These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 26313737)
21. Sci-Sat AM: Brachy - 12: Resolving the olefinic lipid resonance from water in proton magnetic resonance spectra of vertebral bone marrow at 3 T. Yahya A; Troitskaia A; Fallone BG Med Phys; 2012 Jul; 39(7Part4):4647. PubMed ID: 28516641 [TBL] [Abstract][Full Text] [Related]
22. A phase rotation scheme for achieving very short echo times with localized stimulated echo spectroscopy. Knight-Scott J; Shanbhag DD; Dunham SA Magn Reson Imaging; 2005 Oct; 23(8):871-6. PubMed ID: 16275426 [TBL] [Abstract][Full Text] [Related]
23. 1H-MRS of hepatic fat using short TR at 3T: SNR optimization and fast T2 relaxometry. Gambarota G; Tanner M; van der Graaf M; Mulkern RV; Newbould RD MAGMA; 2011 Dec; 24(6):339-45. PubMed ID: 21892734 [TBL] [Abstract][Full Text] [Related]
24. Reproducibility of 7-T brain spectroscopy using an ultrashort echo time STimulated Echo Acquisition Mode sequence and automated voxel repositioning. Reid MA; Forloines MR; Salibi N NMR Biomed; 2022 Feb; 35(2):e4631. PubMed ID: 34622996 [TBL] [Abstract][Full Text] [Related]
25. Quantitative analysis of T2-correction in single-voxel magnetic resonance spectroscopy of hepatic lipid fraction. Sharma P; Martin DR; Pineda N; Xu Q; Vos M; Anania F; Hu X J Magn Reson Imaging; 2009 Mar; 29(3):629-35. PubMed ID: 19243059 [TBL] [Abstract][Full Text] [Related]
26. Characterization of hepatic fatty acids in mice with reduced liver fat by ultra-short echo time (1)H-MRS at 14.1 T in vivo. Soares AF; Lei H; Gruetter R NMR Biomed; 2015 Aug; 28(8):1009-20. PubMed ID: 26119835 [TBL] [Abstract][Full Text] [Related]
27. In vivo proton magnetic resonance spectroscopy of liver metabolites in non-alcoholic fatty liver disease in rats: T2 relaxation times in methylene protons. Song KH; Baek HM; Lee DW; Choe BY Chem Phys Lipids; 2015 Oct; 191():1-7. PubMed ID: 26200917 [TBL] [Abstract][Full Text] [Related]
28. SPECIAL semi-LASER with lipid artifact compensation for 1H MRS at 7 T. Fuchs A; Luttje M; Boesiger P; Henning A Magn Reson Med; 2013 Mar; 69(3):603-12. PubMed ID: 22517487 [TBL] [Abstract][Full Text] [Related]
29. Hepatic fat quantification using chemical shift MR imaging and MR spectroscopy in the presence of hepatic iron deposition: validation in phantoms and in patients with chronic liver disease. Lee SS; Lee Y; Kim N; Kim SW; Byun JH; Park SH; Lee MG; Ha HK J Magn Reson Imaging; 2011 Jun; 33(6):1390-8. PubMed ID: 21591008 [TBL] [Abstract][Full Text] [Related]
30. Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner. Springer F; Martirosian P; Schwenzer NF; Szimtenings M; Kreisler P; Claussen CD; Schick F Invest Radiol; 2008 Nov; 43(11):802-8. PubMed ID: 18923260 [TBL] [Abstract][Full Text] [Related]
31. [In vivo proton MR spectroscopy of normal liver parenchyma: technique and results]. Müller C; Hübner F; Bisdas S; Herzog C; Hammerstingl RM; Ackermann H; Vorbuchner M; Vogl TJ Rofo; 2006 Nov; 178(11):1128-36. PubMed ID: 17128381 [TBL] [Abstract][Full Text] [Related]
32. In vivo magnetic resonance spectroscopy detection of combined glutamate-glutamine in healthy upper cervical cord at 3 T. Solanky BS; Abdel-Aziz K; Yiannakas MC; Berry AM; Ciccarelli O; Wheeler-Kingshott CA NMR Biomed; 2013 Mar; 26(3):357-66. PubMed ID: 23281170 [TBL] [Abstract][Full Text] [Related]
33. MR spectroscopy of liver in overweight children and adolescents: investigation of ¹H T₂ relaxation times at 3T. Chabanova E; Bille DS; Thisted E; Holm JC; Thomsen HS Eur J Radiol; 2012 May; 81(5):811-4. PubMed ID: 21377308 [TBL] [Abstract][Full Text] [Related]
34. Ultralong TE In Vivo Gajdošík M; Hingerl L; Škoch A; Freudenthaler A; Krumpolec P; Ukropec J; Ukropcová B; Šedivý P; Hájek M; Itariu BK; Maier B; Baumgartner-Parzer S; Krebs M; Trattnig S; Krššák M J Magn Reson Imaging; 2019 Jul; 50(1):71-82. PubMed ID: 30578581 [TBL] [Abstract][Full Text] [Related]
35. MR imaging of the lungs: value of short TE spin-echo pulse sequences. Mayo JR; MacKay A; Müller NL AJR Am J Roentgenol; 1992 Nov; 159(5):951-6. PubMed ID: 1414805 [TBL] [Abstract][Full Text] [Related]
36. Fast Padé transform for increasing the signal to noise ratio of spectra provided by STEAM pulse sequence. Saeedi-Moghadam M; Pouladian M; Faghihi R; Lotfi M Technol Health Care; 2019; 27(2):167-172. PubMed ID: 30562913 [TBL] [Abstract][Full Text] [Related]
37. Could assessment of glioma methylene lipid resonance by in vivo (1)H-MRS be of clinical value? Murphy PS; Rowland IJ; Viviers L; Brada M; Leach MO; Dzik-Jurasz AS Br J Radiol; 2003 Jul; 76(907):459-63. PubMed ID: 12857705 [TBL] [Abstract][Full Text] [Related]
38. Echo time optimization for in-vivo measurement of unsaturated lipid resonances using J-difference-edited MRS. Lin D; Zhou J; Cao Y; Wang Z; Hsu YC; Zheng F; Li H; Sun S; Ren H; Deng L; Chen F; Wang M Magn Reson Med; 2023 Dec; 90(6):2217-2232. PubMed ID: 37496253 [TBL] [Abstract][Full Text] [Related]
39. 1H MRS of intramyocellular lipids in soleus muscle at 7 T: spectral simplification by using long echo times without water suppression. Ren J; Sherry AD; Malloy CR Magn Reson Med; 2010 Sep; 64(3):662-71. PubMed ID: 20578068 [TBL] [Abstract][Full Text] [Related]