423 related articles for article (PubMed ID: 26384584)
1. Urethral atrophy after implantation of an artificial urinary sphincter: fact or fiction?
Bugeja S; Ivaz SL; Frost A; Andrich DE; Mundy AR
BJU Int; 2016 Apr; 117(4):669-76. PubMed ID: 26384584
[TBL] [Abstract][Full Text] [Related]
2. Proof of concept: Exposing the myth of urethral atrophy after artificial urinary sphincter via assessment of circumferential recovery after capsulotomy and intraoperative pressure profiling of the pressure regulating balloon.
Pearlman AM; Rasper AM; Terlecki RP
Investig Clin Urol; 2018 Jul; 59(4):275-279. PubMed ID: 29984343
[TBL] [Abstract][Full Text] [Related]
3. Difference between urethral circumference and artificial urinary sphincter cuff size, and its effect on postoperative incontinence.
Rothschild J; Chang Kit L; Seltz L; Wang L; Kaufman M; Dmochowski R; Milam DF
J Urol; 2014 Jan; 191(1):138-42. PubMed ID: 23820053
[TBL] [Abstract][Full Text] [Related]
4. Causes of Artificial Urinary Sphincter Failure and Strategies for Surgical Revision: Implications of Device Component Survival.
Srivastava A; Joice GA; Patel HD; Manka MG; Sopko NA; Wright EJ
Eur Urol Focus; 2019 Sep; 5(5):887-893. PubMed ID: 29545058
[TBL] [Abstract][Full Text] [Related]
5. The Impact of Urethral Risk Factors on Transcorporeal Artificial Urinary Sphincter Erosion Rates and Device Survival.
Mock S; Dmochowski RR; Brown ET; Reynolds WS; Kaufman MR; Milam DF
J Urol; 2015 Dec; 194(6):1692-6. PubMed ID: 26141851
[TBL] [Abstract][Full Text] [Related]
6. Transcorporal artificial urinary sphincter cuff placement in cases requiring revision for erosion and urethral atrophy.
Guralnick ML; Miller E; Toh KL; Webster GD
J Urol; 2002 May; 167(5):2075-8; discussion 2079. PubMed ID: 11956443
[TBL] [Abstract][Full Text] [Related]
7. Artificial urinary sphincter revision for urethral atrophy: Comparing single cuff downsizing and tandem cuff placement.
Linder BJ; Viers BR; Ziegelmann MJ; Rivera ME; Elliott DS
Int Braz J Urol; 2017; 43(2):264-270. PubMed ID: 28128901
[TBL] [Abstract][Full Text] [Related]
8. Proximal artificial sphincter cuff repositioning for urethral atrophy incontinence.
Couillard DR; Vapnek JM; Stone AR
Urology; 1995 Apr; 45(4):653-6. PubMed ID: 7716847
[TBL] [Abstract][Full Text] [Related]
9. Urethral atrophy after artificial urinary sphincter placement: is cuff downsizing effective?
Saffarian A; Walsh K; Walsh IK; Stone AR
J Urol; 2003 Feb; 169(2):567-9. PubMed ID: 12544308
[TBL] [Abstract][Full Text] [Related]
10. Management of urethral atrophy after implantation of artificial urinary sphincter: what are the weaknesses?
Heah NH; Tan RBW
Asian J Androl; 2020; 22(1):60-63. PubMed ID: 31736473
[TBL] [Abstract][Full Text] [Related]
11. Artificial urinary sphincter revision: the role of ultrasound.
Brucker BM; Demirtas A; Fong E; Kelly C; Nitti VW
Urology; 2013 Dec; 82(6):1424-8. PubMed ID: 24295256
[TBL] [Abstract][Full Text] [Related]
12. Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy.
Zheng DC; Xie MK; Bao JW; Yao HJ; Wang Z
J Vis Exp; 2022 Jun; (184):. PubMed ID: 35781527
[TBL] [Abstract][Full Text] [Related]
13. Efficacy of Pressure Regulating Balloon Exchange in Men With Post Artificial Urinary Sphincter Persistent or Recurrent Stress Urinary Incontinence.
Moses RA; Keihani S; Craig JR; Basilius J; Hotaling JM; Lenherr SM; Brant WO; Myers JB
Urology; 2019 Jan; 123():252-257. PubMed ID: 30201300
[TBL] [Abstract][Full Text] [Related]
14. Outcomes following revisions and secondary implantation of the artificial urinary sphincter.
Raj GV; Peterson AC; Toh KL; Webster GD
J Urol; 2005 Apr; 173(4):1242-5. PubMed ID: 15758761
[TBL] [Abstract][Full Text] [Related]
15. [Application of modified urethral separation method in artificial urethral sphincter implantation and its influence on intraoperative urethral pressure profilometry].
Meng LF; Jing JB; Wang M; Liu XD; Hou HM; Zhou YH; Zhang Y; Wang J; Wang J; Wang L; Lyu YY; Wu JY; Zhang YG; Wang XM; Wang JW
Zhonghua Yi Xue Za Zhi; 2024 Feb; 104(6):427-432. PubMed ID: 38326054
[No Abstract] [Full Text] [Related]
16. Mechanical failure rates of artificial urinary sphincter components: Is the 3.5-cm urethral cuff at higher risk?
Loh-Doyle JC; Hartman N; Nazemi A; Wayne K; Doumanian LR; Ginsberg DA; Boyd SD
Neurourol Urodyn; 2019 Jan; 38(1):187-192. PubMed ID: 30248180
[TBL] [Abstract][Full Text] [Related]
17. Revision Techniques After Artificial Urinary Sphincter Failure in Men: Results From a Multicenter Study.
Eswara JR; Chan R; Vetter JM; Lai HH; Boone TB; Brandes SB
Urology; 2015 Jul; 86(1):176-80. PubMed ID: 26142602
[TBL] [Abstract][Full Text] [Related]
18. Is Risk of Artificial Urethral Sphincter Cuff Erosion Higher in Patients with Penile Prosthesis?
Sundaram V; Cordon BH; Hofer MD; Morey AF
J Sex Med; 2016 Sep; 13(9):1432-1437. PubMed ID: 27555513
[TBL] [Abstract][Full Text] [Related]
19. Combined external urethral bulking and artificial urinary sphincter for urethral atrophy and stress urinary incontinence.
Rahman NU; Minor TX; Deng D; Lue TF
BJU Int; 2005 Apr; 95(6):824-6. PubMed ID: 15794791
[TBL] [Abstract][Full Text] [Related]
20. Does nocturnal deactivation of the artificial urinary sphincter lessen the risk of urethral atrophy?
Elliott DS; Barrett DM; Gohma M; Boone TB
Urology; 2001 Jun; 57(6):1051-4. PubMed ID: 11377302
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]