These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

219 related articles for article (PubMed ID: 26371501)

  • 1. Radiation-force-based estimation of acoustic attenuation using harmonic motion imaging (HMI) in phantoms and in vitro livers before and after HIFU ablation.
    Chen J; Hou GY; Marquet F; Han Y; Camarena F; Konofagou E
    Phys Med Biol; 2015 Oct; 60(19):7499-512. PubMed ID: 26371501
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.
    Hou GY; Marquet F; Wang S; Konofagou EE
    Phys Med Biol; 2014 Mar; 59(5):1121-45. PubMed ID: 24556974
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU).
    Grondin J; Payen T; Wang S; Konofagou EE
    J Vis Exp; 2015 Nov; (105):e53050. PubMed ID: 26556647
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).
    Han Y; Hou GY; Wang S; Konofagou E
    Phys Med Biol; 2015 Aug; 60(15):5911-24. PubMed ID: 26184846
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-contact, ultrasound-based indentation method for measuring elastic properties of biological tissues using harmonic motion imaging (HMI).
    Vappou J; Hou GY; Marquet F; Shahmirzadi D; Grondin J; Konofagou EE
    Phys Med Biol; 2015 Apr; 60(7):2853-68. PubMed ID: 25776065
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of real-time acoustical and mechanical monitoring of high intensity focused ultrasound (HIFU) treatment using harmonic motion imaging for high focused ultrasound (HMIFU).
    Hou GY; Marquet F; Wang S; Konofagou EE
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6281-4. PubMed ID: 24111176
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance assessment of HIFU lesion detection by harmonic motion imaging for focused ultrasound (HMIFU): a 3-D finite-element-based framework with experimental validation.
    Hou GY; Luo J; Marquet F; Maleke C; Vappou J; Konofagou EE
    Ultrasound Med Biol; 2011 Dec; 37(12):2013-27. PubMed ID: 22036637
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantitative viscoelastic parameters measured by harmonic motion imaging.
    Vappou J; Maleke C; Konofagou EE
    Phys Med Biol; 2009 Jun; 54(11):3579-94. PubMed ID: 19454785
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Harmonic motion imaging for abdominal tumor detection and high-intensity focused ultrasound ablation monitoring: an in vivo feasibility study in a transgenic mouse model of pancreatic cancer.
    Chen H; Hou GY; Han Y; Payen T; Palermo CF; Olive KP; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Sep; 62(9):1662-73. PubMed ID: 26415128
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Technical Note: In vivo Young's modulus mapping of pancreatic ductal adenocarcinoma during HIFU ablation using harmonic motion elastography (HME).
    Nabavizadeh A; Payen T; Saharkhiz N; McGarry M; Olive KP; Konofagou EE
    Med Phys; 2018 Nov; 45(11):5244-5250. PubMed ID: 30178474
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast lesion mapping during HIFU treatment using harmonic motion imaging guided focused ultrasound (HMIgFUS) in vitro and in vivo.
    Han Y; Wang S; Payen T; Konofagou E
    Phys Med Biol; 2017 Apr; 62(8):3111-3123. PubMed ID: 28323638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Concurrent Visualization of Acoustic Radiation Force Displacement and Shear Wave Propagation with 7T MRI.
    Liu Y; Fite BZ; Mahakian LM; Johnson SM; Larrat B; Dumont E; Ferrara KW
    PLoS One; 2015; 10(10):e0139667. PubMed ID: 26439259
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterizing acoustic attenuation of homogeneous media using focused impulsive acoustic radiation force.
    Palmeri ML; Frinkley KD; Oldenburg KG; Nightingale KR
    Ultrason Imaging; 2006 Apr; 28(2):114-28. PubMed ID: 17094691
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Elasticity mapping of murine abdominal organs in vivo using harmonic motion imaging (HMI).
    Payen T; Palermo CF; Sastra SA; Chen H; Han Y; Olive KP; Konofagou EE
    Phys Med Biol; 2016 Aug; 61(15):5741-54. PubMed ID: 27401609
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Harmonic Motion Imaging-Guided Focused Ultrasound Ablation: Comparison of Three Focused Ultrasound Interference Filtering Methods.
    Li XJ; Hossain MM; Lee SA; Saharkhiz N; Konofagou E
    Ultrasound Med Biol; 2024 Jan; 50(1):119-127. PubMed ID: 37872031
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single-element focused ultrasound transducer method for harmonic motion imaging.
    Maleke C; Pernot M; Konofagou EE
    Ultrason Imaging; 2006 Jul; 28(3):144-58. PubMed ID: 17147056
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ex Vivo characterization of canine liver tissue viscoelasticity after high-intensity focused ultrasound ablation.
    Shahmirzadi D; Hou GY; Chen J; Konofagou EE
    Ultrasound Med Biol; 2014 Feb; 40(2):341-50. PubMed ID: 24315395
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simulation study of amplitude-modulated (AM) harmonic motion imaging (HMI) for stiffness contrast quantification with experimental validation.
    Maleke C; Luo J; Gamarnik V; Lu XL; Konofagou EE
    Ultrason Imaging; 2010 Jul; 32(3):154-76. PubMed ID: 20718245
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamic changes of integrated backscatter, attenuation coefficient and bubble activities during high-intensity focused ultrasound (HIFU) treatment.
    Zhang S; Wan M; Zhong H; Xu C; Liao Z; Liu H; Wang S
    Ultrasound Med Biol; 2009 Nov; 35(11):1828-44. PubMed ID: 19716225
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues.
    Maleke C; Konofagou EE
    Phys Med Biol; 2008 Mar; 53(6):1773-93. PubMed ID: 18367802
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.