206 related articles for article (PubMed ID: 26351941)
21. Simultaneous Determination of Everolimus, Sirolimus, Tacrolimus, and Cyclosporine-A by Mass Spectrometry.
Dinéia Perez J; Sanches Aragão D; Aparecida Ronchi F; Febba AC; Rosso CF; Tedesco-Silva Junior H; Medina de Abreu Pestana JO; Casarini DE
Transplant Proc; 2020 Jun; 52(5):1402-1408. PubMed ID: 32220480
[TBL] [Abstract][Full Text] [Related]
22. Simultaneous determination of cyclosporine, sirolimus, and tacrolimus in whole blood using liquid chromatography-tandem mass spectrometry.
Garg U; Munar A; Frazee CC
Methods Mol Biol; 2012; 902():167-73. PubMed ID: 22767117
[TBL] [Abstract][Full Text] [Related]
23. Evaluation of performance of new, isotopically labeled internal standard ([13c2d4]RAD001) for everolimus using a novel high-performance liquid chromatography tandem mass spectrometry method.
Korecka MA; Patel R; Shaw LM
Ther Drug Monit; 2011 Aug; 33(4):460-3. PubMed ID: 21743385
[TBL] [Abstract][Full Text] [Related]
24. Procedure for determination of immunosuppressive drugs in whole blood with liquid chromatography-isotope dilution mass spectrometry.
Molnár PM; Dux L; Reinauer H; Kress M; Akerboom T; Szederkényi E; Kaiser P
Clin Lab; 2011; 57(11-12):983-92. PubMed ID: 22239031
[TBL] [Abstract][Full Text] [Related]
25. Isotope-labeled versus analog internal standard in LC-MS/MS method for tacrolimus determination in human whole blood samples - A compensation of matrix effects.
Bodnar-Broniarczyk M; Pawiński T; Kunicki PK
J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Jan; 1104():220-227. PubMed ID: 30530114
[TBL] [Abstract][Full Text] [Related]
26. A high-throughput LC-MS/MS method for the quantification of four immunosu- ppressants drugs in whole blood.
Gong ZS; Wu ZH; Xu SX; Han WN; Jiang XM; Liu HP; Yan-Li ; Wei-Hu ; Yan-Wang
Clin Chim Acta; 2019 Nov; 498():21-26. PubMed ID: 31351928
[TBL] [Abstract][Full Text] [Related]
27. Sensitive quantification of sirolimus and everolimus by LC-MS/MS with online sample cleanup.
Mueller DM; Rentsch KM
J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Apr; 878(13-14):1007-12. PubMed ID: 20308022
[TBL] [Abstract][Full Text] [Related]
28. Use of a small particle solid-core packing for improved efficiency and rapid measurement of sirolimus and everolimus by LC-MS/MS.
Morgan P; Nwafor M; Tredger M
Biomed Chromatogr; 2016 Jun; 30(6):983-5. PubMed ID: 26419504
[TBL] [Abstract][Full Text] [Related]
29. Simultaneous measurement of cyclosporin A and tacrolimus from dried blood spots by ultra high performance liquid chromatography tandem mass spectrometry.
Hinchliffe E; Adaway JE; Keevil BG
J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():102-7. PubMed ID: 21680259
[TBL] [Abstract][Full Text] [Related]
30. Ultra-fast cyclosporin A quantitation in whole blood by Laser Diode Thermal Desorption-tandem mass spectrometry; comparison with High Performance Liquid Chromatography-tandem mass spectrometry.
Jourdil JF; Picard P; Meunier C; Auger S; Stanke-Labesque F
Anal Chim Acta; 2013 Dec; 805():80-6. PubMed ID: 24296146
[TBL] [Abstract][Full Text] [Related]
31. A direct method for the measurement of everolimus and sirolimus in whole blood by LC-MS/MS using an isotopic everolimus internal standard.
Morgan PE; Brown NW; Tredger JM
Ther Drug Monit; 2014 Jun; 36(3):358-65. PubMed ID: 24305629
[TBL] [Abstract][Full Text] [Related]
32. Validation of an LC-MS/MS method to determine five immunosuppressants with deuterated internal standards including MPA.
Buchwald A; Winkler K; Epting T
BMC Clin Pharmacol; 2012 Jan; 12():2. PubMed ID: 22236286
[TBL] [Abstract][Full Text] [Related]
33. High-throughput LC-MS/MS method for monitoring sirolimus and everolimus in the routine clinical laboratory.
Ivanova M; Artusi C; Polo G; Zaninotto M; Plebani M
Clin Chem Lab Med; 2011 Jul; 49(7):1151-8. PubMed ID: 21574883
[TBL] [Abstract][Full Text] [Related]
34. Clinical validation and implementation of a multiplexed immunosuppressant assay in dried blood spots by LC-MS/MS.
Sadilkova K; Busby B; Dickerson JA; Rutledge JC; Jack RM
Clin Chim Acta; 2013 Jun; 421():152-6. PubMed ID: 23473895
[TBL] [Abstract][Full Text] [Related]
35. Simultaneous determination of cyclosporine and tacrolimus in human whole blood by ultra-high performance liquid chromatography tandem mass spectrometry and comparison with a chemiluminescence microparticle immunoassay.
Mei S; Wang J; Chen D; Zhu L; Zhao M; Tian X; Hu X; Zhao Z
J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Jun; 1087-1088():36-42. PubMed ID: 29704799
[TBL] [Abstract][Full Text] [Related]
36. Dried blood spot validation of five immunosuppressants, without hematocrit correction, on two LC-MS/MS systems.
Koster RA; Veenhof H; Botma R; Hoekstra AT; Berger SP; Bakker SJ; Alffenaar JC; Touw DJ
Bioanalysis; 2017 Apr; 9(7):553-563. PubMed ID: 28300419
[TBL] [Abstract][Full Text] [Related]
37. A rapid and sensitive method to determine tacrolimus in rat whole blood using liquid-liquid extraction with mild temperature ultrasonication and LC-MS/MS.
Park JS; Cho HR; Kang MJ; Choi YS
Arch Pharm Res; 2016 Jan; 39(1):73-82. PubMed ID: 26589688
[TBL] [Abstract][Full Text] [Related]
38. Quantification of tacrolimus and three demethylated metabolites in human whole blood using LC-ESI-MS/MS.
Dubbelboer IR; Pohanka A; Said R; Rosenborg S; Beck O
Ther Drug Monit; 2012 Apr; 34(2):134-42. PubMed ID: 22406653
[TBL] [Abstract][Full Text] [Related]
39. Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography-mass spectrometry (LC-MS).
Deters M; Kirchner G; Resch K; Kaever V
Clin Chem Lab Med; 2002 Mar; 40(3):285-92. PubMed ID: 12005219
[TBL] [Abstract][Full Text] [Related]
40. Effective use of liquid chromatography-mass spectrometry (LC/MS) in the routine clinical laboratory for monitoring sirolimus, tacrolimus, and cyclosporine.
Poquette MA; Lensmeyer GL; Doran TC
Ther Drug Monit; 2005 Apr; 27(2):144-50. PubMed ID: 15795643
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]