305 related articles for article (PubMed ID: 26332610)
1. SENSE reconstruction for multiband EPI including slice-dependent N/2 ghost correction.
Hennel F; Buehrer M; von Deuster C; Seuven A; Pruessmann KP
Magn Reson Med; 2016 Sep; 76(3):873-9. PubMed ID: 26332610
[TBL] [Abstract][Full Text] [Related]
2. Dual-polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data.
Hoge WS; Polimeni JR
Magn Reson Med; 2016 Jul; 76(1):32-44. PubMed ID: 26208304
[TBL] [Abstract][Full Text] [Related]
3. Robust SENSE reconstruction of simultaneous multislice EPI with low-rank enhanced coil sensitivity calibration and slice-dependent 2D Nyquist ghost correction.
Lyu M; Barth M; Xie VB; Liu Y; Ma X; Feng Y; Wu EX
Magn Reson Med; 2018 Oct; 80(4):1376-1390. PubMed ID: 29427405
[TBL] [Abstract][Full Text] [Related]
4. Reference-free single-pass EPI Nyquist ghost correction using annihilating filter-based low rank Hankel matrix (ALOHA).
Lee J; Jin KH; Ye JC
Magn Reson Med; 2016 Dec; 76(6):1775-1789. PubMed ID: 26887895
[TBL] [Abstract][Full Text] [Related]
5. PEC-GRAPPA reconstruction of simultaneous multislice EPI with slice-dependent 2D Nyquist ghost correction.
Liu Y; Lyu M; Barth M; Yi Z; Leong ATL; Chen F; Feng Y; Wu EX
Magn Reson Med; 2019 Mar; 81(3):1924-1934. PubMed ID: 30368895
[TBL] [Abstract][Full Text] [Related]
6. Two-dimensional-NGC-SENSE-GRAPPA for fast, ghosting-robust reconstruction of in-plane and slice-accelerated blipped-CAIPI echo planar imaging.
Koopmans PJ
Magn Reson Med; 2017 Mar; 77(3):998-1009. PubMed ID: 26932565
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous multislice accelerated interleaved EPI DWI using generalized blipped-CAIPI acquisition and 3D K-space reconstruction.
Dai E; Ma X; Zhang Z; Yuan C; Guo H
Magn Reson Med; 2017 Apr; 77(4):1593-1605. PubMed ID: 27090059
[TBL] [Abstract][Full Text] [Related]
8. Dynamic 2D self-phase-map Nyquist ghost correction for simultaneous multi-slice echo planar imaging.
Yarach U; Tung YH; Setsompop K; In MH; Chatnuntawech I; Yakupov R; Godenschweger F; Speck O
Magn Reson Med; 2018 Oct; 80(4):1577-1587. PubMed ID: 29427393
[TBL] [Abstract][Full Text] [Related]
9. Robust EPI Nyquist ghost removal by incorporating phase error correction with sensitivity encoding (PEC-SENSE).
Xie VB; Lyu M; Liu Y; Feng Y; Wu EX
Magn Reson Med; 2018 Feb; 79(2):943-951. PubMed ID: 28590562
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.
Liu C; Moseley ME; Bammer R
Magn Reson Med; 2005 Dec; 54(6):1412-22. PubMed ID: 16276497
[TBL] [Abstract][Full Text] [Related]
11. Parallel EPI artifact correction (PEAC) for N/2 ghost suppression in neuroimaging applications.
Li H; Fox-Neff K; Vaughan B; French D; Szaflarski JP; Li Y
Magn Reson Imaging; 2013 Jul; 31(6):1022-8. PubMed ID: 23601363
[TBL] [Abstract][Full Text] [Related]
12. Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.
Hoge WS; Setsompop K; Polimeni JR
Magn Reson Med; 2018 Oct; 80(4):1364-1375. PubMed ID: 29424460
[TBL] [Abstract][Full Text] [Related]
13. EPI Nyquist ghost and geometric distortion correction by two-frame phase labeling.
Xie VB; Lyu M; Wu EX
Magn Reson Med; 2017 May; 77(5):1749-1761. PubMed ID: 27136196
[TBL] [Abstract][Full Text] [Related]
14. Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction.
Chen NK; Wyrwicz AM
Magn Reson Med; 2004 Jun; 51(6):1247-53. PubMed ID: 15170846
[TBL] [Abstract][Full Text] [Related]
15. Multishot cartesian turbo spin-echo diffusion imaging using iterative POCSMUSE Reconstruction.
Zhang Z; Zhang B; Li M; Liang X; Chen X; Liu R; Zhang X; Guo H
J Magn Reson Imaging; 2017 Jul; 46(1):167-174. PubMed ID: 27766699
[TBL] [Abstract][Full Text] [Related]
16. k-Space deep learning for reference-free EPI ghost correction.
Lee J; Han Y; Ryu JK; Park JY; Ye JC
Magn Reson Med; 2019 Dec; 82(6):2299-2313. PubMed ID: 31321809
[TBL] [Abstract][Full Text] [Related]
17. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty.
Setsompop K; Gagoski BA; Polimeni JR; Witzel T; Wedeen VJ; Wald LL
Magn Reson Med; 2012 May; 67(5):1210-24. PubMed ID: 21858868
[TBL] [Abstract][Full Text] [Related]
18. Two-dimensional phase correction method for single and multi-shot echo planar imaging.
Zur Y
Magn Reson Med; 2011 Dec; 66(6):1616-26. PubMed ID: 21574178
[TBL] [Abstract][Full Text] [Related]
19. A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.
Chung JY; Han Y; Cho ZH; Park H
MAGMA; 2012 Jun; 25(3):205-13. PubMed ID: 22071582
[TBL] [Abstract][Full Text] [Related]
20. Distortion correction in EPI at ultra-high-field MRI using PSF mapping with optimal combination of shift detection dimension.
Oh SH; Chung JY; In MH; Zaitsev M; Kim YB; Speck O; Cho ZH
Magn Reson Med; 2012 Oct; 68(4):1239-46. PubMed ID: 22213517
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]