These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 26341003)

  • 1. Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference.
    Ochs BG; Stuby FM; Stoeckle U; Gonser CE
    BMC Musculoskelet Disord; 2015 Sep; 16():240. PubMed ID: 26341003
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retrograde lag screw placement in anterior acetabular column with regard to the anterior pelvic plane and midsagittal plane -- virtual mapping of 260 three-dimensional hemipelvises for quantitative anatomic analysis.
    Ochs BG; Stuby FM; Ateschrang A; Stoeckle U; Gonser CE
    Injury; 2014 Oct; 45(10):1590-8. PubMed ID: 25062600
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The placement of percutaneous retrograde acetabular posterior column screw based on imaging anatomical study of acetabular posterior column corridor.
    Yu K; Zhou R; Gao S; Liang A; Yang M; Yang H
    J Orthop Surg Res; 2022 Nov; 17(1):492. PubMed ID: 36384572
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion.
    Puchwein P; Enninghorst N; Sisak K; Ortner T; Schildhauer TA; Balogh ZJ; Pichler W
    Arch Orthop Trauma Surg; 2012 Jun; 132(6):805-11. PubMed ID: 22358222
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Differences of percutaneous retrograde screw fixation of anterior column acetabular fractures between male and female: a study of 164 virtual three-dimensional models.
    Chen KN; Wang G; Cao LG; Zhang MC
    Injury; 2009 Oct; 40(10):1067-72. PubMed ID: 19329113
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Digital study of the ideal position of lag screw internal fixation in the anterior column of the acetabulum].
    Bai Y; Liu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2021 Jun; 35(6):684-689. PubMed ID: 34142493
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study.
    Dienstknecht T; Müller M; Sellei R; Nerlich M; Müller FJ; Fuechtmeier B; Berner A
    Int Orthop; 2013 Apr; 37(4):673-9. PubMed ID: 23250351
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of anterograde versus retrograde percutaneous screw fixation of anterior column acetabular fractures.
    Peng Y; Zhang L; Min W; Tang P
    Int J Comput Assist Radiol Surg; 2016 Apr; 11(4):635-9. PubMed ID: 26476636
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A quantitative anatomic study of plate-screw fixation of the acetabular anterior column through an anterior approach.
    Xian-quan W; Jin-fang C; Xue-cheng C; Wei-dong M; Wei Z; Shui S; Jin-lu Z; Jian W; Wei L
    Arch Orthop Trauma Surg; 2010 Feb; 130(2):257-62. PubMed ID: 19727782
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Minimal Invasive Fixation of Pelvic Injury: CT-Study of the Pelvic Bone Dimensions].
    Džupa V; Němec J; Pavlíčko Z; Laboš M; Šrám J; Taller S; Báča V
    Acta Chir Orthop Traumatol Cech; 2016; 83(3):147-54. PubMed ID: 27484071
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Implantation of iliosacral screws. Simulation of optimal placement by 3-dimensional X-ray computed tomography].
    Tonetti J; Cloppet O; Clerc M; Pittet L; Troccaz J; Merloz P; Chirossel J
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Jun; 86(4):360-9. PubMed ID: 10880935
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Anatomy study on the fixation technique of buttress plate in the posterior column of the acetabulum].
    Lü HR; He ZY; Wang GC; He JC
    Zhongguo Gu Shang; 2014 Apr; 27(4):321-5. PubMed ID: 25029842
    [TBL] [Abstract][Full Text] [Related]  

  • 13. CT-based 3-D visualisation of secure bone corridors and optimal trajectories for sacroiliac screws.
    Mendel T; Radetzki F; Wohlrab D; Stock K; Hofmann GO; Noser H
    Injury; 2013 Jul; 44(7):957-63. PubMed ID: 23246561
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Obturator Oblique and Pubic Ramus Inlet Views Can Better Guide the Insertion of an Anterior Column Acetabular Screw.
    Wang X; Ran G; Chen X; Jia H; Liu Z; Sun C; Ma L; Hou Z
    Orthop Surg; 2021 May; 13(3):1086-1093. PubMed ID: 33821566
    [TBL] [Abstract][Full Text] [Related]  

  • 15. CT-scan based anatomical study as a guidance for infra-acetabular screw placement.
    Lu Q; Zhou R; Gao S; Liang A; Yang M; Yang H
    BMC Musculoskelet Disord; 2021 Jun; 22(1):576. PubMed ID: 34167496
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The study of plate-screw fixation in the posterior wall of acetabulum using computed tomography images.
    Wu X; Chen W; Zhang Q; Su Y; Guo M; Qin D; Wang L; Zhang Y
    J Trauma; 2010 Aug; 69(2):423-31. PubMed ID: 20699753
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Single cannulated screws for stabilisation of pelvic ring and acetabular fractures].
    Taller S; Lukáš R; Srám J
    Acta Chir Orthop Traumatol Cech; 2011; 78(6):568-77. PubMed ID: 22217412
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Measurement of the maximum corridor parameters of infra acetabular screw and evaluation of the feasibility of screw insertion by digital analysis].
    Ma NF; Yang M; Tao ZS; Li TL
    Zhongguo Gu Shang; 2021 Mar; 34(3):220-5. PubMed ID: 33787164
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thoracic pedicle screws: comparison of start points and trajectories.
    Dhawan A; Klemme WR; Polly DW
    Spine (Phila Pa 1976); 2008 Nov; 33(24):2675-81. PubMed ID: 19011548
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computer-assisted surgery and intraoperative three-dimensional imaging for screw placement in different pelvic regions.
    Grossterlinden L; Nuechtern J; Begemann PG; Fuhrhop I; Petersen JP; Ruecker A; Rupprecht M; Lehmann W; Schumacher U; Rueger JM; Briem D
    J Trauma; 2011 Oct; 71(4):926-32. PubMed ID: 21610540
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.