BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 26348406)

  • 1. Realization of fluence field modulated CT on a clinical TomoTherapy megavoltage CT system.
    Szczykutowicz TP; Hermus J; Geurts M; Smilowitz J
    Phys Med Biol; 2015 Sep; 60(18):7245-57. PubMed ID: 26348406
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental realization of fluence field modulated CT using digital beam attenuation.
    Szczykutowicz TP; Mistretta CA
    Phys Med Biol; 2014 Mar; 59(5):1305-26. PubMed ID: 24556823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Volume-of-interest (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose.
    Kolditz D; Kyriakou Y; Kalender WA
    Med Phys; 2010 Jun; 37(6):2719-30. PubMed ID: 20632582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Volume-of-interest cone-beam CT using a 2.35 MV beam generated with a carbon target.
    Robar JL; Parsons D; Berman A; Macdonald A
    Med Phys; 2012 Jul; 39(7):4209-18. PubMed ID: 22830754
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Creation of an atlas of filter positions for fluence field modulated CT.
    Szczykutowicz TP; Hermus J
    Med Phys; 2015 Apr; 42(4):1779-86. PubMed ID: 25832068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fluence field optimization for noise and dose objectives in CT.
    Bartolac S; Graham S; Siewerdsen J; Jaffray D
    Med Phys; 2011 Jul; 38 Suppl 1():S2. PubMed ID: 21978114
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation doses in volume-of-interest breast computed tomography--A Monte Carlo simulation study.
    Lai CJ; Zhong Y; Yi Y; Wang T; Shaw CC
    Med Phys; 2015 Jun; 42(6):3063-75. PubMed ID: 26127058
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Compensator models for fluence field modulated computed tomography.
    Bartolac S; Jaffray D
    Med Phys; 2013 Dec; 40(12):121909. PubMed ID: 24320520
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.
    Szczykutowicz TP; Mistretta CA
    Med Phys; 2013 Feb; 40(2):021906. PubMed ID: 23387754
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An optimization algorithm for dose reduction with fluence-modulated proton CT.
    Dickmann J; Rit S; Pankuch M; Johnson RP; Schulte RW; Parodi K; Dedes G; Landry G
    Med Phys; 2020 Apr; 47(4):1895-1906. PubMed ID: 32040212
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of megavoltage computed tomographic scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy.
    Zhu J; Bai T; Gu J; Sun Z; Wei Y; Li B; Yin Y
    Radiat Oncol; 2018 Apr; 13(1):80. PubMed ID: 29699582
    [TBL] [Abstract][Full Text] [Related]  

  • 12. System for verifiable CT radiation dose optimization based on image quality. part I. Optimization model.
    Larson DB; Wang LL; Podberesky DJ; Goske MJ
    Radiology; 2013 Oct; 269(1):167-76. PubMed ID: 23784878
    [TBL] [Abstract][Full Text] [Related]  

  • 13. SU-F-BRCD-07: Experimental Validation of Fluence Field Modulation for Noise and Dose Management in CT.
    Bartolac S; Jaffray D
    Med Phys; 2012 Jun; 39(6Part20):3857. PubMed ID: 28517545
    [TBL] [Abstract][Full Text] [Related]  

  • 14. CT perfusion of renal cell carcinoma: impact of volume coverage on quantitative analysis.
    Reiner CS; Goetti R; Eberli D; Klotz E; Boss A; Pfammatter T; Frauenfelder T; Moch H; Sulser T; Alkadhi H
    Invest Radiol; 2012 Jan; 47(1):33-40. PubMed ID: 21730874
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of fluence field modulation to proton computed tomography for proton therapy imaging.
    Dedes G; De Angelis L; Rit S; Hansen D; Belka C; Bashkirov V; Johnson RP; Coutrakon G; Schubert KE; Schulte RW; Parodi K; Landry G
    Phys Med Biol; 2017 Jul; 62(15):6026-6043. PubMed ID: 28582265
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy.
    Halg RA; Besserer J; Schneider U
    Med Phys; 2012 Dec; 39(12):7650-61. PubMed ID: 23231313
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning.
    Wu V; Podgorsak MB; Tran TA; Malhotra HK; Wang IZ
    Med Phys; 2011 Jul; 38(7):4451-63. PubMed ID: 21859046
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spatial resolution improvement and dose reduction potential for inner ear CT imaging using a z-axis deconvolution technique.
    McCollough CH; Leng S; Sunnegardh J; Vrieze TJ; Yu L; Lane J; Raupach R; Stierstorfer K; Flohr T
    Med Phys; 2013 Jun; 40(6):061904. PubMed ID: 23718595
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure.
    Stiller W; Schwarzwaelder CB; Sommer CM; Veloza S; Radeleff BA; Kauczor HU
    Eur J Radiol; 2012 Jul; 81(7):1405-12. PubMed ID: 21458939
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Imaging dose management using multi-resolution in CT-guided radiation therapy.
    Sheng K; Jeraj R; Shaw R; Mackie TR; Paliwal BR
    Phys Med Biol; 2005 Mar; 50(6):1205-19. PubMed ID: 15798317
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.