366 related articles for article (PubMed ID: 26386140)
1. Real time monitoring of powder blend bulk density for coupled feed-forward/feed-back control of a continuous direct compaction tablet manufacturing process.
Singh R; Román-Ospino AD; Romañach RJ; Ierapetritou M; Ramachandran R
Int J Pharm; 2015 Nov; 495(1):612-625. PubMed ID: 26386140
[TBL] [Abstract][Full Text] [Related]
2. Development of near infrared spectroscopic calibration models for in-line determination of low drug concentration, bulk density, and relative specific void volume within a feed frame.
Ortega-Zúñiga C; la Rosa CP; Román-Ospino AD; Serrano-Vargas A; Romañach RJ; Méndez R
J Pharm Biomed Anal; 2019 Feb; 164():211-222. PubMed ID: 30391810
[TBL] [Abstract][Full Text] [Related]
3. Monitoring blend potency in a tablet press feed frame using near infrared spectroscopy.
Ward HW; Blackwood DO; Polizzi M; Clarke H
J Pharm Biomed Anal; 2013 Jun; 80():18-23. PubMed ID: 23511228
[TBL] [Abstract][Full Text] [Related]
4. System-wide hybrid MPC-PID control of a continuous pharmaceutical tablet manufacturing process via direct compaction.
Singh R; Ierapetritou M; Ramachandran R
Eur J Pharm Biopharm; 2013 Nov; 85(3 Pt B):1164-82. PubMed ID: 23523542
[TBL] [Abstract][Full Text] [Related]
5. Feed frame: The last processing step before the tablet compaction in pharmaceutical manufacturing.
Sierra-Vega NO; Romañach RJ; Méndez R
Int J Pharm; 2019 Dec; 572():118728. PubMed ID: 31682965
[TBL] [Abstract][Full Text] [Related]
6. Implementation of an advanced hybrid MPC-PID control system using PAT tools into a direct compaction continuous pharmaceutical tablet manufacturing pilot plant.
Singh R; Sahay A; Karry KM; Muzzio F; Ierapetritou M; Ramachandran R
Int J Pharm; 2014 Oct; 473(1-2):38-54. PubMed ID: 24974987
[TBL] [Abstract][Full Text] [Related]
7. Influence of raw material properties upon critical quality attributes of continuously produced granules and tablets.
Fonteyne M; Wickström H; Peeters E; Vercruysse J; Ehlers H; Peters BH; Remon JP; Vervaet C; Ketolainen J; Sandler N; Rantanen J; Naelapää K; De Beer T
Eur J Pharm Biopharm; 2014 Jul; 87(2):252-63. PubMed ID: 24589422
[TBL] [Abstract][Full Text] [Related]
8. Measuring the distribution of density and tabletting force in pharmaceutical tablets by chemical imaging.
Ellison CD; Ennis BJ; Hamad ML; Lyon RC
J Pharm Biomed Anal; 2008 Sep; 48(1):1-7. PubMed ID: 18539424
[TBL] [Abstract][Full Text] [Related]
9. Assessment of powder blend uniformity: Comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging.
Bakri B; Weimer M; Hauck G; Reich G
Eur J Pharm Biopharm; 2015 Nov; 97(Pt A):78-89. PubMed ID: 26455421
[TBL] [Abstract][Full Text] [Related]
10. In-line monitoring and optimization of powder flow in a simulated continuous process using transmission near infrared spectroscopy.
Alam MA; Shi Z; Drennen JK; Anderson CA
Int J Pharm; 2017 Jun; 526(1-2):199-208. PubMed ID: 28445765
[TBL] [Abstract][Full Text] [Related]
11. Near infrared spectroscopic calibration models for real time monitoring of powder density.
Román-Ospino AD; Singh R; Ierapetritou M; Ramachandran R; Méndez R; Ortega-Zuñiga C; Muzzio FJ; Romañach RJ
Int J Pharm; 2016 Oct; 512(1):61-74. PubMed ID: 27543356
[TBL] [Abstract][Full Text] [Related]
12. Multispectral UV imaging for fast and non-destructive quality control of chemical and physical tablet attributes.
Klukkert M; Wu JX; Rantanen J; Carstensen JM; Rades T; Leopold CS
Eur J Pharm Sci; 2016 Jul; 90():85-95. PubMed ID: 26657202
[TBL] [Abstract][Full Text] [Related]
13. Integrating sensors for monitoring blend content in a pharmaceutical continuous manufacturing plant.
Panikar S; Li J; Rane V; Gillam S; Callegari G; Kurtyka B; Lee S; Muzzio F
Int J Pharm; 2021 Sep; 606():120085. PubMed ID: 33737095
[TBL] [Abstract][Full Text] [Related]
14. Analysis of powder phenomena inside a Fette 3090 feed frame using in-line NIR spectroscopy.
Mateo-Ortiz D; Colon Y; Romañach RJ; Méndez R
J Pharm Biomed Anal; 2014 Nov; 100():40-49. PubMed ID: 25128874
[TBL] [Abstract][Full Text] [Related]
15. Real-time assessment of critical quality attributes of a continuous granulation process.
Fonteyne M; Vercruysse J; Díaz DC; Gildemyn D; Vervaet C; Remon JP; De Beer T
Pharm Dev Technol; 2013 Feb; 18(1):85-97. PubMed ID: 22023327
[TBL] [Abstract][Full Text] [Related]
16. Pharmaceutical excipients properties and screw feeder performance in continuous processing lines: a Quality by Design (QbD) approach.
Santos B; Carmo F; Schlindwein W; Muirhead G; Rodrigues C; Cabral L; Westrup J; Pitt K
Drug Dev Ind Pharm; 2018 Dec; 44(12):2089-2097. PubMed ID: 30113219
[TBL] [Abstract][Full Text] [Related]
17. Near-infrared chemical imaging (NIR-CI) as a process monitoring solution for a production line of roll compaction and tableting.
Khorasani M; Amigo JM; Sun CC; Bertelsen P; Rantanen J
Eur J Pharm Biopharm; 2015 Jun; 93():293-302. PubMed ID: 25917640
[TBL] [Abstract][Full Text] [Related]
18. Monitoring the concentration of flowing pharmaceutical powders in a tableting feed frame.
Gosselin R; Durão P; Abatzoglou N; Guay JM
Pharm Dev Technol; 2017 Sep; 22(6):699-705. PubMed ID: 26507901
[TBL] [Abstract][Full Text] [Related]
19. Mechanistic basis for the effects of process parameters on quality attributes in high shear wet granulation.
Badawy SI; Narang AS; LaMarche K; Subramanian G; Varia SA
Int J Pharm; 2012 Dec; 439(1-2):324-33. PubMed ID: 22981985
[TBL] [Abstract][Full Text] [Related]
20. The effects of unintentional and intentional process disturbances on tablet quality during long continuous manufacturing runs.
Taipale-Kovalainen K; Karttunen AP; Niinikoski H; Ketolainen J; Korhonen O
Eur J Pharm Sci; 2019 Mar; 129():10-20. PubMed ID: 30550973
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]