These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 2638665)

  • 1. Comparative study of capillary and arterial, blood gas values in plastic and glass syringes at various intervals in normal and asthmatic subjects.
    Mathur US; Manchanda A; Singh V; Rishi JP; Athaiya V
    Indian J Chest Dis Allied Sci; 1989; 31(4):247-50. PubMed ID: 2638665
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of syringe material, sample storage time, and temperature on blood gases and oxygen saturation in arterialized human blood samples.
    Knowles TP; Mullin RA; Hunter JA; Douce FH
    Respir Care; 2006 Jul; 51(7):732-6. PubMed ID: 16800906
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test.
    Smeenk FW; Janssen JD; Arends BJ; Harff GA; van den Bosch JA; Schönberger JP; Postmus PE
    Eur Respir J; 1997 Apr; 10(4):910-3. PubMed ID: 9150334
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of arterial blood sampling using the B 109 syringe (radiometer).
    Fassoulaki A; Athanassiou E
    Acta Anaesthesiol Belg; 1986; 37(4):271-3. PubMed ID: 3105223
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of syringe material and needle size on the minimum plunger-displacement pressure of arterial blood gas syringes.
    Ansel GM; Douce FH
    Respir Care; 1982 Feb; 27(2):147-51. PubMed ID: 10315159
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of capillary blood gas estimation in neonates.
    Saili A; Dutta AK; Sarna MS
    Indian Pediatr; 1992 May; 29(5):567-70. PubMed ID: 1500104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Changes in gasometric values as a result of plastic syringes refrigeration].
    Guevara Sanz JM; Conde Anguita A; Requena Castillo MD
    Rev Enferm; 2002 Jan; 25(1):8-12. PubMed ID: 13677765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of syringe type and storage temperature on results of blood gas analysis in arterial blood of horses.
    Picandet V; Jeanneret S; Lavoie JP
    J Vet Intern Med; 2007; 21(3):476-81. PubMed ID: 17552454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A "micro" technique for arterial blood gas analysis].
    Schlumpf V; Ragaz A; Keller R
    Schweiz Med Wochenschr; 1981 Jan; 111(2):42-5. PubMed ID: 7280615
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of fetal acidemia at birth from a remote umbilical arterial blood gas analysis.
    Chauhan SP; Cowan BD; Meydrech EF; Magann EF; Morrison JC; Martin JN
    Am J Obstet Gynecol; 1994 Jun; 170(6):1705-9; discussion 1709-12. PubMed ID: 8203430
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stability of an analgesic-sedative combination in glass and plastic single-dose syringes.
    Conklin CA; Kerege JF; Christensen JM
    Am J Hosp Pharm; 1985 Feb; 42(2):339-42. PubMed ID: 3976682
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparative study of plastic (polypropylene) and glass syringes in blood-gas analysis.
    Evers W; Racz GB; Levy AA
    Anesth Analg; 1972; 51(1):92-7. PubMed ID: 5061730
    [No Abstract]   [Full Text] [Related]  

  • 13. Effects of syringe material and temperature and duration of storage on the stability of equine arterial blood gas variables.
    Deane JC; Dagleish MP; Benamou AE; Wolf BT; Marlin D
    Vet Anaesth Analg; 2004 Oct; 31(4):250-7. PubMed ID: 15509289
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Source of error on A-aDO2 calculated from blood stored in plastic and glass syringes.
    Wu EY; Barazanji KW; Johnson RL
    J Appl Physiol (1985); 1997 Jan; 82(1):196-202. PubMed ID: 9029216
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of post-sampling analysis time, type of blood samples and collection tubes on values of blood gas testing.
    Smajić J; Kadić D; Hasić S; Serdarević N
    Med Glas (Zenica); 2015 Aug; 12(2):108-12. PubMed ID: 26276646
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fiber-optic chemical sensors (Gas-Stat) for blood gas monitoring during hypothermic extracorporeal circulation.
    Gøthgen IH; Siggaard-Andersen O; Rasmussen JP; Wimberley PD; Fogh-Andersen N
    Scand J Clin Lab Invest Suppl; 1987; 188():27-9. PubMed ID: 3502429
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stability of pO2, pCO2 and pH in heparinized whole blood samples: influence of storage temperature with regard to leukocyte count and syringe material.
    Schmidt C; Müller-Plathe O
    Eur J Clin Chem Clin Biochem; 1992 Nov; 30(11):767-73. PubMed ID: 1489849
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Influence of the syringe materials on arterial blood gas measurements].
    Toda H; Murakawa M; Arai T; Hatano Y; Mori K
    Masui; 1987 May; 36(5):694-8. PubMed ID: 2958645
    [No Abstract]   [Full Text] [Related]  

  • 19. Use of glass capillaries avoids the time changes in high blood PO(2) observed with plastic syringes.
    d'Ortho MP; Delclaux C; Zerah F; Herigault R; Adnot S; Harf A
    Chest; 2001 Nov; 120(5):1651-4. PubMed ID: 11713149
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Atropine and ephedrine adsorption to syringe plastic.
    Lewis B; Jarvi E; Cady P
    AANA J; 1994 Jun; 62(3):257-60. PubMed ID: 7725865
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.