239 related articles for article (PubMed ID: 26338293)
21. Multicenter evaluation of a real-time loop-mediated isothermal amplification (RealAmp) test for rapid diagnosis of Mycobacterium tuberculosis.
Ou X; Wang S; Dong H; Pang Y; Li Q; Xia H; Qu Y; Zhang Z; Li J; Zhang J; Huan S; Chin DP; Zhao Y
J Microbiol Methods; 2016 Oct; 129():39-43. PubMed ID: 27425377
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of real-time loop-mediated isothermal amplification (RealAmp) for rapid detection of Mycobacterium tuberculosis from sputum samples.
Li Y; Shi L; Pan A; Cao W; Chen X; Meng H; Yan H; Miyoshi S; Ye L
J Microbiol Methods; 2014 Sep; 104():55-8. PubMed ID: 24968954
[TBL] [Abstract][Full Text] [Related]
23. Evaluation of Loopamp™MTBC detection kit for diagnosis of pulmonary tuberculosis at a peripheral laboratory in a high burden setting.
Nguyen VAT; Nguyen HV; Dinh TV; Du HH; Do CN; Marks GB; Nguyen NV
Diagn Microbiol Infect Dis; 2018 Mar; 90(3):190-195. PubMed ID: 29246776
[TBL] [Abstract][Full Text] [Related]
24. Comparison of the efficacies of loop-mediated isothermal amplification, fluorescence smear microscopy and culture for the diagnosis of tuberculosis.
George G; Mony P; Kenneth J
PLoS One; 2011; 6(6):e21007. PubMed ID: 21695047
[TBL] [Abstract][Full Text] [Related]
25. Diagnostic yield of Bronchoalveolar Lavage gene Xpert in smear-negative and sputum-scarce pulmonary tuberculosis.
Khalil KF; Butt T
J Coll Physicians Surg Pak; 2015 Feb; 25(2):115-8. PubMed ID: 25703755
[TBL] [Abstract][Full Text] [Related]
26. Comparative Evaluation of the Loop-Mediated Isothermal Amplification Assay for Detecting Pulmonary Tuberculosis.
Kim CK; Cho EA; Shin DM; Choi SW; Shin SY
Ann Lab Med; 2018 Mar; 38(2):119-124. PubMed ID: 29214755
[TBL] [Abstract][Full Text] [Related]
27. Pragmatic accuracy of an in-house loop-mediated isothermal amplification (LAMP) for diagnosis of pulmonary tuberculosis in a Thai community hospital.
Toonkomdang S; Phinyo P; Phetsuksiri B; Patumanond J; Rudeeaneksin J; Klayut W
PLoS One; 2020; 15(7):e0236496. PubMed ID: 32702008
[TBL] [Abstract][Full Text] [Related]
28. Clinical diagnostic performance of the simultaneous amplification and testing methods for detection of the Mycobacterium tuberculosis complex for smear-negative or sputum-scarce pulmonary tuberculosis in China.
Fan L; Zhang Q; Cheng L; Liu Z; Ji X; Cui Z; Ju J; Xiao H
Chin Med J (Engl); 2014; 127(10):1863-7. PubMed ID: 24824246
[TBL] [Abstract][Full Text] [Related]
29. A Large Cohort Study on the Clinical Value of Simultaneous Amplification and Testing for the Diagnosis of Pulmonary Tuberculosis.
Yan L; Tang S; Yang Y; Shi X; Ge Y; Sun W; Liu Y; Hao X; Gui X; Yin H; He Y; Zhang Q
Medicine (Baltimore); 2016 Jan; 95(4):e2597. PubMed ID: 26825909
[TBL] [Abstract][Full Text] [Related]
30. Evaluation of the TB-LAMP assay for the rapid diagnosis of pulmonary tuberculosis in Northern India.
Yadav R; Sharma N; Khaneja R; Agarwal P; Kanga A; Behera D; Sethi S
Int J Tuberc Lung Dis; 2017 Oct; 21(10):1150-1153. PubMed ID: 28911360
[TBL] [Abstract][Full Text] [Related]
31. Evaluation of the diagnostic value of loop-mediated isothermal amplification assays targeting three different Mycobacterium tuberculosis genes.
