BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 26351941)

  • 1. Comparing the effect of isotopically labeled or structural analog internal standards on the performance of a LC-MS/MS method to determine ciclosporin A, everolimus, sirolimus and tacrolimus in whole blood.
    Valbuena H; Shipkova M; Kliesch SM; Müller S; Wieland E
    Clin Chem Lab Med; 2016 Mar; 54(3):437-46. PubMed ID: 26351941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An isotope dilution LC-MS/MS based candidate reference method for the quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human whole blood.
    Taibon J; van Rooij M; Schmid R; Singh N; Albrecht E; Anne Wright J; Geletneky C; Schuster C; Mörlein S; Vogeser M; Seger C; Pongratz S; Kobold U
    Clin Biochem; 2020 Aug; 82():73-84. PubMed ID: 31770523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of a stable isotope-labeled and an analog internal standard for the quantification of everolimus by a liquid chromatography-tandem mass spectrometry method.
    Heideloff C; Payto D; Wang S
    Ther Drug Monit; 2013 Apr; 35(2):246-50. PubMed ID: 23503452
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous quantification of cyclosporin, tacrolimus, sirolimus and everolimus in whole blood by UHPLC-MS/MS for therapeutic drug monitoring.
    Antunes NJ; Kipper K; Couchman L; Duncan MA; Holt DW; De Nucci G; Johnston A
    Biomed Chromatogr; 2021 Jun; 35(6):e5071. PubMed ID: 33462848
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of cyclosporine, tacrolimus, sirolimus and everolimus by liquid chromatography coupled to electrospray ionization and tandem mass spectrometry: assessment of matrix effects and assay performance.
    Vethe NT; Gjerdalen LC; Bergan S
    Scand J Clin Lab Invest; 2010 Dec; 70(8):583-91. PubMed ID: 21039189
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid determination of immunosuppressive drug concentrations in whole blood by coated blade spray-tandem mass spectrometry (CBS-MS/MS).
    Gómez-Ríos GA; Tascon M; Reyes-Garcés N; Boyacı E; Poole JJ; Pawliszyn J
    Anal Chim Acta; 2018 Jan; 999():69-75. PubMed ID: 29254576
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the MassTrak Immunosuppressant XE Kit for the determination of everolimus and cyclosporin A in human whole blood employing isotopically labeled internal standards.
    Ji M; Kim S; Chung HJ; Lee W; Chun S; Min WK
    Clin Chem Lab Med; 2011 Dec; 49(12):2021-7. PubMed ID: 21756161
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultra fast liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of cyclosporin A, tacrolimus, sirolimus, and everolimus in whole blood using deuterated internal standards for cyclosporin A and everolimus.
    Meinitzer A; Gartner G; Pilz S; Stettin M
    Ther Drug Monit; 2010 Feb; 32(1):61-6. PubMed ID: 20010460
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Robust, high-throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus, and sirolimus in whole blood.
    Koster RA; Dijkers EC; Uges DR
    Ther Drug Monit; 2009 Feb; 31(1):116-25. PubMed ID: 19065123
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a novel commercial assay for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus by liquid chromatography-tandem mass spectrometric assay.
    Becker S; Thiery J; Ceglarek U
    Ther Drug Monit; 2013 Feb; 35(1):129-32. PubMed ID: 23188181
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of cyclosporin A, tacrolimus, sirolimus, and everolimus in dried blood spot samples using liquid chromatography tandem mass spectrometry.
    den Burger JC; Wilhelm AJ; Chahbouni A; Vos RM; Sinjewel A; Swart EL
    Anal Bioanal Chem; 2012 Oct; 404(6-7):1803-11. PubMed ID: 22899246
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Salting Out-Assisted Liquid-Liquid Extraction for Liquid Chromatography-Tandem Mass Spectrometry Measurement of Tacrolimus, Sirolimus, Everolimus, and Cyclosporine a in Whole Blood.
    Kvamsøe MM; Hansen KR; Skadberg Ø; Vethe NT; Brede C
    Ther Drug Monit; 2020 Oct; 42(5):695-701. PubMed ID: 32701594
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous LC-MS-MS determination of cyclosporine A, tacrolimus, and sirolimus in whole blood as well as mycophenolic acid in plasma using common pretreatment procedure.
    Bogusz MJ; Enazi EA; Hassan H; Abdel-Jawaad J; Ruwaily JA; Tufail MA
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May; 850(1-2):471-80. PubMed ID: 17239667
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Two rapid ultra performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) methods with common sample pretreatment for therapeutic drug monitoring of immunosuppressants compared to immunoassay.
    Tszyrsznic W; Borowiec A; Pawlowska E; Jazwiec R; Zochowska D; Bartlomiejczyk I; Zegarska J; Paczek L; Dadlez M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jun; 928():9-15. PubMed ID: 23584041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast LC-MS/MS analysis of tacrolimus, sirolimus, everolimus and cyclosporin A in dried blood spots and the influence of the hematocrit and immunosuppressant concentration on recovery.
    Koster RA; Alffenaar JW; Greijdanus B; Uges DR
    Talanta; 2013 Oct; 115():47-54. PubMed ID: 24054560
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous determination of cyclosporine A, tacrolimus, sirolimus, and everolimus in whole-blood samples by LC-MS/MS.
    Karapirli M; Kizilgun M; Yesilyurt O; Gul H; Kunak ZI; Akgul EO; Macit E; Cayci T; Gulcan Kurt Y; Aydin I; Yaren H; Seyrek M; Cakir E; Yaman H
    ScientificWorldJournal; 2012; 2012():571201. PubMed ID: 22629148
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of four immunosuppressive drugs in whole blood using MEPS and LC-MS/MS allowing automated sample work-up and analysis.
    Said R; Pohanka A; Abdel-Rehim M; Beck O
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 May; 897():42-9. PubMed ID: 22542514
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative determination of four immunosuppressants by high resolution mass spectrometry (HRMS).
    Bruns K; Mönnikes R; Lackner KJ
    Clin Chem Lab Med; 2016 Jul; 54(7):1193-200. PubMed ID: 26641969
    [TBL] [Abstract][Full Text] [Related]  

  • 19. First UHPLC-MS/MS method coupled with automated online SPE for quantification both of tacrolimus and everolimus in peripheral blood mononuclear cells and its application on samples from co-treated pediatric patients.
    Pensi D; De Nicolò A; Pinon M; Pisciotta C; Calvo PL; Nonnato A; Romagnoli R; Tandoi F; Di Perri G; D'Avolio A
    J Mass Spectrom; 2017 Mar; 52(3):187-195. PubMed ID: 28098395
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous quantification of cyclosporine, tacrolimus, sirolimus and everolimus in whole blood by liquid chromatography-electrospray mass spectrometry.
    Ansermot N; Fathi M; Veuthey JL; Desmeules J; Rudaz S; Hochstrasser D
    Clin Biochem; 2008 Jun; 41(9):728-35. PubMed ID: 18358834
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.