abstract][Full Text] [Related]
29. Preliminary results of the relationship between the binaural interaction component of the electrically evoked auditory brainstem response and interaural pitch comparisons in bilateral cochlear implant recipients. He S; Brown CJ; Abbas PJ Ear Hear; 2012; 33(1):57-68. PubMed ID: 21730858 [TBL] [Abstract][Full Text] [Related]
30. Envelope enhancement increases cortical sensitivity to interaural envelope delays with acoustic and electric hearing. Hartley DE; Isaiah A PLoS One; 2014; 9(8):e104097. PubMed ID: 25093417 [TBL] [Abstract][Full Text] [Related]
31. Sensitivity to interaural time differences with combined cochlear implant and acoustic stimulation. Francart T; Brokx J; Wouters J J Assoc Res Otolaryngol; 2009 Mar; 10(1):131-41. PubMed ID: 19048344 [TBL] [Abstract][Full Text] [Related]
32. Assessing binaural/bimodal advantages using auditory event-related potentials in subjects with cochlear implants. Sasaki T; Yamamoto K; Iwaki T; Kubo T Auris Nasus Larynx; 2009 Oct; 36(5):541-6. PubMed ID: 19297109 [TBL] [Abstract][Full Text] [Related]
33. Prognostic value of electrically evoked auditory brainstem responses in cochlear implantation. Lundin K; Stillesjö F; Rask-Andersen H Cochlear Implants Int; 2015 Sep; 16(5):254-61. PubMed ID: 25798647 [TBL] [Abstract][Full Text] [Related]
34. Interaural frequency mismatch jointly modulates neural brainstem binaural interaction and behavioral interaural time difference sensitivity in humans. Sammeth CA; Brown AD; Greene NT; Tollin DJ Hear Res; 2023 Sep; 437():108839. PubMed ID: 37429100 [TBL] [Abstract][Full Text] [Related]
35. Brainstem auditory evoked potentials with the use of acoustic clicks and complex verbal sounds in young adults with learning disabilities. Kouni SN; Giannopoulos S; Ziavra N; Koutsojannis C Am J Otolaryngol; 2013; 34(6):646-51. PubMed ID: 23953938 [TBL] [Abstract][Full Text] [Related]
36. Sensitivity to interaural time differences and localization accuracy in cochlear implant users with combined electric-acoustic stimulation. Körtje M; Baumann U; Stöver T; Weissgerber T PLoS One; 2020; 15(10):e0241015. PubMed ID: 33075114 [TBL] [Abstract][Full Text] [Related]
37. Dissociated Representation of Binaural Cues in Single-Sided Deafness: Implications for Cochlear Implantation. Hubka P; Schmidt L; Tillein J; Baumhoff P; Konerding W; Land R; Sato M; Kral A J Neurosci; 2024 Jul; 44(28):. PubMed ID: 38830759 [TBL] [Abstract][Full Text] [Related]
38. Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants. Smith ZM; Delgutte B J Assoc Res Otolaryngol; 2007 Mar; 8(1):134-51. PubMed ID: 17225976 [TBL] [Abstract][Full Text] [Related]
40. [Detection of the electric brain stem auditory response before cochlear implantation and its significance]. Wang B; Cao KL; Wei CG; Wang Y; Li H Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2016 Nov; 51(11):826-831. PubMed ID: 27938608 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]