1. High output cardiac failure following formation of an axillo-iliac arteriovenous graft for haemodialysis.
Goh MA; Ali JM; Lagaac R; Barlow AD; Pettigrew GJ
J Vasc Access; 2016 Jan; 17(1):e7-9. PubMed ID: 26349891
[No Abstract] [Full Text] [Related]
2. High-output cardiac failure following insertion of right femoral artery to left femoral vein PTFE graft for haemodialysis: a case report.
Acharya S; Banerjee D; Fronek J; Fossati N; Chemla ES
Semin Dial; 2009; 22(4):462-4. PubMed ID: 19473318
[TBL] [Abstract][Full Text] [Related]
3. Right Ventricular Enlargement within Months of Arteriovenous Fistula Creation in 2 Hemodialysis Patients.
Ragupathi L; Johnson D; Marhefka GD
Tex Heart Inst J; 2016 Aug; 43(4):350-3. PubMed ID: 27547150
[TBL] [Abstract][Full Text] [Related]
4. Access flow reduction for cardiac failure.
Bourquelot P
J Vasc Access; 2016 Mar; 17 Suppl 1():S60-3. PubMed ID: 26951907
[TBL] [Abstract][Full Text] [Related]
5. Intraoperative Ultrasound Guidance for Banding of an Arteriovenous Fistula Causing High Cardiac Output Heart Failure.
Turner AD; Chen M; Dahl N; Scoutt L; Dardik A; Ochoa Chaar CI
Ann Vasc Surg; 2020 Jul; 66():665.e5-665.e8. PubMed ID: 31863947
[TBL] [Abstract][Full Text] [Related]
6. Outcomes of blood flow suppression methods of treating high flow access in hemodialysis patients with arteriovenous fistula.
Kanno T; Kamijo Y; Hashimoto K; Kanno Y
J Vasc Access; 2015 Nov; 16 Suppl 10():S28-33. PubMed ID: 26349882
[TBL] [Abstract][Full Text] [Related]
7. Axillary Artery to Right Atrial Graft for Dialysis Access Using an Autologous Femoropopliteal Vein.
Chauhan Y; Zubair MM; Inkollu S; Peden EK
Ann Vasc Surg; 2017 Nov; 45():262.e7-262.e10. PubMed ID: 28647632
[TBL] [Abstract][Full Text] [Related]
8. Minimally invasive axillary to right atrial graft for hemodialysis access utilizing the intraluminal flow guard graft.
Goldstein LJ; Balabanoff C; Carillo R; de Mendoza VL; Bornak A; Tabbara M
J Vasc Access; 2015 Sep; 16(5):e87-8. PubMed ID: 26349871
[No Abstract] [Full Text] [Related]
9. Arteriovenous graft with outflow in the proximal axillary vein.
Teruya TH; Schaeffer D; Abou-Zamzam AM; Bianchi C
Ann Vasc Surg; 2009; 23(1):95-8. PubMed ID: 18809289
[TBL] [Abstract][Full Text] [Related]
10. Rescue of an axillary-axillary arteriovenous graft not amenable to endovascular intervention by formation of an axillary loop: a case report.
Frampton AE; Hossain M; Hamidian Jahromi A; Morsy M; Chemla ES
J Vasc Access; 2009; 10(1):55-8. PubMed ID: 19340801
[TBL] [Abstract][Full Text] [Related]
11. Axillo-iliac conduit for haemodialysis vascular access.
Hamish M; Shalhoub J; Rodd CD; Davies AH
Eur J Vasc Endovasc Surg; 2006 May; 31(5):530-4. PubMed ID: 16427332
[TBL] [Abstract][Full Text] [Related]
12. Anterior chest wall arteriovenous graft for dialysis.
Otani M; Takeo M; Nakajima Y
J Vasc Access; 2013; 14(2):207. PubMed ID: 23180562
[No Abstract] [Full Text] [Related]
13. Arteriovenous Fistula Creation for End-Stage Renal Disease May Worsen Pulmonary Hypertension.
Babadjanov J; Miler R; Niebauer K; Kirksey L
Ann Vasc Surg; 2016 Oct; 36():293.e1-293.e3. PubMed ID: 27423711
[TBL] [Abstract][Full Text] [Related]
14. A case series of real-time hemodynamic assessment of high output heart failure as a complication of arteriovenous access in dialysis patients.
Singh S; Elramah M; Allana SS; Babcock M; Keevil JG; Johnson MR; Yevzlin AS; Chan MR
Semin Dial; 2014; 27(6):633-8. PubMed ID: 24673654
[TBL] [Abstract][Full Text] [Related]
15. VORTEC technique in central venous recanalization for haemodialysis access salvage.
Törnqvist P; Hedin U; Asciutto G; Engström J; Bountouris I; Kristmundsson T; Sterner G; Dias NV
J Vasc Access; 2016 Jan; 17(1):e3-4. PubMed ID: 26932600
[No Abstract] [Full Text] [Related]
16. Revision using distal inflow for treatment of heart failure secondary to arteriovenous fistula for hemodialysis.
Parmar CD; Chieng G; Abraham KA; Kumar S; Torella F
J Vasc Access; 2009; 10(1):62-3. PubMed ID: 19340803
[TBL] [Abstract][Full Text] [Related]
17. The surgical management of high-output cardiac failure due to arteriovenous haemodialysis fistulae.
Khalil I; Sfeir P
Eur J Vasc Surg; 1993 Sep; 7(5):577-9. PubMed ID: 8405505
[No Abstract] [Full Text] [Related]
18. Use of a temporary shunt to preserve the patency of a hemodialysis graft while performing ipsilateral axillo-femoral bypass.
Argyriou C; Schoretsanitis N; Kantartzi K; Panagoutsos S; Souftas VD; Lazarides MK; Georgiadis GS
J Vasc Access; 2019 Sep; 20(5):553-556. PubMed ID: 30618343
[TBL] [Abstract][Full Text] [Related]
19. Simultaneous Iliac Vein Bovine Pericardial Patch Venoplasty and Creation of PTFE Lower Limb Arteriovenous Fistula Graft for Rescue Vascular Access.
Meecham L; Fisher O; Kirby G; Evans R; Buxton P; Legge J; Rajagopalan S; Asquith J; Pherwani A
Ann Vasc Surg; 2016 Oct; 36():292.e9-292.e11. PubMed ID: 27423716
[TBL] [Abstract][Full Text] [Related]
20. Non-invasively assessed haemodynamics in patients with high flow arteriovenous fistula and high output cardiac failure.
Salajová KB; Malík J; Valeriánová A
ESC Heart Fail; 2024 Jun; 11(3):1808-1809. PubMed ID: 38577732
[No Abstract] [Full Text] [Related]
[Next] [New Search]