These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 26305688)

  • 1. Evaluation of the main coagulation tests in the presence of hemolysis in healthy subjects and patients on oral anticoagulant therapy.
    D'Angelo G; Villa C; Tamborini A; Villa S
    Int J Lab Hematol; 2015 Dec; 37(6):819-33. PubMed ID: 26305688
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of Hemolysis on Routine Coagulation Tests when Tested on an Optical Coagulation Analyzer.
    Yang H; Zhao Y; Guo S; He J; Peng L; Wang Y; Zhang G; Jiang Y
    Clin Lab; 2023 Aug; 69(8):. PubMed ID: 37560849
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of specimen hemolysis on coagulation test results.
    Laga AC; Cheves TA; Sweeney JD
    Am J Clin Pathol; 2006 Nov; 126(5):748-55. PubMed ID: 17050072
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of hemolysis and lipemia interference on kaolin-activated thromboelastography, and comparison with conventional coagulation tests.
    Tang N; Jin X; Sun Z; Jian C
    Scand J Clin Lab Invest; 2017 Apr; 77(2):98-103. PubMed ID: 28218013
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transition from argatroban to oral anticoagulation with phenprocoumon or acenocoumarol: effects on prothrombin time, activated partial thromboplastin time, and Ecarin Clotting Time.
    Harder S; Graff J; Klinkhardt U; von Hentig N; Walenga JM; Watanabe H; Osakabe M; Breddin HK
    Thromb Haemost; 2004 Jun; 91(6):1137-45. PubMed ID: 15175800
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?
    Rimac V; Coen Herak D
    Int J Lab Hematol; 2017 Oct; 39(5):475-481. PubMed ID: 28488785
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Centrifuge Temperature on Routine Coagulation Tests.
    Yazar H; Özdemir F; Köse E
    Acta Haematol; 2018; 139(3):158-163. PubMed ID: 29550825
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of apixaban on commonly used coagulation assays: results from the Belgian national External Quality Assessment Scheme.
    Van Blerk M; Bailleul E; Chatelain B; Demulder A; Devreese K; Douxfils J; Jacquemin M; Jochmans K; Mullier F; Wijns W; China B; Vernelen K; Soumali MR
    Int J Lab Hematol; 2017 Aug; 39(4):402-408. PubMed ID: 28304137
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Point-of-care coagulation testing for assessment of the pharmacodynamic anticoagulant effect of direct oral anticoagulant.
    Mani H; Herth N; Kasper A; Wendt T; Schuettfort G; Weil Y; Pfeilschifter W; Linnemann B; Herrmann E; Lindhoff-Last E
    Ther Drug Monit; 2014 Oct; 36(5):624-31. PubMed ID: 24577124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of dabigatran and rivaroxaban on routine coagulation assays. A nationwide Belgian survey.
    Van Blerk M; Bailleul E; Chatelain B; Demulder A; Devreese K; Douxfils J; Jochmans K; Mullier F; Wijns W; Soumali MR; Coucke W; Vernelen K; Van de Walle P
    Thromb Haemost; 2015 Jan; 113(1):154-64. PubMed ID: 25231101
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of an automated hemostasis testing analyzer, the Trombolyzer Combi.
    Ermens AA; Bury JG; Wijn-Maas EC
    Clin Lab; 2000; 46(9-10):463-7. PubMed ID: 11034531
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of the minimal citrate tube fill volume for routine coagulation tests on ACL TOP 500 CTS®.
    Ver Elst K; Vermeiren S; Schouwers S; Callebaut V; Thomson W; Weekx S
    Int J Lab Hematol; 2013 Dec; 35(6):614-9. PubMed ID: 23663653
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of hemolysis, bilirubin, and lipemia interference on coagulation tests detected by two analytical systems.
    Nougier C; Jousselme E; Sobas F; Pousseur V; Négrier C
    Int J Lab Hematol; 2020 Feb; 42(1):88-94. PubMed ID: 31846202
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of mechanical hemolysis of blood on two D-dimer immunoassays.
    Lippi G; Avanzini P; Zobbi V; Ippolito L
    Blood Coagul Fibrinolysis; 2012 Jul; 23(5):461-3. PubMed ID: 22576291
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of the oral, direct thrombin inhibitor dabigatran on five common coagulation assays.
    Lindahl TL; Baghaei F; Blixter IF; Gustafsson KM; Stigendal L; Sten-Linder M; Strandberg K; Hillarp A;
    Thromb Haemost; 2011 Feb; 105(2):371-8. PubMed ID: 21103660
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Interference of lipemia in samples for routine coagulation testing using a Sysmex CS-5100 coagulometer.
    Negrini D; Bernardi D; Antonelli G; Plebani M
    Int J Lab Hematol; 2019 Dec; 41(6):772-777. PubMed ID: 31508901
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Revisiting the effects of spectral interfering substances in optical end-point coagulation assays.
    Seheult JN; Dalenberg D; Sridharan MR; Stuart M; Moericke K; Cardel L; Heikal N; Chen D; Pruthi RK
    Int J Lab Hematol; 2021 Oct; 43(5):1181-1190. PubMed ID: 33455065
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of freezing plasma at -20°C for 2 weeks on prothrombin time, activated partial thromboplastin time, dilute Russell viper venom time, activated protein C resistance, and D-dimer levels.
    Foshat M; Bates S; Russo W; Huerta A; Albright K; Giddings K; Indrikovs A; Qian YW
    Clin Appl Thromb Hemost; 2015 Jan; 21(1):41-7. PubMed ID: 24842886
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of coagulation tests in patients on therapeutic doses of rivaroxaban. A cross-sectional pharmacodynamic study based on peak and trough plasma levels.
    Francart SJ; Hawes EM; Deal AM; Adcock DM; Gosselin R; Jeanneret C; Friedman KD; Moll S
    Thromb Haemost; 2014 Jun; 111(6):1133-40. PubMed ID: 24401946
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.
    Kitchen S; Woolley A
    Blood Coagul Fibrinolysis; 2013 Jan; 24(1):28-34. PubMed ID: 23249565
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.