These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 26345848)

  • 1. Macrophage proinflammatory response to the titanium alloy equipment in dental implantation.
    Chen X; Li HS; Yin Y; Feng Y; Tan XW
    Genet Mol Res; 2015 Aug; 14(3):9155-62. PubMed ID: 26345848
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [An experimental study on the cytokine expression of macrophage influenced by biomaterials].
    Li G; Yang P; Wang J; Zhao A; Huang N
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Feb; 26(1):105-9. PubMed ID: 19334566
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of titanium surface topography on macrophage activation and secretion of proinflammatory cytokines and chemokines.
    Refai AK; Textor M; Brunette DM; Waterfield JD
    J Biomed Mater Res A; 2004 Aug; 70(2):194-205. PubMed ID: 15227664
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro effects of macrophages on orthopaedic implant alloys and local release of metallic alloy components.
    Heise G; Black CM; Smith R; Morrow BR; Mihalko WM
    Bone Joint J; 2020 Jul; 102-B(7_Supple_B):116-121. PubMed ID: 32600200
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mesenteric adipose tissue-derived monocyte chemoattractant protein-1 plays a crucial role in adipose tissue macrophage migration and activation in obese mice.
    Yu R; Kim CS; Kwon BS; Kawada T
    Obesity (Silver Spring); 2006 Aug; 14(8):1353-62. PubMed ID: 16988077
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dental implant surface chemistry and energy alter macrophage activation in vitro.
    Hotchkiss KM; Ayad NB; Hyzy SL; Boyan BD; Olivares-Navarrete R
    Clin Oral Implants Res; 2017 Apr; 28(4):414-423. PubMed ID: 27006244
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of titanium surface topography on J774A.1 macrophage inflammatory cytokines and nitric oxide production.
    Tan KS; Qian L; Rosado R; Flood PM; Cooper LF
    Biomaterials; 2006 Oct; 27(30):5170-7. PubMed ID: 16808973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of hydrophilic titanium surface modification on macrophage inflammatory cytokine gene expression.
    Hamlet S; Alfarsi M; George R; Ivanovski S
    Clin Oral Implants Res; 2012 May; 23(5):584-90. PubMed ID: 22093029
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of scaling titanium implant surfaces with metal and plastic instruments on cell attachment.
    Dmytryk JJ; Fox SC; Moriarty JD
    J Periodontol; 1990 Aug; 61(8):491-6. PubMed ID: 2202808
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
    Serhan H; Slivka M; Albert T; Kwak SD
    Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages.
    Dalal A; Pawar V; McAllister K; Weaver C; Hallab NJ
    J Biomed Mater Res A; 2012 Aug; 100(8):2147-58. PubMed ID: 22615169
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Titanium surface topography alters cell shape and modulates bone morphogenetic protein 2 expression in the J774A.1 macrophage cell line.
    Takebe J; Champagne CM; Offenbacher S; Ishibashi K; Cooper LF
    J Biomed Mater Res A; 2003 Feb; 64(2):207-16. PubMed ID: 12522806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative neuromonitoring: can the results of direct stimulation of titanium-alloy pedicle screws in the thoracic spine be trusted?
    Donohue ML; Swaminathan V; Gilbert JL; Fox CW; Smale J; Moquin RR; Calancie B
    J Clin Neurophysiol; 2012 Dec; 29(6):502-8. PubMed ID: 23207589
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Macrophage responses to 316L stainless steel and cobalt chromium alloys with different surface topographies.
    Anderson JA; Lamichhane S; Mani G
    J Biomed Mater Res A; 2016 Nov; 104(11):2658-72. PubMed ID: 27324956
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reduced inflammatory activity of RAW 264.7 macrophages on titania nanotube modified Ti surface.
    Neacsu P; Mazare A; Cimpean A; Park J; Costache M; Schmuki P; Demetrescu I
    Int J Biochem Cell Biol; 2014 Oct; 55():187-95. PubMed ID: 25220343
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison between 4.0-mm stainless steel and 4.75-mm titanium alloy single-rod spinal instrumentation for anterior thoracoscopic scoliosis surgery.
    Yoon SH; Ugrinow VL; Upasani VV; Pawelek JB; Newton PO
    Spine (Phila Pa 1976); 2008 Sep; 33(20):2173-8. PubMed ID: 18794758
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires.
    Verstrynge A; Van Humbeeck J; Willems G
    Am J Orthod Dentofacial Orthop; 2006 Oct; 130(4):460-70. PubMed ID: 17045145
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early inflammatory response in soft tissues induced by thin calcium phosphates.
    Rydén L; Molnar D; Esposito M; Johansson A; Suska F; Palmquist A; Thomsen P
    J Biomed Mater Res A; 2013 Sep; 101(9):2712-7. PubMed ID: 23463679
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rabies virus stimulates nitric oxide production and CXC chemokine ligand 10 expression in macrophages through activation of extracellular signal-regulated kinases 1 and 2.
    Nakamichi K; Inoue S; Takasaki T; Morimoto K; Kurane I
    J Virol; 2004 Sep; 78(17):9376-88. PubMed ID: 15308732
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.