BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 26337502)

  • 1. Nano-rheology of hydrogels using direct drive force modulation atomic force microscopy.
    Nalam PC; Gosvami NN; Caporizzo MA; Composto RJ; Carpick RW
    Soft Matter; 2015 Nov; 11(41):8165-78. PubMed ID: 26337502
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Robust strategies for automated AFM force curve analysis-II: adhesion-influenced indentation of soft, elastic materials.
    Lin DC; Dimitriadis EK; Horkay F
    J Biomech Eng; 2007 Dec; 129(6):904-12. PubMed ID: 18067395
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Molecular interactions and forces of adhesion between single human neural stem cells and gelatin methacrylate hydrogels of varying stiffness.
    Puckert C; Tomaskovic-Crook E; Gambhir S; Wallace GG; Crook JM; Higgins MJ
    Acta Biomater; 2020 Apr; 106():156-169. PubMed ID: 32084598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Laser Speckle Rheology for evaluating the viscoelastic properties of hydrogel scaffolds.
    Hajjarian Z; Nia HT; Ahn S; Grodzinsky AJ; Jain RK; Nadkarni SK
    Sci Rep; 2016 Dec; 6():37949. PubMed ID: 27905494
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measuring the elastic modulus of soft biomaterials using nanoindentation.
    Xu D; Harvey T; Begiristain E; Domínguez C; Sánchez-Abella L; Browne M; Cook RB
    J Mech Behav Biomed Mater; 2022 Sep; 133():105329. PubMed ID: 35753160
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noncontact microrheology at acoustic frequencies using frequency-modulated atomic force microscopy.
    Gavara N; Chadwick RS
    Nat Methods; 2010 Aug; 7(8):650-4. PubMed ID: 20562866
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rheological stability of carbomer in hydroalcoholic gels: Influence of alcohol type.
    Kolman M; Smith C; Chakrabarty D; Amin S
    Int J Cosmet Sci; 2021 Dec; 43(6):748-763. PubMed ID: 34741768
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Local rheology of human neutrophils investigated using atomic force microscopy.
    Lee YJ; Patel D; Park S
    Int J Biol Sci; 2011 Jan; 7(1):102-11. PubMed ID: 21278920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of cantilever tip geometry and contact model on AFM elasticity measurement of cells.
    Kulkarni SG; Pérez-Domínguez S; Radmacher M
    J Mol Recognit; 2023 Jul; 36(7):e3018. PubMed ID: 37025035
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nano-mechanical exploration of the surface and sub-surface of hydrated cells of Staphylococcus epidermidis.
    Méndez-Vilas A; Gallardo-Moreno AM; González-Martín ML
    Antonie Van Leeuwenhoek; 2006; 89(3-4):373-86. PubMed ID: 16779634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of elastic moduli of thin layers of soft material using the atomic force microscope.
    Dimitriadis EK; Horkay F; Maresca J; Kachar B; Chadwick RS
    Biophys J; 2002 May; 82(5):2798-810. PubMed ID: 11964265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tuning the Range of Polyacrylamide Gel Stiffness for Mechanobiology Applications.
    Denisin AK; Pruitt BL
    ACS Appl Mater Interfaces; 2016 Aug; 8(34):21893-902. PubMed ID: 26816386
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spatially resolved frequency-dependent elasticity measured with pulsed force microscopy and nanoindentation.
    Sweers KK; van der Werf KO; Bennink ML; Subramaniam V
    Nanoscale; 2012 Mar; 4(6):2072-7. PubMed ID: 22331128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigation of micromechanical properties of hard sphere filled composite hydrogels by atomic force microscopy and finite element simulations.
    Tang G; Galluzzi M; Biswas CS; Stadler FJ
    J Mech Behav Biomed Mater; 2018 Feb; 78():496-504. PubMed ID: 29248847
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Model-Free Rheo-AFM Probes the Viscoelasticity of Tunable DNA Soft Colloids.
    Moreno-Guerra JA; Romero-Sánchez IC; Martinez-Borquez A; Tassieri M; Stiakakis E; Laurati M
    Small; 2019 Oct; 15(42):e1904136. PubMed ID: 31460707
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Indenting soft samples (hydrogels and cells) with cantilevers possessing various shapes of probing tip.
    Zemła J; Bobrowska J; Kubiak A; Zieliński T; Pabijan J; Pogoda K; Bobrowski P; Lekka M
    Eur Biophys J; 2020 Sep; 49(6):485-495. PubMed ID: 32803311
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of work of adhesion of biological cell under AFM bead indentation.
    Zhu X; Siamantouras E; Liu KK; Liu X
    J Mech Behav Biomed Mater; 2016 Mar; 56():77-86. PubMed ID: 26688423
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Validation Study of the Repeatability and Accuracy of Atomic Force Microscopy Indentation Using Polyacrylamide Gels and Colloidal Probes.
    Lee D; Ryu S
    J Biomech Eng; 2017 Apr; 139(4):. PubMed ID: 28005134
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Laser cavitation rheology for measurement of elastic moduli and failure strain within hydrogels.
    Luo JC; Ching H; Wilson BG; Mohraz A; Botvinick EL; Venugopalan V
    Sci Rep; 2020 Aug; 10(1):13144. PubMed ID: 32753667
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nanomechanical measurements of polyethylene glycol hydrogels using atomic force microscopy.
    Drira Z; Yadavalli VK
    J Mech Behav Biomed Mater; 2013 Feb; 18():20-8. PubMed ID: 23237877
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.