173 related articles for article (PubMed ID: 26334036)
1. Influence of a micro-thread at cervical position and a cylindrical intermediate zone on the mechanical behaviour of dental implants: A three-dimensional finite element analysis.
Garitaonaindia U; Alcaraz JL
Proc Inst Mech Eng H; 2015 Sep; 229(9):670-80. PubMed ID: 26334036
[TBL] [Abstract][Full Text] [Related]
2. The dynamic natures of implant loading.
Wang RF; Kang B; Lang LA; Razzoog ME
J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
[TBL] [Abstract][Full Text] [Related]
3. The biomechanical analysis of simulating implants in function under osteoporotic jawbone by comparing cylindrical, apical tapered, neck tapered, and expandable type implants: a 3-dimensional finite element analysis.
Xiao JR; Li YF; Guan SM; Song L; Xu LX; Kong L
J Oral Maxillofac Surg; 2011 Jul; 69(7):e273-81. PubMed ID: 21367505
[TBL] [Abstract][Full Text] [Related]
4. Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method.
Bulaqi HA; Mousavi Mashhadi M; Geramipanah F; Safari H; Paknejad M
J Prosthet Dent; 2015 May; 113(5):405-11. PubMed ID: 25749081
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis.
Rasouli-Ghahroudi AA; Geramy A; Yaghobee S; Khorsand A; Yousefifakhr H; Rokn A; Soolari A
J Int Acad Periodontol; 2015 Jan; 17(1):2-13. PubMed ID: 26233968
[TBL] [Abstract][Full Text] [Related]
6. Comparison of implant body designs and threaded designs of dental implants: a 3-dimensional finite element analysis.
Huang HL; Chang CH; Hsu JT; Fallgatter AM; Ko CC
Int J Oral Maxillofac Implants; 2007; 22(4):551-62. PubMed ID: 17929515
[TBL] [Abstract][Full Text] [Related]
7. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants.
Çaglar A; Bal BT; Karakoca S; Aydın C; Yılmaz H; Sarısoy S
Int J Oral Maxillofac Implants; 2011; 26(5):961-9. PubMed ID: 22010077
[TBL] [Abstract][Full Text] [Related]
8. Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models.
Yamanishi Y; Yamaguchi S; Imazato S; Nakano T; Yatani H
J Periodontol; 2014 Sep; 85(9):e333-8. PubMed ID: 24835549
[TBL] [Abstract][Full Text] [Related]
9. The effect of implant thread design on stress distribution in anisotropic bone with different osseointegration conditions: a finite element analysis.
Mosavar A; Ziaei A; Kadkhodaei M
Int J Oral Maxillofac Implants; 2015; 30(6):1317-26. PubMed ID: 26478976
[TBL] [Abstract][Full Text] [Related]
10. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.
Kong L; Hu K; Li D; Song Y; Yang J; Wu Z; Liu B
Int J Oral Maxillofac Implants; 2008; 23(1):65-74. PubMed ID: 18416414
[TBL] [Abstract][Full Text] [Related]
12. The effect of implant design on the stress distribution in a three-unit implant-supported distal cantilever fixed partial denture: a three-dimensional finite-element analysis.
Koka P; Mohapatra A; Anandapandian PA; Murugesan K; Vasanthakumar M
Indian J Dent Res; 2012; 23(2):129-34. PubMed ID: 22945697
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
Merıç G; Erkmen E; Kurt A; Eser A; özden AU
Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: a nonlinear finite element analysis.
Silva GC; Cornacchia TM; de Magalhães CS; Bueno AC; Moreira AN
J Prosthet Dent; 2014 Dec; 112(6):1479-88. PubMed ID: 25062583
[TBL] [Abstract][Full Text] [Related]
15. Influence of lubricant on screw preload and stresses in a finite element model for a dental implant.
Jörn D; Kohorst P; Besdo S; Rücker M; Stiesch M; Borchers L
J Prosthet Dent; 2014 Aug; 112(2):340-8. PubMed ID: 24529658
[TBL] [Abstract][Full Text] [Related]
16. The effect of platform switching on stress distribution in implants and periimplant bone studied by nonlinear finite element analysis.
Liu S; Tang C; Yu J; Dai W; Bao Y; Hu D
J Prosthet Dent; 2014 Nov; 112(5):1111-8. PubMed ID: 24882594
[TBL] [Abstract][Full Text] [Related]
17. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: three-dimensional finite element method with statistical analysis.
de Faria Almeida DA; Pellizzer EP; Verri FR; Santiago JF; de Carvalho PS
J Periodontol; 2014 Feb; 85(2):261-9. PubMed ID: 23688104
[TBL] [Abstract][Full Text] [Related]
18. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
[TBL] [Abstract][Full Text] [Related]
19. Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysis.
Ao J; Li T; Liu Y; Ding Y; Wu G; Hu K; Kong L
Comput Biol Med; 2010 Aug; 40(8):681-6. PubMed ID: 20599193
[TBL] [Abstract][Full Text] [Related]
20. Analyzing the effects of the platform-switching procedure on stresses in the bone and implant-abutment complex by 3-dimensional fem analysis.
Cimen H; Yengin E
J Oral Implantol; 2012 Feb; 38(1):21-6. PubMed ID: 20662671
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]