These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 26329201)

  • 1. An ultra-low noise optical head for liquid environment atomic force microscopy.
    Schlesinger I; Kuchuk K; Sivan U
    Rev Sci Instrum; 2015 Aug; 86(8):083705. PubMed ID: 26329201
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wideband low-noise optical beam deflection sensor with photothermal excitation for liquid-environment atomic force microscopy.
    Fukuma T
    Rev Sci Instrum; 2009 Feb; 80(2):023707. PubMed ID: 19256653
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atomic-resolution imaging in liquid by frequency modulation atomic force microscopy using small cantilevers with megahertz-order resonance frequencies.
    Fukuma T; Onishi K; Kobayashi N; Matsuki A; Asakawa H
    Nanotechnology; 2012 Apr; 23(13):135706. PubMed ID: 22421199
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photothermal excitation setup for a modified commercial atomic force microscope.
    Adam H; Rode S; Schreiber M; Kobayashi K; Yamada H; Kühnle A
    Rev Sci Instrum; 2014 Feb; 85(2):023703. PubMed ID: 24593367
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid.
    Nishida S; Kobayashi D; Sakurada T; Nakazawa T; Hoshi Y; Kawakatsu H
    Rev Sci Instrum; 2008 Dec; 79(12):123703. PubMed ID: 19123565
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Modification of a commercial atomic force microscopy for low-noise, high-resolution frequency-modulation imaging in liquid environment.
    Rode S; Stark R; Lübbe J; Tröger L; Schütte J; Umeda K; Kobayashi K; Yamada H; Kühnle A
    Rev Sci Instrum; 2011 Jul; 82(7):073703. PubMed ID: 21806185
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A low noise all-fiber interferometer for high resolution frequency modulated atomic force microscopy imaging in liquids.
    Rasool HI; Wilkinson PR; Stieg AZ; Gimzewski JK
    Rev Sci Instrum; 2010 Feb; 81(2):023703. PubMed ID: 20192498
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Potential of interferometric cantilever detection and its application for SFM/AFM in liquids.
    Hoogenboom BW; Frederix PL; Fotiadis D; Hug HJ; Engel A
    Nanotechnology; 2008 Sep; 19(38):384019. PubMed ID: 21832578
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A high frequency sensor for optical beam deflection atomic force microscopy.
    Enning R; Ziegler D; Nievergelt A; Friedlos R; Venkataramani K; Stemmer A
    Rev Sci Instrum; 2011 Apr; 82(4):043705. PubMed ID: 21529011
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-bandwidth multimode self-sensing in bimodal atomic force microscopy.
    Ruppert MG; Moheimani SO
    Beilstein J Nanotechnol; 2016; 7():284-95. PubMed ID: 26977385
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhancing the optical lever sensitivity of microcantilevers for dynamic atomic force microscopy via integrated low frequency paddles.
    Shaik NH; Reifenberger RG; Raman A
    Nanotechnology; 2016 May; 27(19):195502. PubMed ID: 27040811
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multimodal cantilevers with novel piezoelectric layer topology for sensitivity enhancement.
    Moore SI; Ruppert MG; Yong YK
    Beilstein J Nanotechnol; 2017; 8():358-371. PubMed ID: 28326225
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quadrature phase interferometer for high resolution force spectroscopy.
    Paolino P; Aguilar Sandoval FA; Bellon L
    Rev Sci Instrum; 2013 Sep; 84(9):095001. PubMed ID: 24089852
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The qPlus sensor, a powerful core for the atomic force microscope.
    Giessibl FJ
    Rev Sci Instrum; 2019 Jan; 90(1):011101. PubMed ID: 30709191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improving tapping mode atomic force microscopy with piezoelectric cantilevers.
    Rogers B; Manning L; Sulchek T; Adams JD
    Ultramicroscopy; 2004 Aug; 100(3-4):267-76. PubMed ID: 15231319
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High viscosity environments: an unexpected route to obtain true atomic resolution with atomic force microscopy.
    Weber SA; Kilpatrick JI; Brosnan TM; Jarvis SP; Rodriguez BJ
    Nanotechnology; 2014 May; 25(17):175701. PubMed ID: 24717916
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration.
    Slattery AD; Blanch AJ; Quinton JS; Gibson CT
    Ultramicroscopy; 2013 Aug; 131():46-55. PubMed ID: 23685172
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved atomic force microscopy cantilever performance by partial reflective coating.
    Schumacher Z; Miyahara Y; Aeschimann L; Grütter P
    Beilstein J Nanotechnol; 2015; 6():1450-6. PubMed ID: 26199849
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration of T-shaped atomic force microscope cantilevers using the thermal noise method.
    Kim Y; Mandriota N; Goodnight D; Sahin O
    Rev Sci Instrum; 2020 Aug; 91(8):083703. PubMed ID: 32872926
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiation pressure excitation of a low temperature atomic force/magnetic force microscope for imaging in 4-300 K temperature range.
    Çelik Ü; Karcı Ö; Uysallı Y; Özer HÖ; Oral A
    Rev Sci Instrum; 2017 Jan; 88(1):013705. PubMed ID: 28147654
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.