Guo YL; Wang SS; Jiang GL; Ban WJ; Liu Y
J Microbiol Methods; 2022 Sep; 200():106547. PubMed ID: 35926680
[TBL] [Abstract][Full Text] [Related]
32. Evaluation of reverse transcription loop-mediated isothermal amplification in conjunction with ELISA-hybridization assay for molecular detection of Mycobacterium tuberculosis.
Lee MF; Chen YH; Peng CF
J Microbiol Methods; 2009 Feb; 76(2):174-80. PubMed ID: 19022304
[TBL] [Abstract][Full Text] [Related]
33. [STUDY OF DIRECT TB-LAMP USING NON-CENTRIFUGAL SPUTUMS ABOUT EFFICIENCY FOR RAPID DIAGNOSIS OF TUBERCULOSIS].
Yoshida H; Onohara K; Tazawa T; Kawahara K; Tsurinaga Y; Han Y; Tamura Y; Nagai T; Hashimoto S; Kawase I
Kekkaku; 2015 May; 90(5):497-502. PubMed ID: 26489153
[TBL] [Abstract][Full Text] [Related]
34. Evaluation of Loopamp Assay for the Diagnosis of Pulmonary Tuberculosis in Cambodia.
Cheng S; Pheng SH; Heng S; Marks GB; Bañuls AL; Mao TE; Kerléguer A
Biomed Res Int; 2020; 2020():6828043. PubMed ID: 32596349
[TBL] [Abstract][Full Text] [Related]
35. A multicenter study of cross-priming amplification for tuberculosis diagnosis at peripheral level in China.
Ou X; Song Y; Zhao B; Li Q; Xia H; Zhou Y; Pang Y; Wang S; Zhang Z; Cheng S; Liu C; Zhao Y
Tuberculosis (Edinb); 2014 Jul; 94(4):428-33. PubMed ID: 24880705
[TBL] [Abstract][Full Text] [Related]
36. Comparison of Diagnostic Yield of Tuberculosis Loop-Mediated Isothermal Amplification Assay With Cartridge-Based Nucleic Acid Amplification Test, Acid-Fast Bacilli Microscopy, and Mycobacteria Growth Indicator Tube Culture in Children With Pulmonary Tuberculosis.
Dayal R; Yadav A; Agarwal D; Kumar M; Kamal R; Singh D; Bhatnagar S
J Pediatric Infect Dis Soc; 2021 Mar; 10(2):83-87. PubMed ID: 32154870
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of improved IS6110 LAMP assay for diagnosis of pulmonary and extra pulmonary tuberculosis.
Joon D; Nimesh M; Varma-Basil M; Saluja D
J Microbiol Methods; 2017 Aug; 139():87-91. PubMed ID: 28514671
[TBL] [Abstract][Full Text] [Related]
38. Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M. avium, and M. intracellulare in sputum samples.
Iwamoto T; Sonobe T; Hayashi K
J Clin Microbiol; 2003 Jun; 41(6):2616-22. PubMed ID: 12791888
[TBL] [Abstract][Full Text] [Related]
39. [Evaluation of the isothermal RNA amplification assay for Mycobacterium tuberculosis in sputum samples].
Cui ZL; Sha W; Huang XC; Zheng RJ; Ju JL; Hu ZY
Zhonghua Jie He He Hu Xi Za Zhi; 2011 Dec; 34(12):894-7. PubMed ID: 22333500
[TBL] [Abstract][Full Text] [Related]
40. Feasibility and Performance of Loop-Mediated Isothermal Amplification Assay in the Diagnosis of Pulmonary Tuberculosis in Decentralized Settings in Eastern China.
Wang Z; Sun H; Ren Z; Xue B; Lu J; Zhang H
Biomed Res Int; 2019; 2019():6845756. PubMed ID: 30805368
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]