These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
374 related articles for article (PubMed ID: 26304736)
21. A loop-tendon suture for tendon transfer or graft surgery. Kim SH; Chung MS; Baek GH; Lee YH; Lee S; Gong HS J Hand Surg Am; 2007 Mar; 32(3):367-72. PubMed ID: 17336845 [TBL] [Abstract][Full Text] [Related]
22. The Mechanical Strength of Side-to-Side Tendon Repair Using a Modified Krackow Technique. Ueno K; Suzuki T; Matsuura Y; Sukegawa K; Ohtori S; Kuniyoshi K J Hand Surg Asian Pac Vol; 2021 Jun; 26(2):188-193. PubMed ID: 33928850 [No Abstract] [Full Text] [Related]
23. A biomechanical study of pediatric flexor profundus tendon repair. Comparing the tensile strengths of 3 suture techniques. Al-Thunayan TA; Al-Zahrani MT; Hakeem AA; Al-Zahrani FM; Al-Qattan MM Saudi Med J; 2016 Sep; 37(9):957-62. PubMed ID: 27570850 [TBL] [Abstract][Full Text] [Related]
24. Analysis of a knotless flexor tendon repair using a multifilament stainless steel cable-crimp system. Gordon L; Matsui J; McDonald E; Gordon JA; Neimkin R J Hand Surg Am; 2013 Apr; 38(4):677-83. PubMed ID: 23453895 [TBL] [Abstract][Full Text] [Related]
25. Comparison of a multifilament stainless steel suture with FiberWire for flexor tendon repairs--an in vitro biomechanical study. McDonald E; Gordon JA; Buckley JM; Gordon L J Hand Surg Eur Vol; 2013 May; 38(4):418-23. PubMed ID: 22745156 [TBL] [Abstract][Full Text] [Related]
26. Tendon With Z-Lengthening Technique and Construct Assessment: A Biomechanical Study for Use in Tendon Reconstructions. Weller WJ; Goldstein Z; Li F; Aljawad A; Greenberg JA J Hand Surg Am; 2020 Jul; 45(7):661.e1-661.e10. PubMed ID: 32063347 [TBL] [Abstract][Full Text] [Related]
27. A biomechanical comparison of 3 loop suture materials in a 6-strand flexor tendon repair technique. Gan AW; Neo PY; He M; Yam AK; Chong AK; Tay SC J Hand Surg Am; 2012 Sep; 37(9):1830-4. PubMed ID: 22857910 [TBL] [Abstract][Full Text] [Related]
28. The effects of A1 pulley release after flexor tendon repair in a cadaveric model. Buonocore SD; Broer PN; Kaldany A; Sawh-Martinez R; Thomson JG Plast Reconstr Surg; 2012 Oct; 130(4):857-864. PubMed ID: 22691846 [TBL] [Abstract][Full Text] [Related]
29. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair. Lawrence TM; Davis TR J Hand Surg Am; 2005 Jul; 30(4):836-41. PubMed ID: 16039381 [TBL] [Abstract][Full Text] [Related]
30. Comparison of Flexor Tendon Repair Between 6-Strand Lim-Tsai With 4-Strand Cruciate and Becker Technique. Wong YR; Lee CS; Loke AM; Liu X; Suzana MJ I; Tay SC J Hand Surg Am; 2015 Sep; 40(9):1806-11. PubMed ID: 26142080 [TBL] [Abstract][Full Text] [Related]
31. Tensile strength of a new suture for fixation of tendon grafts when using a weave technique. Tanaka T; Zhao C; Ettema AM; Zobitz ME; An KN; Amadio PC J Hand Surg Am; 2006; 31(6):982-6. PubMed ID: 16843160 [TBL] [Abstract][Full Text] [Related]
32. The effect of sliding knots on the suture-tendon interface strength: a biomechanical analysis comparing sliding and static arthroscopic knots. Savage AJ; Spruiell MD; Schwertz JM; McGwin G; Eberhardt A; Ponce BA Am J Sports Med; 2013 Feb; 41(2):296-301. PubMed ID: 23299852 [TBL] [Abstract][Full Text] [Related]
33. In Vivo Evaluation of the Mechanical Strength of a Slide Lengthening Technique With a Locking Mechanism Using a Rabbit Model. Iwase D; Uchida K; Metoki Y; Sekiguchi H; Aikawa J; Matsuo T; Matsuo A; Takaso M Cureus; 2020 Dec; 12(12):e12387. PubMed ID: 33409106 [TBL] [Abstract][Full Text] [Related]
34. Changes in tendon strength after partial cut and effects of running peripheral sutures. Tan J; Wang B; Tan B; Xu Y; Tang JB J Hand Surg Br; 2003 Oct; 28(5):478-82. PubMed ID: 12954261 [TBL] [Abstract][Full Text] [Related]
35. Biomechanical Study Comparing Pulvertaft, Double Side-to-Side, and Locking Side-to-Side Tendon Suture Techniques. Koopman JE; Hundepool CA; Duraku LS; Kreulen M; Zuidam JM J Hand Surg Am; 2021 Mar; 46(3):246.e1-246.e7. PubMed ID: 33250284 [TBL] [Abstract][Full Text] [Related]
36. Biomechanical evaluation of various suture configurations in side-to-side tenorrhaphy. Wagner E; Ortiz C; Wagner P; Guzman R; Ahumada X; Maffulli N J Bone Joint Surg Am; 2014 Feb; 96(3):232-6. PubMed ID: 24500585 [TBL] [Abstract][Full Text] [Related]
37. Comparative mechanical analysis of dorsal versus palmar placement of core suture for flexor tendon repairs. Soejima O; Diao E; Lotz JC; Hariharan JS J Hand Surg Am; 1995 Sep; 20(5):801-7. PubMed ID: 8522748 [TBL] [Abstract][Full Text] [Related]
38. Evaluation of a new 4-strand flexor tendon repair in a cadaveric porcine model. Manchio JV; Shashikant MP; Shrivastava A; Weinzweig J; Vernadakis AJ J Hand Surg Am; 2009 Jan; 34(1):102-7. PubMed ID: 19058923 [TBL] [Abstract][Full Text] [Related]
39. Effects of PDGF-BB delivery from heparinized collagen sutures on the healing of lacerated chicken flexor tendon in vivo. Younesi M; Knapik DM; Cumsky J; Donmez BO; He P; Islam A; Learn G; McClellan P; Bohl M; Gillespie RJ; Akkus O Acta Biomater; 2017 Nov; 63():200-209. PubMed ID: 28890257 [TBL] [Abstract][Full Text] [Related]
40. Adeno-associated virus-2-mediated bFGF gene transfer to digital flexor tendons significantly increases healing strength. an in vivo study. Tang JB; Cao Y; Zhu B; Xin KQ; Wang XT; Liu PY J Bone Joint Surg Am; 2008 May; 90(5):1078-89. PubMed ID: 18451401 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]