These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 2638561)

  • 1. [Comparative determination of the lead concentration in the air in a working environment using x-ray fluorescence spectroscopy and the spectrophotometry method].
    Skrbić Z; Ribar B; Kiurski J; Janjić J
    Arh Hig Rada Toksikol; 1989 Sep; 40(3):285-90. PubMed ID: 2638561
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Determination of lead in workplace air by portable X-ray fluorescence spectrometry].
    Liu J; Liu Y; Chen Y; Zhao Y; Wang T
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2015 Apr; 33(4):299-301. PubMed ID: 26506785
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Determination of metal dusts in aerosols using x-ray fluorescence. Comparison with other analytical methods].
    Pozzoli L; Massola A; Angeleri S
    Ann Ist Super Sanita; 1978; 14(3):437-9. PubMed ID: 755394
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler.
    Harper M; Pacolay B; Hintz P; Andrew ME
    J Environ Monit; 2006 Mar; 8(3):384-92. PubMed ID: 16528423
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of X-ray fluorescence and wet chemical analysis of air filter samples from a scrap lead smelting operation.
    Harper M; Hallmark TS; Andrew ME; Bird AJ
    J Environ Monit; 2004 Oct; 6(10):819-26. PubMed ID: 15480496
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a portable X-ray fluorescence instrument for the determination of lead in workplace air samples.
    Morley JC; Clark CS; Deddens JA; Ashley K; Roda S
    Appl Occup Environ Hyg; 1999 May; 14(5):306-16. PubMed ID: 10446483
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Determination of metals in aerosol dust using X-ray fluorescence. Comparison with other analytical techniques].
    Pozzoli L; Massola A; Angeleri S
    Med Lav; 1978; 69(5):632-44. PubMed ID: 45747
    [No Abstract]   [Full Text] [Related]  

  • 8. A comparison of X-ray fluorescence and wet chemical analysis for lead on air filters from different personal samplers used in a bronze foundry.
    Harper M; Pacolay B; Andrew ME
    J Environ Monit; 2005 Jun; 7(6):592-7. PubMed ID: 15931420
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of X-ray fluorescence and wet chemical analysis for lead on air filters from different personal samplers used in a secondary lead smelter/solder manufacturer.
    Harper M; Pacolay B
    J Environ Monit; 2006 Jan; 8(1):140-6. PubMed ID: 16395471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Immediate screening of lead exposure in the workplace using portable X-ray fluorescence.
    Gorce JP; Roff M
    J Occup Environ Hyg; 2016; 13(2):102-11. PubMed ID: 26713915
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Portable XRF analysis of occupational air filter samples from different workplaces using different samplers: final results, summary and conclusions.
    Harper M; Pacolay B; Hintz P; Bartley DL; Slaven JE; Andrew ME
    J Environ Monit; 2007 Nov; 9(11):1263-70. PubMed ID: 17968454
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Uncertainty determination for nondestructive chemical analytical methods using field data and application to XRF analysis for lead.
    Bartley DL; Slaven JE; Rose MC; Andrew ME; Harper M
    J Occup Environ Hyg; 2007 Dec; 4(12):931-42. PubMed ID: 17957563
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of a field portable X-Ray fluorescence analyzer to determine the concentration of lead and other metals in soil samples.
    Clark S; Menrath W; Chen M; Roda S; Succop P
    Ann Agric Environ Med; 1999; 6(1):27-32. PubMed ID: 10384212
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Simultaneous determination of multiple elements in airborne particulate samples by X-ray fluorescence spectrometry].
    Takada T; Hitosugi M; Kadowaki T; Kudo M
    Sangyo Igaku; 1983 Jul; 25(4):235-44. PubMed ID: 6663820
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of manganese in airborne particulates in a dry-cell battery factory using X-ray fluorescence technique.
    Sumitra T; Kongsombatsuk S
    Biol Trace Elem Res; 1990; 26-27():269-77. PubMed ID: 1704728
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of the combustion method in a closed flask to the lead determination in atmospheric aerosols.
    Rauret G; Rubio R; Llauradó M
    Int J Environ Anal Chem; 1985; 23(1-2):59-68. PubMed ID: 4077373
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lead exposure during hot cutting of stripped steel.
    Brumis S; Scholz P; Materna B; Becker P
    Appl Occup Environ Hyg; 2001 May; 16(5):502-5. PubMed ID: 11370928
    [No Abstract]   [Full Text] [Related]  

  • 18. Lead exposures from varnished floor refinishing.
    Schirmer J; Havlena J; Jacobs DE; Dixon S; Ikens R
    J Occup Environ Hyg; 2012; 9(4):280-7. PubMed ID: 22494405
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples.
    Ashley K; Mapp KJ; Millson M
    Am Ind Hyg Assoc J; 1998 Oct; 59(10):671-9. PubMed ID: 9794065
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The determination of arsine in workplace air by x-ray fluorescence spectrometry.
    Keech DJ; West NG
    Ann Occup Hyg; 1980; 23(3):273-82. PubMed ID: 7447249
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.